Piezoelectric biosensors for real-time monitoring of hybridization and detection of hepatitis C virus

被引:58
作者
Skládal, P
Riccardi, CD
Yamanaka, H
da Costa, PI
机构
[1] Univ Estadual Paulista, Inst Chem, Dept Analyt Chem, BR-14801900 Araraquara, SP, Brazil
[2] Masaryk Univ, Fac Sci, Dept Biochem, CS-61137 Brno, Czech Republic
[3] Univ Estadual Paulista, Fac Pharmaceut Sci, BR-14801902 Araraquara, SP, Brazil
基金
巴西圣保罗研究基金会;
关键词
piezoelectric biosensor; hepatitis C virus; RT-PCR;
D O I
10.1016/j.jviromet.2004.01.005
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
The piezoelectric quartz crystal resonators modified with oligonucleotide probes were used for detection of hepatitis C virus (HCV) in serum. The gold electrodes on either rough or smooth surface crystals were modified with a self-assembled monolayer of cystamine. After activation with glutaraldehyde, either avidin or streptavidin were immobilized and used for attachment of biotinylated DNA probes (four different sequences). Piezoelectric biosensors were used in a flow-through setup for direct monitoring of DNA resulting from the reverse transcriptase-linked polymerase chain reaction (RT-PCR) amplification of the original viral RNA. The samples of patients with hepatitis C were analyzed and the results were compared with the standard RT-PCR procedure (Amplicor test kit of Roche, microwell format with spectrophotometric evaluation). The piezoelectric hybridization assay was completed in 10 min and the same sensing surface was suitable for repeated use. (C) 2004 Elsevier B.V. All rights reserved.
引用
收藏
页码:145 / 151
页数:7
相关论文
共 27 条
[1]   Low levels of hepatitis C virus RNA in serum, plasma, and peripheral blood mononuclear cells of injecting drug users during long antibody-undetectable periods before seroconversion [J].
Beld, M ;
Penning, M ;
van Putten, M ;
van den Hoek, A ;
Damen, M ;
Klein, MR ;
Goudsmit, J .
BLOOD, 1999, 94 (04) :1183-1191
[2]  
Cavic BA, 1997, FARADAY DISCUSS, V107, P159
[3]   DETECTION OF HEPATITIS-C VIRUS-INFECTION WITH RECOMBINANT IMMUNOBLOT ASSAY, SYNTHETIC IMMUNOBLOT ASSAY, AND POLYMERASE CHAIN-REACTION [J].
CHAUDHARY, RK ;
ANDONOV, A ;
MACLEAN, C .
JOURNAL OF CLINICAL LABORATORY ANALYSIS, 1993, 7 (03) :164-167
[4]  
Chen ZZ, 2003, ACTA CHIM SINICA, V61, P137
[5]  
Chen ZZ, 2002, CHEM J CHINESE U, V23, P1044
[6]   HEPATITIS-C VIRUS - THE MAJOR CAUSATIVE AGENT OF VIRAL NON-A, NON-B HEPATITIS [J].
CHOO, QL ;
WEINER, AJ ;
OVERBY, LR ;
KUO, G ;
HOUGHTON, M ;
BRADLEY, DW .
BRITISH MEDICAL BULLETIN, 1990, 46 (02) :423-441
[7]   Detection of two orchid viruses using quartz crystal microbalance-based DNA biosensors [J].
Eun, AJC ;
Huang, LQ ;
Chew, FT ;
Li, SFY ;
Wong, SM .
PHYTOPATHOLOGY, 2002, 92 (06) :654-658
[8]  
Furtado LM, 1998, ANALYST, V123, P1937
[9]   Investigation of highly sensitive piezoelectric immunosensors for 2,4-dichlorophenoxyacetic acid [J].
Halámek, J ;
Hepel, M ;
Skládal, P .
BIOSENSORS & BIOELECTRONICS, 2001, 16 (4-5) :253-260
[10]   A novel RT-PCR for reliable and rapid HCV RNA screening of blood donations [J].
Hennig, H ;
Luhm, J ;
Hartwig, D ;
Klüter, H ;
Kirchner, H .
TRANSFUSION, 2001, 41 (09) :1100-1106