Intravenous contrast material administration at 16-detector row helical CT coronary angiography: Test bolus versus bolus-tracking technique

被引:202
作者
Cademartiri, F
Nieman, K
van der Lugt, A
Raaijmakers, RH
Mollet, N
Pattynama, PMT
de Feyter, PJ
Krestin, GP
机构
[1] Erasmus Med Ctr, Dept Radiol, NL-3015 GD Rotterdam, Netherlands
[2] Erasmus Med Ctr, Dept Cardiol Thoraxctr, NL-3015 GD Rotterdam, Netherlands
关键词
aorta; CT; computed tomography (CT); contrast enhancement; coronary vessels; pulmonary arteries;
D O I
10.1148/radiol.2333030668
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: To compare test bolus and bolus-tracking techniques for intravenous contrast material administration at 16-detector row computed tomographic (CT) coronary angiography. Materials and Methods: This study had institutional review board approval, and patients gave informed consent. Thirty-eight patients (mean age, 60 years; three women) were randomized into two groups according to bolus timing technique: group 1 (20-mL test bolus with 100-mL main bolus) and group 2 (bolus tracking with 100-mL main bolus). All patients underwent electrocardiographygated 16-detector row CT coronary angiography with 12 detectors (collimation, 0.75 mm; rotation time, 420 msec). In group 1, test bolus peak attenuation was used as a delay, while in group 2, a + 100-HU threshold in ascending aorta triggered angiographic acquisition, with an additional 4-second delay for patient instruction. Attenuation was measured in the longitudinal direction throughout the examination in three main vessels: ascending aorta (region of interest [ROI]1), descending aorta ( ROI 2), and main pulmonary artery (ROI 3). Mean attenuation and slope of bolus geometry curve were calculated in each patient and ROI. Attenuation at origin of coronary arteries was measured. Student t test was used to compare results. Results: Mean scan delay was 6 seconds longer in group 2 (P<.05). Average attenuation values were 306.6 HU±44.0 (standard deviation) and 328.2 HU±58.6 (P>05) in ROI 1, 291.6 HU+/-45.1 and 326.4 HU+/-62.6 (P>.05) in ROI 2, and 354.7 HU+/-78.0 and 305.3 HU+/-71.4 (P<.05) in ROI 3 for groups 1 and 2, respectively. Average slope values were 5.8 and -0.8 (P<.05) in ROI 1, 7.7 and 0.7 (P<.05) in ROI 2, and -1.0 and -13.3 (P<.05) in ROI 3 for groups 1 and 2, respectively. Average attenuation values in left main, left anterior descending, and left circumflex arteries were higher in group 2 (P<.05); there were no differences (P>.05) between groups in right coronary artery. Conclusion: Bolus-tracking yields more homogeneous enhancement than does the test bolus technique. (C) RSNA, 2004.
引用
收藏
页码:817 / 823
页数:7
相关论文
共 21 条
  • [1] Achenbach S, 2000, CIRCULATION, V102, P2823
  • [2] Achenbach S, 2001, CIRCULATION, V103, P2535
  • [3] Aortic and hepatic peak enhancement at CT: Effect of contrast medium injection rate - Pharmacokinetic analysis and experimental porcine model
    Bae, KT
    Heiken, JP
    Brink, JA
    [J]. RADIOLOGY, 1998, 206 (02) : 455 - 464
  • [4] Parameters affecting bolus geometry in CTA: A review
    Cademartiri, F
    van der Lugt, A
    Luccichenti, G
    Pavone, P
    Krestin, GP
    [J]. JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 2002, 26 (04) : 598 - 607
  • [5] Improved uniformity of aortic enhancement with customized contrast medium injection protocols at CT angiography
    Fleischmann, D
    Rubin, GD
    Bankier, AA
    Hittmair, K
    [J]. RADIOLOGY, 2000, 214 (02) : 363 - 371
  • [6] New technical developments in multislice CT - Part 1: Approaching isotropic resolution with sub-millimeter 16-slice scanning
    Flohr, T
    Stierstorfer, K
    Bruder, H
    Simon, J
    Schaller, S
    [J]. ROFO-FORTSCHRITTE AUF DEM GEBIET DER RONTGENSTRAHLEN UND DER BILDGEBENDEN VERFAHREN, 2002, 174 (07): : 839 - 845
  • [7] New technical developments in multislice CT, part 2: Sub-millimeter 16-slice scanning and increased gantry rotation speed for cardiac Imaging
    Flohr, T
    Bruder, H
    Stierstorfer, K
    Simon, J
    Schaller, S
    Ohnesorge, B
    [J]. ROFO-FORTSCHRITTE AUF DEM GEBIET DER RONTGENSTRAHLEN UND DER BILDGEBENDEN VERFAHREN, 2002, 174 (08): : 1022 - 1027
  • [8] Visualization of coronary arteries in CT as assessed by a new 16 slice technology and reduced gantry rotation time:: first experiences
    Heuschmid, M
    Küttner, A
    Flohr, T
    Wildberger, JE
    Lell, M
    Kopp, AF
    Schröder, S
    Baum, U
    Schaller, S
    Hartung, A
    Ohnesorge, B
    Claussen, CD
    [J]. ROFO-FORTSCHRITTE AUF DEM GEBIET DER RONTGENSTRAHLEN UND DER BILDGEBENDEN VERFAHREN, 2002, 174 (06): : 721 - 724
  • [9] Optimized enhancement in helical CT: Experiences with a real-time bolus tracking system in 628 patients
    Kirchner, J
    Kickuth, R
    Laufer, U
    Noack, M
    Liermann, D
    [J]. CLINICAL RADIOLOGY, 2000, 55 (05) : 368 - 373
  • [10] Usefulness of multislice spiral computed tomography angiography for determination of coronary artery stenoses
    Knez, A
    Becker, CR
    Leber, A
    Ohnesorge, B
    Becker, A
    White, C
    Haberl, R
    Reiser, MF
    Steinbeck, G
    [J]. AMERICAN JOURNAL OF CARDIOLOGY, 2001, 88 (10) : 1191 - +