ELECTROANALYTICAL AND SURFACE CHARACTERIZATION OF ENCAPSULATED IMPLANTABLE MEMBRANE PLANAR MICROSENSORS

被引:12
作者
COSOFRET, VV
ERDOSY, M
JOHNSON, TA
BELLINGER, DA
BUCK, RP
ASH, RB
NEUMAN, MR
机构
[1] UNIV N CAROLINA,DEPT CHEM,CHAPEL HILL,NC 27599
[2] UNIV N CAROLINA,SCH MED,CHAPEL HILL,NC 27599
[3] N CAROLINA STATE UNIV,DEPT ELECT & COMP ENGN,RALEIGH,NC 27695
[4] CASE WESTERN RESERVE UNIV,METROHLTH MED CTR,DEPT OBSTET GYNECOL,CLEVELAND,OH 44109
基金
美国国家卫生研究院;
关键词
SENSORS; ENCAPSULATED POLYMERIC MEMBRANES; BIOCOMPATIBLE POLYMERS; IMPLANTABLE SENSORS;
D O I
10.1016/0003-2670(95)00260-7
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
The selective polymeric membranes of planar microsensors sensitive to inorganic analytes of biomedical interest (e.g., H+, K+), fabricated on a flexible polyimide (Kapton(R) DuPont) substrate using a combination of thin-film, thick-film and packaging technologies, were encapsulated with a biocompatible polymeric material such as poly(2-hydroxyethylmethacrylate) (poly-HEMA), The electroanalytical characteristics pf these sensors (linear activity ranges, slopes of the calibration curves, response times, membrane resistances, and selectivities) are not significantly different when compared with those of non-coated membrane sensors. The encapsulated membrane electrodes show improved analytical characteristics after exposure to whole blood samples for specified periods of time. The long-term stability of the membranes for in vivo use was investigated by the cage implant system; the membrane biostability and cell adhesion, at 1, 3, 7, and 14 days of subcutaneous implantation in Sprague-Dawley rats, were evaluated by scanning electron microscopy.
引用
收藏
页码:1 / 11
页数:11
相关论文
共 38 条
[1]   LIPOPHILIC SALTS AS MEMBRANE ADDITIVES AND THEIR INFLUENCE ON THE PROPERTIES OF MACROELECTRODES AND MICROELECTRODES BASED ON NEUTRAL CARRIERS [J].
AMMANN, D ;
PRETSCH, E ;
SIMON, W ;
LINDNER, E ;
BEZEGH, A ;
PUNGOR, E .
ANALYTICA CHIMICA ACTA, 1985, 171 (MAY) :119-129
[2]   THE EFFECTS OF POLYHEMA COATING ON THE ADHESION OF BACTERIA TO POLYMER MONOFILAMENTS [J].
BILBRUCK, J ;
HANLON, GW ;
MARTIN, GP .
INTERNATIONAL JOURNAL OF PHARMACEUTICS, 1993, 99 (2-3) :293-301
[3]  
CLARK LC, 1988, METHOD ENZYMOL, V137, P68
[4]   NEW NEUTRAL CARRIER-BASED H+ SELECTIVE-MEMBRANE ELECTRODES [J].
COSOFRET, VV ;
NAHIR, TM ;
LINDNER, E ;
BUCK, RP .
JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 1992, 327 (1-2) :137-146
[5]   MICROFABRICATED SENSOR ARRAYS SENSITIVE TO PH AND K+ FOR IONIC DISTRIBUTION MEASUREMENTS IN THE BEATING HEART [J].
COSOFRET, VV ;
ERDOSY, M ;
JOHNSON, TA ;
BUCK, RP ;
ASH, RB ;
NEUMAN, MR .
ANALYTICAL CHEMISTRY, 1995, 67 (10) :1647-1653
[6]   DESIGN OF IONOPHORE-FREE H+-SELECTIVE SOLVENT POLYMERIC MEMBRANES FOR FURTHER BIOMEDICAL APPLICATIONS [J].
COSOFRET, VV ;
LINDNER, E ;
BUCK, RP ;
KUSY, RP ;
WHITLEY, JQ .
JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 1993, 345 (1-2) :169-181
[7]   ELECTROANALYTICAL AND BIOCOMPATIBILITY STUDIES ON CARBOXYLATED POLY(VINYL CHLORIDE) MEMBRANES FOR MICROFABRICATED ARRAY SENSORS [J].
COSOFRET, VV ;
ERDOSY, M ;
BUCK, RP ;
KAO, WJ ;
ANDERSON, JM ;
LINDNER, E ;
NEUMAN, MR .
ANALYST, 1994, 119 (11) :2283-2292
[8]   PLANAR MICRO SENSORS FOR IN-VIVO MYOCARDIAL PH MEASUREMENTS [J].
COSOFRET, VV ;
LINDNER, E ;
JOHNSON, TA ;
NEUMAN, MR .
TALANTA, 1994, 41 (06) :931-938
[9]  
COSOFRET VV, IN PRESS POLYM MATER
[10]  
COSOFRET VV, 1994, ANAL LETT, V27, P15