Commissioning and quality assurance of RapidArc radiotherapy delivery system

被引:255
作者
Ling, C. Clifton [1 ,2 ]
Zhang, Pengpeng [1 ]
Archambault, Yves [2 ]
Bocanek, Jim [2 ]
Tang, Grace [3 ]
LoSasso, Thomas [1 ]
机构
[1] Mem Sloan Kettering Canc Ctr, New York, NY 10021 USA
[2] Varian Med Syst, Palo Alto, CA USA
[3] Univ Maryland, Baltimore, MD 21201 USA
来源
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS | 2008年 / 72卷 / 02期
关键词
RapidArc; commissioning; QA;
D O I
10.1016/j.ijrobp.2008.05.060
中图分类号
R73 [肿瘤学];
学科分类号
100214 [肿瘤学];
摘要
Purpose: The Varian RapidArc is a system for intensity-modulated radiotherapy (IMRT) treatment planning and delivery. RapidArc incorporates capabilities such as variable dose-rate, variable gantry speed, and accurate and fast dynamic multileaf collimators (DMLC), to optimize dose conformality, delivery efficiency, accuracy and reliability. We developed RapidArc system commissioning and quality assurance (QA) procedures. Methods and Materials: Tests have been designed that evaluate RapidArc performance in a stepwise manner. First, the accuracy position during gantry rotation is examined. Second, the ability to vary and control the dose-rate and gantry speed is evaluated. Third, the combined use of variable DMLC speed and dose-rate is studied. Results: Adapting the picket fence test for RapidArc, we compared the patterns obtained with stationary gantry and in RapidArc mode, and showed that the effect of gantry rotation on leaf accuracy was minimal (<= 0.2 mm). We then combine different dose-rates (111-600 MU/min), gantry speeds (5.5-4.3 degrees/s), and gantry range (Delta theta = 90-12.9 degrees) to give the same dose to seven parts of a film. When normalized to a corresponding open field (to account for flatness and asymmetry), the dose of the seven portions show good agreement, with a mean deviation of 0.7%. In assessing DMLC speed (0.46, 0.92, 1.84, and 2.76 cm/s) during RapidArc, the analysis of designed radiation pattern indicates good agreement, with a mean deviation of 0.4%. Conclusions: The results of these tests provide strong evidence that DMLC movement, variable dose-rates and gantry speeds can be precisely controlled during RapidArc. (C) 2008 Elsevier Inc.
引用
收藏
页码:575 / 581
页数:7
相关论文
共 22 条
[1]
Comparison of plan quality provided by intensity-modulated arc therapy and helical tomotherapy [J].
Cao, Daliang ;
Holmes, Timothy W. ;
Afghan, Muhammad K. N. ;
Shepard, David M. .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2007, 69 (01) :240-250
[2]
Initial clinical experience with the Peacock intensity modulation of a 3-D conformal radiation therapy system [J].
Carol, M ;
Grant, WH ;
Pavord, D ;
Eddy, P ;
Targovnik, HS ;
Butler, B ;
Woo, S ;
Figura, J ;
Onufrey, V ;
Grossman, R ;
Selkar, R .
STEREOTACTIC AND FUNCTIONAL NEUROSURGERY, 1996, 66 (1-3) :30-34
[3]
Testing of dynamic multileaf collimation [J].
Chui, CS ;
Spirou, S ;
LoSasso, T .
MEDICAL PHYSICS, 1996, 23 (05) :635-641
[4]
Leaf position optimization for step-and-shoot IMRT [J].
De Gersem, W ;
Claus, F ;
De Wagter, C ;
Van Duyse, B ;
De Neve, W .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2001, 51 (05) :1371-1388
[5]
Inverse planning for intensity-modulated arc therapy using direct aperture optimization [J].
Earl, MA ;
Shepard, DM ;
Naqvi, S ;
Li, XA ;
Yu, CX .
PHYSICS IN MEDICINE AND BIOLOGY, 2003, 48 (08) :1075-1089
[6]
Commissioning of a commercially available system for intensity-modulated radiotherapy dose delivery with dynamic multileaf collimation [J].
Essers, M ;
de Langen, M ;
Dirkx, MLP ;
Heijmen, BJM .
RADIOTHERAPY AND ONCOLOGY, 2001, 60 (02) :215-224
[7]
IMAT-SIM: A new method for the clinical dosimetry of intensity-modulated arc therapy (IMAT) [J].
Iori, Mauro ;
Cagni, Elisabetta ;
Nahum, Alan E. ;
Borasi, Giovanni .
MEDICAL PHYSICS, 2007, 34 (07) :2759-2773
[8]
Conformal radiation treatment of prostate cancer using inversely-planned intensity-modulated photon beams produced with dynamic multileaf collimation [J].
Ling, CC ;
Burman, C ;
Chui, CS ;
Kutcher, GJ ;
Leibel, SA ;
LoSasso, T ;
Mohan, R ;
Bortfeld, T ;
Reinstein, L ;
Spirou, S ;
Wang, XH ;
Wu, QW ;
Zelefsky, M ;
Fuks, Z .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 1996, 35 (04) :721-730
[9]
LING CC, 2003, PRACTICAL GUIDE INTE, P123
[10]
Comprehensive quality assurance for the delivery of intensity modulated radiotherapy with a multileaf collimator used in the dynamic mode [J].
LoSasso, T ;
Chui, CS ;
Ling, CC .
MEDICAL PHYSICS, 2001, 28 (11) :2209-2219