Accuracy of 64-MDCT in the diagnosis of ischemic heart disease

被引:230
作者
Nikolaou, K
Knez, A
Rist, C
Wintersperger, BJ
Leber, A
Johnson, T
Reiser, MF
Becker, CR
机构
[1] Univ Munich, Klinikum Grosshadern, Univ Hosp, Dept Clin Radiol, D-81377 Munich, Germany
[2] Grosshadern Ludwig Maximilians Univ, Univ Hosp, Dept Cardiol, Munich, Germany
关键词
CT angiography; CT coronary arteriography; MDCT;
D O I
10.2214/AJR.05.1697
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
OBJECTIVE. The aim of this study was to evaluate the potential clinical value of a new generation of 64-MDCT systems with that of invasive coronary angiography in the diagnosis of coronary artery disease (CAD). SUBJECTS AND METHODS. Seventy-two consecutive patients with known or suspected CAD underwent both 64-MDCT and quantitative coronary angiography (QCA). A CT system with acquisition of 64 slices per gantry rotation was used with a spatial resolution of 0.4 x 0.4 x 0.4 mm and a gantry rotation time of 330 milliseconds. Sensitivity, specificity, and diagnostic accuracy of 64-MDCT in the detection or exclusion of CAD were evaluated on both a per patient and a per segment basis. RESULTS. Sixty-eight of 72 coronary CT angiograms (CTAs) (94%) were of diagnostic image quality. QCA showed significant CAD (i.e., one or more stenoses in > 50%) in 57% (39/68) and nonsignificant disease or healthy CTAs in 43% (29/68) of the patients. Sensitivity, specificity, and the negative predictive value (NPV) of 64-MDCT per patient were 97%, 79%, and 96%, respectively. Per segment, 923 of 1,020 coronary artery segments were assessable (90%). For the detection of stenoses of more than 50% and more than 75% per segment, 64-MDCT showed a sensitivity of 82% and 86%, respectively. Per segment, specificity and NPV were as high as 95% and 97%, respectively. CONCLUSION. In clinical routine, coronary CTA will primarily be used for risk stratification on a per patient basis. In the present study, coronary 64-MDCT showed a high diagnostic accuracy on both per patient and per segment analyses.
引用
收藏
页码:111 / 117
页数:7
相关论文
共 21 条
[1]  
Achenbach S, 2000, CIRCULATION, V102, P2823
[2]   Detection of coronary artery stenoses with multislice helical CT angiography [J].
Becker, CR ;
Knez, A ;
Leber, A ;
Treede, H ;
Ohnesorge, B ;
Schoepf, UJ ;
Reiser, MF .
JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 2002, 26 (05) :750-755
[3]   Intravenous contrast material administration at 16-detector row helical CT coronary angiography: Test bolus versus bolus-tracking technique [J].
Cademartiri, F ;
Nieman, K ;
van der Lugt, A ;
Raaijmakers, RH ;
Mollet, N ;
Pattynama, PMT ;
de Feyter, PJ ;
Krestin, GP .
RADIOLOGY, 2004, 233 (03) :817-823
[4]   INTRATHORACIC SPATIAL LOCATION OF SPECIFIED CORONARY SEGMENTS ON THE NORMAL HUMAN-HEART - APPLICATIONS IN QUANTITATIVE ARTERIOGRAPHY, ASSESSMENT OF REGIONAL RISK AND CONTRACTION, AND ANATOMIC DISPLAY [J].
DODGE, JT ;
BROWN, BG ;
BOLSON, EL ;
DODGE, HT .
CIRCULATION, 1988, 78 (05) :1167-1180
[5]   Performance evaluation of a 64-slice CT system with z-flying focal spot [J].
Flohr, T ;
Stierstorfer, K ;
Raupach, R ;
Ulzheimer, S ;
Bruder, H .
ROFO-FORTSCHRITTE AUF DEM GEBIET DER RONTGENSTRAHLEN UND DER BILDGEBENDEN VERFAHREN, 2004, 176 (12) :1803-1810
[6]   Predictive value of 16-slice multidetector spiral computed tomography to detect significant obstructive coronary artery disease in patients at high risk for coronary artery disease - Patient-versus segment-based analysis [J].
Hoffmann, U ;
Moselewski, F ;
Cury, RC ;
Ferencik, M ;
Jang, IK ;
Diaz, LJ ;
Abbara, S ;
Brady, TJ ;
Achenbach, S .
CIRCULATION, 2004, 110 (17) :2638-2643
[7]   Radiation exposure during cardiac CT: Effective doses at multi-detector row CT and electron-beam CT [J].
Hunold, P ;
Vogt, FM ;
Schmermund, A ;
Debatin, JF ;
Kerkhoff, G ;
Budde, T ;
Erbel, R ;
Ewen, K ;
Barkhausen, J .
RADIOLOGY, 2003, 226 (01) :145-152
[8]   Multislice helical CT of the heart with retrospective ECG gating: reduction of radiation exposure by ECG-controlled tube current modulation [J].
Jakobs, TF ;
Becker, CR ;
Ohnesorge, B ;
Flohr, T ;
Suess, C ;
Schoepf, UJ ;
Reiser, MF .
EUROPEAN RADIOLOGY, 2002, 12 (05) :1081-1086
[9]   Diagnostic accuracy of multidetector computed tomography coronary angiography in with angiographically proven coronary artery disease patients [J].
Kuettner, A ;
Kopp, AF ;
Schroeder, S ;
Rieger, T ;
Brunn, J ;
Meisner, C ;
Heuschmid, M ;
Trabold, T ;
Burgstahler, C ;
Martensen, J ;
Schoebel, W ;
Selbmann, HK ;
Claussen, CD .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2004, 43 (05) :831-839
[10]   Diagnostic accuracy of noninvasive coronary imaging using 16-detector slice spiral computed tomography with 188 ms temporal resolution [J].
Kuettner, A ;
Beck, T ;
Drosch, T ;
Kettering, K ;
Heuschmid, M ;
Burgstahler, C ;
Claussen, CD ;
Kopp, AF ;
Schroeder, S .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2005, 45 (01) :123-127