Significance of background optical properties, time-resolved information and optode arrangement in diffuse optical imaging of term neonates

被引:30
作者
Heiskala, J. [1 ,2 ]
Hiltunen, P. [2 ]
Nissila, I. [2 ,3 ]
机构
[1] Univ Helsinki, Cent Hosp, BioMag Lab, HUSLAB, FI-00029 Helsinki, Finland
[2] Aalto Univ, Dept Biomed Engn & Computat Sci, FI-02015 Espoo, Finland
[3] Univ Helsinki, Inst Biomed, FI-00014 Hy, Finland
基金
芬兰科学院;
关键词
NEAR-INFRARED SPECTROSCOPY; NON-SCATTERING REGIONS; HUMAN BRAIN-FUNCTION; PHOTON MIGRATION; FREQUENCY-DOMAIN; INFANT BRAIN; ADULT HEAD; NONSCATTERING REGIONS; RADIATIVE-TRANSFER; LIGHT-PROPAGATION;
D O I
10.1088/0031-9155/54/3/005
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
The significance of accurate knowledge of background optical properties and time-resolved information in reconstructing images of hemodynamic changes in the neonatal brain from diffuse optical imaging data was studied using Monte Carlo (MC) simulation. A segmented anatomical magnetic resonance (MR) image and literature-derived optical properties for each tissue type were used to create a voxel-based anatomical model. Small absorbing perturbations were introduced into the anatomical model to simulate localized hemodynamic responses related to brain activation. Perturbation MC (pMC) was used as the primary method of image reconstruction. For comparison, reconstructions were also performed using the finite element method (FEM) to solve the diffusion approximation (DA) to the radiative transfer equation (RTE). The effect of optode layout was investigated using three different grids. Of the factors studied, the density of the optode grid was found to have the greatest effect on image quality. The use of time-resolved information significantly improved the spatial accuracy with all optode grids. Adequate knowledge and modeling of the optical properties of the background was found to significantly improve the spatial accuracy of the reconstructed images and make the recovery of contrast of absorption changes more consistent over simplified modeling. Localization accuracy of small perturbations was found to be 2-3 mm with accurate a priori knowledge of the background optical properties, when a grid with high optode density (> 1 optode cm(-2)) was used.
引用
收藏
页码:535 / 554
页数:20
相关论文
共 57 条
[1]   A FINITE-ELEMENT APPROACH FOR MODELING PHOTON TRANSPORT IN TISSUE [J].
ARRIDGE, SR ;
SCHWEIGER, M ;
HIRAOKA, M ;
DELPY, DT .
MEDICAL PHYSICS, 1993, 20 (02) :299-309
[2]   PHOTON-MEASUREMENT DENSITY-FUNCTIONS .1. ANALYTICAL FORMS [J].
ARRIDGE, SR .
APPLIED OPTICS, 1995, 34 (31) :7395-7409
[3]   Optical tomography in medical imaging [J].
Arridge, SR .
INVERSE PROBLEMS, 1999, 15 (02) :R41-R93
[4]   Nonuniqueness in diffusion-based optical tomography [J].
Arridge, SR ;
Lionheart, WRB .
OPTICS LETTERS, 1998, 23 (11) :882-884
[5]  
Bazaraa MS., 2013, Nonlinear programming: theory and algorithms
[6]  
Bjorck A, 1996, NUMERICAL METHODS LE, DOI [10.1137/1.9781611971484, DOI 10.1137/1.9781611971484]
[7]   Simulation study of magnetic resonance imaging-guided cortically constrained diffuse optical tomography of human brain function [J].
Boas, DA ;
Dale, AM .
APPLIED OPTICS, 2005, 44 (10) :1957-1968
[8]   Improving the diffuse optical imaging spatial resolution of the cerebral hemodynamic response to brain activation in humans [J].
Boas, DA ;
Chen, K ;
Grebert, D ;
Franceschini, MA .
OPTICS LETTERS, 2004, 29 (13) :1506-1508
[9]   Three dimensional Monte Carlo code for photon migration through complex heterogeneous media including the adult human head [J].
Boas, DA ;
Culver, JP ;
Stott, JJ ;
Dunn, AK .
OPTICS EXPRESS, 2002, 10 (03) :159-170
[10]   A novel method for fast imaging of brain function, non-invasively, with light [J].
Chance, B ;
Anday, E ;
Nioka, S ;
Zhou, S ;
Hong, L ;
Worden, K ;
Li, C ;
Murray, T ;
Ovetsky, Y ;
Pidikiti, D ;
Thomas, R .
OPTICS EXPRESS, 1998, 2 (10) :411-423