A new interface for combining capillary electrophoresis with inductively coupled plasma-mass spectrometry

被引:111
作者
Schaumlöffel, D [1 ]
Prange, A [1 ]
机构
[1] GKSS Forschungszentrum Geesthacht GmbH, Inst Phys & Chem Analyt, D-21502 Geesthacht, Germany
来源
FRESENIUS JOURNAL OF ANALYTICAL CHEMISTRY | 1999年 / 364卷 / 05期
关键词
D O I
10.1007/s002160051366
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
This paper describes the development and design of a new, efficient, simple and robust interface for coupling capillary electrophoresis (CE) with inductively coupled plasma-mass spectrometry. The interface is based on a modified microconcentric nebulizer which permits a low flow rate of about 6 mu L/min in the free aspiration mode. This interface construction provides an electrical connection for stable electrophoretic separations and adapts the flow rate of the electro-osmotic flow inside the CE capillary to the flow rate of the nebulizer for efficient transport of the analytes into the plasma. By optimization of the fluid mechanical proper-ties the interface prevents the nebulizer from causing any laminar flow in the CE capillary and thus the high resolution power of CE can be preserved. Furthermore, this new device permits independent optimization of the nebulization from the CE whereby exact positioning of the CE capillary is not necessary, thus enabling fast exchange. A low dead volume spraychamber has been constructed which circumvents any band broadening of the sharp CE signals. Peak widths down to 3.5 s comparable to CE with UV detection are possible.
引用
收藏
页码:452 / 456
页数:5
相关论文
共 11 条
[1]   Capillary electrophoresis and inductively coupled plasma spectrometry: Status report [J].
Barnes, RM .
FRESENIUS JOURNAL OF ANALYTICAL CHEMISTRY, 1998, 361 (03) :246-251
[2]   Effect of laminar flow in capillary electrophoresis: Model and experimental results on controlling analysis time and resolution with inductively coupled plasma mass spectrometry detection [J].
Kinzer, JA ;
Olesik, JW ;
Olesik, SV .
ANALYTICAL CHEMISTRY, 1996, 68 (18) :3250-3257
[3]   An evaluation of ultrasonic nebulizers as interfaces for capillary electrophoresis of inorganic anions and cations with inductively coupled plasma mass spectrometric detection [J].
Kirlew, PW ;
Castillano, MTM ;
Caruso, JA .
SPECTROCHIMICA ACTA PART B-ATOMIC SPECTROSCOPY, 1998, 53 (02) :221-237
[4]  
LIU Y, 1998, ANAL CHEM, V13, P1095
[5]   Evaluation of an ultrasonic nebulizer interface for capillary electrophoresis and inductively coupled plasma mass spectrometry [J].
Lu, QH ;
Barnes, RM .
MICROCHEMICAL JOURNAL, 1996, 54 (02) :129-143
[6]   INTERFACE FOR CAPILLARY ELECTROPHORESIS AND INDUCTIVELY-COUPLED PLASMA-MASS SPECTROMETRY [J].
LU, QH ;
BIRD, SM ;
BARNES, RM .
ANALYTICAL CHEMISTRY, 1995, 67 (17) :2949-2956
[7]   Two simple interface designs for capillary electrophoresis inductively coupled plasma mass spectrometry [J].
Majidi, V ;
Miller-Ihli, NJ .
ANALYST, 1998, 123 (05) :803-808
[8]   Interface for coupling capillary electrophoresis to inductively coupled plasma and on-column concentration technique [J].
Mei, E ;
Ichihashi, H ;
Gu, WF ;
Yamasaki, SI .
ANALYTICAL CHEMISTRY, 1997, 69 (11) :2187-2192
[9]  
OLESIK JW, 1995, ANAL CHEM, V65, P1
[10]  
SCHAUMLOFFEL D, 1998, Patent No. 19841288