Electroluminescence based determination of the space charge limited field

被引:5
作者
Cao, Y [1 ]
Boggs, S [1 ]
机构
[1] Univ Connecticut, Elect Insulat Res Ctr, Storrs, CT 06269 USA
来源
2001 ANNUAL REPORT CONFERENCE ON ELECTRICAL INSULATION AND DIELECTRIC PHENOMENA | 2001年
关键词
D O I
10.1109/CEIDP.2001.963528
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
Determination of the space charge limited field is compromised by photon detection sensitivity. As a result, the experimental determined field is affected by the test frequency and by the photomultiplier dark count. The electroluminescence inception field determined with semicon needle is in good agreement with the space charge limited field measured using a guarded needle electrode, while metal needles with tip radii smaller than 5 mum lead to much greater predicted space charge limited field due to the much smaller light emitting volume. This electrode size effect is explained, and a correction method is proposed which results in a more accurate determination of the space charge limited field from electroluminescence measurements.
引用
收藏
页码:236 / 240
页数:5
相关论文