Reducing the thrombogenicity of ion-selective electrode membranes through the use of a silicone-modified segmented polyurethane

被引:24
作者
Berrocal, MJ
Badr, IHA
Gao, DO
Bachas, LG [1 ]
机构
[1] Univ Kentucky, Dept Chem, Lexington, KY 40506 USA
[2] Univ Kentucky, Ctr Membrane Sci, Lexington, KY 40506 USA
[3] Univ Kentucky, Dept Mech Engn, Lexington, KY 40506 USA
[4] Univ Kentucky, Ctr Biomed Engn, Lexington, KY 40506 USA
关键词
D O I
10.1021/ac010375i
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
The susceptibility of segmented polyurethanes (SPUs) to in vivo oxidative cleavage and hydrolysis constitutes a drawback in the use of these materials in the fabrication of implantable devices. The introduction of poly(dimethylsiloxane) (PDMS) groups into the polymer main chain has been previously reported to enhance the stability of SPUs. Herein, we evaluated the use of BioSpan-S, a silicone-modified SPU, in the design of membranes for cation-selective electrodes. The resulting electrodes exhibited good potentiometric response with all of the tested ionophores (valinomycin, sodium ionophore X, and nonactin). The obtained selectivity coefficients meet the selectivity requirements for the determination of sodium and potassium in blood. Moreover, as reflected by SEM studies, membranes prepared with BioSpan-S showed less adhesion of platelets than membranes prepared with conventional poly(vinyl chloride) (PVC). These results lead to the conclusion that BioSpan-S would be an appropriate candidate for the fabrication of implantable ion-selective electrodes.
引用
收藏
页码:5328 / 5333
页数:6
相关论文
共 45 条
[1]   Characterization of photopolymerized decyl methacrylate as a membrane matrix for ion-selective electrodes [J].
Ambrose, TM ;
Meyerhoff, ME .
ELECTROANALYSIS, 1996, 8 (12) :1095-1100
[2]  
ANDERSON J M, 1985, Critical Reviews in Biocompatibility, V1, P111
[3]   Ion sensors: current limits and new trends [J].
Bakker, E ;
Diamond, D ;
Lewenstam, A ;
Pretsch, E .
ANALYTICA CHIMICA ACTA, 1999, 393 (1-3) :11-18
[4]   Carrier-based ion-selective electrodes and bulk optodes. 1. General characteristics [J].
Bakker, E ;
Buhlmann, P ;
Pretsch, E .
CHEMICAL REVIEWS, 1997, 97 (08) :3083-3132
[5]   PHOTOCURABLE POLYMER MATRICES FOR POTASSIUM-SENSITIVE ION-SELECTIVE ELECTRODE MEMBRANES [J].
BRATOV, A ;
ABRAMOVA, N ;
MUNOZ, J ;
DOMINGUEZ, C ;
ALEGRET, S ;
BARTROLI, J .
ANALYTICAL CHEMISTRY, 1995, 67 (19) :3589-3595
[6]   Effect of surface-attached heparin on the response of potassium-selective electrodes [J].
Brooks, HA ;
Allen, JR ;
Feldhoff, PW ;
Bachas, LG .
ANALYTICAL CHEMISTRY, 1996, 68 (08) :1439-1443
[7]   Carrier-based ion-selective electrodes and bulk optodes. 2. Ionophores for potentiometric and optical sensors [J].
Buhlmann, P ;
Pretsch, E ;
Bakker, E .
CHEMICAL REVIEWS, 1998, 98 (04) :1593-1687
[8]   SODIUM-SELECTIVE POLYMERIC MEMBRANE ELECTRODES BASED ON CALIX[4]ARENE IONOPHORES [J].
CADOGAN, AM ;
DIAMOND, D ;
SMYTH, MR ;
DEASY, M ;
MCKERVEY, MA ;
HARRIS, SJ .
ANALYST, 1989, 114 (12) :1551-1554
[9]   ELECTROCHEMICAL PERFORMANCE, BIOCOMPATIBILITY, AND ADHESION OF NEW POLYMER MATRICES FOR SOLID-STATE ION SENSORS [J].
CHA, GS ;
LIU, D ;
MEYERHOFF, ME ;
CANTOR, HC ;
MIDGLEY, AR ;
GOLDBERG, HD ;
BROWN, RB .
ANALYTICAL CHEMISTRY, 1991, 63 (17) :1666-1672
[10]   POTENTIOMETRIC ION-SELECTIVE AND BIO-SELECTIVE ELECTRODES BASED ON ASYMMETRIC CELLULOSE-ACETATE MEMBRANES [J].
CHA, GS ;
MEYERHOFF, ME .
TALANTA, 1989, 36 (1-2) :271-278