Simultaneous determination of derivatized light aldehydes by microchip electrophoresis with electrochemical detection

被引:32
作者
Dossi, Nicolo [1 ]
Susmel, Sabina [1 ]
Toniolo, Rosanna [1 ]
Pizzariello, Andrea [1 ]
Bontempelli, Gino [1 ]
机构
[1] Univ Udine, Dept Chem Sci & Technol, I-33100 Udine, Italy
关键词
Aldehydes; Derivatization with 2,4-dinitrophenylhydrazine; Microchip capillary electrophoresis; Amperometric detection;
D O I
10.1016/j.chroma.2008.08.016
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
A method, based on microchip electrophoresis with electrochemical detection, has been developed for the simultaneous determination of light aliphatic aldehydes (acetaldehyde, propionaldehyde, butyraldehyde and hexylaldehyde) derivatized with 2,4-dinitrophenylhydrazine (DNPH). Optimal conditions for the derivatization reaction, providing recoveries of 70 +/- 1.8% for all analytes, were identified by application to real samples, consisting of vegetable oils enriched with known amounts of the aldehydes considered. DNPH hydrazones thus obtained in acetonitrile solution were added to the electrophoresis running medium consisting of a 15 mM borate buffer (pH 9.2) added with 25 mM of sodium dodecyl sulfate and 35% (v/v) of acetonitrile. Factors affecting both separation and electrochemical detection were examined and optimised, with best performance achieved by using the running medium above and applying a voltage of 2250V in both separation and electrokinetic injection. Under these optimal conditions, the target analytes could be separated and detected within 350 s by applying a detection potential of -1.0V (vs. Ag/AgCl) to the glassy carbon working electrode. The recorded peaks were well separated and characterized by good repeatability (RSD = 1.6-3.8%), high sensitivity and a wide linear range. Detection limits of 4.5, 6.6, 6.8,13.1 mu M were obtained for acetaldehyde-DNPH, propionaldehyde-DNPH, butyraldehyde-DNPH and hexylaldehyde-DNPH derivatives, respectively. (C) 2008 Elsevier B.V. All rights reserved.
引用
收藏
页码:169 / 174
页数:6
相关论文
共 38 条
[1]   DNA adducts from acetaldehyde: implications for alcohol-related carcinogenesis [J].
Brooks, PJ ;
Theruvathu, JA .
ALCOHOL, 2005, 35 (03) :187-193
[2]   Monitoring environmental pollutants by microchip capillary electrophoresis with electrochemical detection [J].
Chen, G ;
Lin, YH ;
Wang, J .
TALANTA, 2006, 68 (03) :497-503
[3]   High-performance liquid chromatographic peak identification of 2,4-dinitrophenylhydrazine derivatives of lipid peroxidation aldehydes by photodiode array detection [J].
Cordis, GA ;
Das, DK ;
Riedel, W .
JOURNAL OF CHROMATOGRAPHY A, 1998, 798 (1-2) :117-123
[4]   Food analysis on microfluidic devices using ultrasensitive carbon nanotubes detectors [J].
Crevillen, A. Gonzalez ;
Avila, Monica ;
Pumera, Martin ;
Gonzalez, Maria Cristina ;
Escarpa, Alberto .
ANALYTICAL CHEMISTRY, 2007, 79 (19) :7408-7415
[5]   Separation of carbonyl 2,4-dinitrophenylhydrazones by capillary electrochromatography with diode array detection [J].
Dabek-Zlotorzynska, E ;
Lai, EPC .
JOURNAL OF CHROMATOGRAPHY A, 1999, 853 (1-2) :487-496
[6]   Development of headspace solid-phase microextraction with on-fiber derivatization for determination of hexanal and heptanal in human blood [J].
Deng, CH ;
Li, N ;
Zhang, XM .
JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2004, 813 (1-2) :47-52
[7]   Investigation of volatile biomarkers in lung cancer blood using solid-phase microextraction and capillary gas chromatography-mass spectrometry [J].
Deng, CH ;
Zhang, XM ;
Li, N .
JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2004, 808 (02) :269-277
[8]   Rapid analysis of azo-dyes in food by microchip electrophoresis with electrochemical detection [J].
Dossi, Nicolo ;
Piccin, Evandro ;
Bontempelli, Gino ;
Carrilho, Emanuel ;
Wang, Joseph .
ELECTROPHORESIS, 2007, 28 (22) :4240-4246
[9]   A capillary electrophoresis microsystem for the rapid in-channel amperometric detection of synthetic dyes in food [J].
Dossi, Nicolo ;
Toniolo, Rosanna ;
Pizzariello, Andrea ;
Susmel, Sabina ;
Perennes, Frederic ;
Bontempelli, Gino .
JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 2007, 601 (1-2) :1-7
[10]   GLASS CHIPS FOR HIGH-SPEED CAPILLARY ELECTROPHORESIS SEPARATIONS WITH SUBMICROMETER PLATE HEIGHTS [J].
EFFENHAUSER, CS ;
MANZ, A ;
WIDMER, HM .
ANALYTICAL CHEMISTRY, 1993, 65 (19) :2637-2642