Reducing the thrombogenicity of ion-selective electrode membranes through the use of a silicone-modified segmented polyurethane

被引:24
作者
Berrocal, MJ
Badr, IHA
Gao, DO
Bachas, LG [1 ]
机构
[1] Univ Kentucky, Dept Chem, Lexington, KY 40506 USA
[2] Univ Kentucky, Ctr Membrane Sci, Lexington, KY 40506 USA
[3] Univ Kentucky, Dept Mech Engn, Lexington, KY 40506 USA
[4] Univ Kentucky, Ctr Biomed Engn, Lexington, KY 40506 USA
关键词
D O I
10.1021/ac010375i
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
The susceptibility of segmented polyurethanes (SPUs) to in vivo oxidative cleavage and hydrolysis constitutes a drawback in the use of these materials in the fabrication of implantable devices. The introduction of poly(dimethylsiloxane) (PDMS) groups into the polymer main chain has been previously reported to enhance the stability of SPUs. Herein, we evaluated the use of BioSpan-S, a silicone-modified SPU, in the design of membranes for cation-selective electrodes. The resulting electrodes exhibited good potentiometric response with all of the tested ionophores (valinomycin, sodium ionophore X, and nonactin). The obtained selectivity coefficients meet the selectivity requirements for the determination of sodium and potassium in blood. Moreover, as reflected by SEM studies, membranes prepared with BioSpan-S showed less adhesion of platelets than membranes prepared with conventional poly(vinyl chloride) (PVC). These results lead to the conclusion that BioSpan-S would be an appropriate candidate for the fabrication of implantable ion-selective electrodes.
引用
收藏
页码:5328 / 5333
页数:6
相关论文
共 45 条
[11]   ASYMMETRIC CELLULOSE-ACETATE MEMBRANE-BASED CARBONATE-SELECTIVE AND CHLORIDE-SELECTIVE ELECTRODES [J].
CHA, MJ ;
SHIN, JH ;
OH, BK ;
KIM, CY ;
CHA, GS ;
SHIN, DS ;
KIM, B .
ANALYTICA CHIMICA ACTA, 1995, 315 (03) :311-319
[12]   CARBOXYLATED POLY(VINYL CHLORIDE) AS A SUBSTRATE FOR ION SENSORS - EFFECTS OF NATIVE ION-EXCHANGE ON RESPONSES [J].
COSOFRET, VV ;
BUCK, RP ;
ERDOSY, M .
ANALYTICAL CHEMISTRY, 1994, 66 (21) :3592-3599
[13]   ELECTROANALYTICAL AND SURFACE CHARACTERIZATION OF ENCAPSULATED IMPLANTABLE MEMBRANE PLANAR MICROSENSORS [J].
COSOFRET, VV ;
ERDOSY, M ;
JOHNSON, TA ;
BELLINGER, DA ;
BUCK, RP ;
ASH, RB ;
NEUMAN, MR .
ANALYTICA CHIMICA ACTA, 1995, 314 (1-2) :1-11
[14]   ELECTROCHEMICAL CHARACTERIZATION OF AMINATED PVC-BASED ION-SELECTIVE MEMBRANES [J].
COSOFRET, VV ;
LINDNER, E ;
BUCK, RP ;
KUSY, RP ;
WHITLEY, JQ .
ELECTROANALYSIS, 1993, 5 (9-10) :725-730
[15]   Aliphatic polyurethane as a matrix for pH sensors: Effects of native sites and added proton carrier on electrical and potentiometric properties [J].
Cosofret, VV ;
Erdosy, M ;
Raleigh, JS ;
Johnson, TA ;
Neuman, MR ;
Buck, RP .
TALANTA, 1996, 43 (01) :143-151
[16]   THROMBOGENIC PROPERTIES OF UNTREATED AND POLY(ETHYLENE OXIDE)-MODIFIED POLYMERIC MATRICES USEFUL FOR PREPARING INTRAARTERIAL ION-SELECTIVE ELECTRODES [J].
ESPADASTORRE, C ;
MEYERHOFF, ME .
ANALYTICAL CHEMISTRY, 1995, 67 (18) :3108-3114
[17]   SELECTRODE - UNIVERSAL ION-SELECTIVE ELECTRODE .7. VALINOMYCIN-BASED POTASSIUM ELECTRODE WITH NONPOROUS POLYMER MEMBRANE AND SOLID-STATE INNER REFERENCE SYSTEM [J].
FIEDLER, U ;
RUZICKA, J .
ANALYTICA CHIMICA ACTA, 1973, 67 (01) :179-193
[18]   EVALUATION OF AN AMMONIUM IONOPHORE FOR USE IN POLY(VINYL CHLORIDE) MEMBRANE ION-SELECTIVE ELECTRODES - SOLVENT MEDIATOR EFFECTS [J].
GHAURI, MS ;
THOMAS, JDR .
ANALYST, 1994, 119 (11) :2323-2326
[19]  
Hahn CEW, 1998, ANALYST, V123, p57R
[20]   Methacrylate-acrylate based polymers of low plasticiser content for potassium ion-selective membranes [J].
Heng, LY ;
Hall, EAH .
ANALYTICA CHIMICA ACTA, 1996, 324 (01) :47-56