Effect of first-dimension column film thickness on comprehensive two-dimensional gas chromatographic separation

被引:16
作者
Zhu, ZY [1 ]
Harynuk, J [1 ]
Górecki, T [1 ]
机构
[1] Univ Waterloo, Dept Chem, Waterloo, ON N2L 3G1, Canada
关键词
comprehensive two-dimensional gas chromatography; GC x GC; overloading; column diameter; film thickness; elution temperature;
D O I
10.1016/j.chroma.2005.09.018
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
In comprehensive two-dimensional gas chromatography (GC x GC), samples experience two-dimensional separation implemented by a modulator which helps preserve the first-dimension separation and facilitates the second-dimension separation by periodically collecting, focusing and launching the material from the primary column onto the secondary column with a different stationary phase. Column overloading in GC x GC is a considerable problem, aggravated by the fact that two columns are involved. Broad first-dimension peaks of an analyte help produce smaller fractions of the analyte in the second-dimension, reducing the chance of secondary column overloading. One of the means to generate broad peaks in the first-dimension is to use thick film primary columns. A series of primary columns of various film thickness were tested in the study, and the results indicate that when other conditions are kept constant, 1 mu m film columns often provide better resolution in both first and second-dimension but at the expense of a much longer separation time; 0.1 mu m is clearly inadequate for GC x GC separation; 0.5 and 0.25 mu m film columns seem to be the best compromises. (c) 2005 Elsevier B.V. All rights reserved.
引用
收藏
页码:17 / 24
页数:8
相关论文
共 13 条
[1]   Single-jet, single-stage cryogenic modulator for comprehensive two-dimensional gas chromatography (GC x GC) [J].
Adahchour, M ;
Beens, J ;
Brinkman, UAT .
ANALYST, 2003, 128 (03) :213-216
[2]   Simple, non-moving modulation interface for comprehensive two-dimensional gas chromatography [J].
Beens, J ;
Adahchour, M ;
Vreuls, RJJ ;
van Altena, K ;
Brinkman, UAT .
JOURNAL OF CHROMATOGRAPHY A, 2001, 919 (01) :127-132
[3]   Comprehensive two dimensional high-speed gas chromatography with chemometric analysis [J].
Bruckner, CA ;
Prazen, BJ ;
Synovec, RE .
ANALYTICAL CHEMISTRY, 1998, 70 (14) :2796-2804
[4]   Flow-switching device for comprehensive two-dimensional gas chromatography [J].
Bueno, PA ;
Seeley, JV .
JOURNAL OF CHROMATOGRAPHY A, 2004, 1027 (1-2) :3-10
[5]   Comprehensive two-dimensional gas chromatography:: a powerful and versatile analytical tool [J].
Dallüge, J ;
Beens, J ;
Brinkman, UAT .
JOURNAL OF CHROMATOGRAPHY A, 2003, 1000 (1-2) :69-108
[6]   The evolution of comprehensive two-dimensional gas chromatography (GC x GC) [J].
Górecki, T ;
Harynuk, J ;
Panic, O .
JOURNAL OF SEPARATION SCIENCE, 2004, 27 (5-6) :359-379
[7]   Overloading of the second-dimension column in comprehensive two-dimensional gas chromatography [J].
Harynuk, J ;
Górecki, T ;
de Zeeuw, J .
JOURNAL OF CHROMATOGRAPHY A, 2005, 1071 (1-2) :21-27
[8]   New liquid nitrogen cryogenic modulator for comprehensive two-dimensional gas chromatography [J].
Harynuk, J ;
Górecki, T .
JOURNAL OF CHROMATOGRAPHY A, 2003, 1019 (1-2) :53-63
[9]  
Kinghorn RM, 2000, HRC-J HIGH RES CHROM, V23, P245
[10]  
Ledford EB, 2000, HRC-J HIGH RES CHROM, V23, P202