Reproducibility study of left ventricular measurements with breath-hold cine MRI using a semiautomated volumetric image analysis program

被引:23
作者
Butler, SP [1 ]
McKay, E [1 ]
Paszkowski, AL [1 ]
Quinn, RJ [1 ]
Shnier, RC [1 ]
Donovan, JT [1 ]
机构
[1] St George Hosp, Div Med Imaging, Sydney, NSW 2217, Australia
来源
JMRI-JOURNAL OF MAGNETIC RESONANCE IMAGING | 1998年 / 8卷 / 02期
关键词
cardiac MR; semiautomated; quantitative; analysis; reproducibility;
D O I
10.1002/jmri.1880080230
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
The reproducibility of a semiautomated method of volumetric analysis allowing estimates of left ventricular (LV) parameters in approximately 5 minutes of analysis time is reported. Twenty normal volunteers underwent cine breath-hold cardiac MRI on two occasions with two observers using this new semiautomated method to estimate LV parameters. Reproducibility of this technique was comparable to published data with a variability of less than approximately 10% for all LV parameters calculated, Using;this technique, the 95% confidence limits for change for left ventricular end diastolic volume (LVEDV) = +/- 15 mi, left ventricular end systolic volume (LVESV) = +/- 8 mi, LV mass = +/- 24 g. and left ventricular ejection fraction (LVEF) = +/- 6%. This new method also compared favorably to established manual methods. This new method permits estimation of LV parameters with acceptable reproducibility in a time that may permit routine quantitation of cardiac MR studies.
引用
收藏
页码:467 / 472
页数:6
相关论文
共 19 条
[1]   CINEANGIOGRAPHY OF THE HEART IN A SINGLE BREATH HOLD WITH A SEGMENTED TURBOFLASH SEQUENCE [J].
ATKINSON, DJ ;
EDELMAN, RR .
RADIOLOGY, 1991, 178 (02) :357-360
[2]   NONINVASIVE DETERMINATION OF LEFT-VENTRICULAR OUTPUT AND WALL STRESS IN VOLUME OVERLOAD AND IN MYOCARDIAL-DISEASE BY CINE MAGNETIC-RESONANCE-IMAGING [J].
AUFFERMANN, W ;
WAGNER, S ;
HOLT, WW ;
BUSER, PT ;
KIRCHER, B ;
SCHILLER, NB ;
LIM, TH ;
WOLFE, CL ;
HIGGINS, CB .
AMERICAN HEART JOURNAL, 1991, 121 (06) :1750-1758
[3]   AUTOMATED MYOCARDIAL EDGE-DETECTION FROM BREATH-HOLD CINE-MR IMAGES - EVALUATION OF LEFT-VENTRICULAR VOLUMES AND MASS [J].
BALDY, C ;
DOUEK, P ;
CROISILLE, P ;
MAGNIN, IE ;
REVEL, D ;
AMIEL, M .
MAGNETIC RESONANCE IMAGING, 1994, 12 (04) :589-598
[4]   LEFT-VENTRICULAR VOLUME MEASUREMENT USING CARDIAC AXIS NUCLEAR-MAGNETIC-RESONANCE IMAGING - VALIDATION BY CALIBRATED VENTRICULAR ANGIOGRAPHY [J].
CRANNEY, GB ;
LOTAN, CS ;
DEAN, L ;
BAXLEY, W ;
BOUCHARD, A ;
POHOST, GM .
CIRCULATION, 1990, 82 (01) :154-163
[5]  
CRANNEY GB, 1991, CIRCULATION S1, V84, P216
[6]   AUTOMATED MYOCARDIAL EDGE-DETECTION ON MR-IMAGES - ACCURACY IN CONSECUTIVE SUBJECTS [J].
FLEAGLE, SR ;
THEDENS, DR ;
STANFORD, W ;
THOMPSON, BH ;
WESTON, JM ;
PATEL, PP ;
SKORTON, DJ .
JMRI-JOURNAL OF MAGNETIC RESONANCE IMAGING, 1993, 3 (05) :738-741
[7]   REPRODUCIBILITY OF LEFT-VENTRICULAR VOLUMES BY TWO-DIMENSIONAL ECHOCARDIOGRAPHY [J].
GORDON, EP ;
SCHNITTGER, I ;
FITZGERALD, PJ ;
WILLIAMS, P ;
POPP, RL .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1983, 2 (03) :506-513
[8]   ESTIMATION OF HUMAN MYOCARDIAL MASS WITH MR IMAGING [J].
KATZ, J ;
MILLIKEN, MC ;
STRAYGUNDERSEN, J ;
BUJA, LM ;
PARKEY, RW ;
MITCHELL, JH ;
PESHOCK, RM .
RADIOLOGY, 1988, 169 (02) :495-498
[9]   SPONTANEOUS CHANGES IN LEFT-VENTRICULAR FUNCTION BETWEEN SEQUENTIAL STUDIES [J].
MCANULTY, JH ;
KREMKAU, EL ;
ROSCH, J ;
HATTENHAUER, MT ;
RAHIMTOOLA, SH .
AMERICAN JOURNAL OF CARDIOLOGY, 1974, 34 (01) :23-28
[10]   QUANTIFICATION OF LEFT-VENTRICULAR MYOCARDIAL MASS IN HUMANS BY NUCLEAR MAGNETIC-RESONANCE IMAGING [J].
OSTRZEGA, E ;
MADDAHI, J ;
HONMA, H ;
CRUES, JV ;
RESSER, KJ ;
CHARUZI, Y ;
BERMAN, DS .
AMERICAN HEART JOURNAL, 1989, 117 (02) :444-452