Improved quantification of left ventricular mass based on endocardial and epicardial surface detection with real time three dimensional echocardiography

被引:54
作者
Caiani, EG
Corsi, C
Sugeng, L
MacEneaney, P
Weinert, L
Mor-Avi, V
Lang, RM
机构
[1] Univ Chicago, Med Ctr, Noninvas Cardiac Imaging Lab, Chicago, IL 60637 USA
[2] Univ Bologna, DEIS, Bologna, Italy
[3] Politecn Milan, Dipartimento Bioingn, I-20133 Milan, Italy
关键词
D O I
10.1136/hrt.2005.060889
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Objective: To develop a technique for volumetric analysis of real time three dimensional echocardiography ( RT3DE) data aimed at quantifying left ventricular ( LV) mass and to validate the technique against magnetic resonance (MR) assumed as the reference standard. Design: RT3DE, which has recently become widely available, provides dynamic pyramidal data structures that encompass the entire heart and allows four dimensional assessment of cardiac anatomy and function. However, analysis techniques for the quantification of LV mass from RT3DE data are fundamentally two dimensional, rely on geometric modelling, and do not fully exploit the volumetric information contained in RT3DE datasets. Twenty one patients underwent two dimensional echocardiography (2DE), RT3DE, and cardiac MR. LV mass was measured from 2DE and MR images by conventional techniques. RT3DE data were analysed to semiautomatically detect endocardial and epicardial LV surfaces by the level set approach. From the detected surfaces, LV mass was computed directly in the three dimensional space as voxel counts. Results: RT3DE measurement was feasible in 19 of 21 patients and resulted in higher correlation with MR (r = 0.96) than did 2DE ( r = 0.79). RT3DE measurements also had a significantly smaller bias (-2.1 g) and tighter limits of agreement (2SD = +/- 23 g) with MR than did the 2DE values ( bias ( 2SD) -34.9 ( 50) g). Additionally, interobserver variability of RT3DE (12.5%) was significantly lower than that of 2DE (24.1%). Conclusions: Direct three dimensional model independent LV mass measurement from RT3DE images is feasible in the clinical setting and provides fast and accurate assessment of LV mass, superior to the two dimensional analysis techniques.
引用
收藏
页码:213 / 219
页数:7
相关论文
共 31 条
[1]   LEFT-VENTRICULAR MASS AND VOLUME MASS RATIO DETERMINED BY TWO-DIMENSIONAL ECHOCARDIOGRAPHY IN NORMAL ADULTS [J].
BYRD, BF ;
WAHR, D ;
WANG, YS ;
BOUCHARD, A ;
SCHILLER, NB .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1985, 6 (05) :1021-1025
[2]   Three-dimensional echocardiographic measurement of left ventricular mass: Comparison with magnetic resonance imaging and two-dimensional echocardiographic determinations in man [J].
Chuang, ML ;
Beaudin, RA ;
Riley, MF ;
Mooney, MG ;
Manning, WJ ;
Douglas, PS ;
Hibberd, MG .
INTERNATIONAL JOURNAL OF CARDIAC IMAGING, 2000, 16 (05) :347-357
[3]   Left ventricular volume estimation for real-time three-dimensional echocardiography [J].
Corsi, C ;
Saracino, G ;
Sarti, A ;
Lamberti, C .
IEEE TRANSACTIONS ON MEDICAL IMAGING, 2002, 21 (09) :1202-1208
[4]   ECHOCARDIOGRAPHIC DETERMINATION OF LEFT-VENTRICULAR MASS IN MAN - ANATOMIC VALIDATION OF METHOD [J].
DEVEREUX, RB ;
REICHEK, N .
CIRCULATION, 1977, 55 (04) :613-618
[5]   Efficient model-based quantification of left ventricular function in 3-D echocardiography [J].
Gérard, O ;
Billon, AC ;
Rouet, JM ;
Jacob, M ;
Fradkin, M ;
Allouche, C .
IEEE TRANSACTIONS ON MEDICAL IMAGING, 2002, 21 (09) :1059-1068
[6]   THE PROGNOSTIC ROLE OF LEFT-VENTRICULAR HYPERTROPHY IN PATIENTS WITH OR WITHOUT CORONARY-ARTERY DISEASE [J].
GHALI, JK ;
LIAO, YL ;
SIMMONS, B ;
CASTANER, A ;
CAO, GC ;
COOPER, RS .
ANNALS OF INTERNAL MEDICINE, 1992, 117 (10) :831-836
[7]   Freehand three-dimensional echocardiography for measurement of left ventricular mass: In vivo anatomic validation using explanted human hearts [J].
Gopal, AS ;
Schnellbaecher, MJ ;
Shen, ZQ ;
Akinboboye, OO ;
Sapin, PM ;
King, DL .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1997, 30 (03) :802-810
[8]   3-DIMENSIONAL ECHOCARDIOGRAPHY - IN-VITRO AND IN-VIVO VALIDATION OF LEFT-VENTRICULAR MASS AND COMPARISON WITH CONVENTIONAL ECHOCARDIOGRAPHIC METHODS [J].
GOPAL, AS ;
KELLER, AM ;
SHEN, ZQ ;
SAPIN, PM ;
SCHROEDER, KM ;
KING, DL ;
KING, DL .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1994, 24 (02) :504-513
[9]   QUANTITATION OF HUMAN LEFT-VENTRICULAR MASS - AND VOLUME BY TWO-DIMENSIONAL ECHOCARDIOGRAPHY - INVITRO ANATOMIC VALIDATION [J].
HELAK, JW ;
REICHEK, N .
CIRCULATION, 1981, 63 (06) :1398-1407
[10]   Reproducibility and accuracy of echocardiographic measurements of left ventricular parameters using real-time three-dimensional echocardiography [J].
Jenkins, C ;
Bricknell, K ;
Hanekom, L ;
Marwick, TH .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2004, 44 (04) :878-886