Piezoelectric biosensors for real-time monitoring of hybridization and detection of hepatitis C virus

被引:58
作者
Skládal, P
Riccardi, CD
Yamanaka, H
da Costa, PI
机构
[1] Univ Estadual Paulista, Inst Chem, Dept Analyt Chem, BR-14801900 Araraquara, SP, Brazil
[2] Masaryk Univ, Fac Sci, Dept Biochem, CS-61137 Brno, Czech Republic
[3] Univ Estadual Paulista, Fac Pharmaceut Sci, BR-14801902 Araraquara, SP, Brazil
基金
巴西圣保罗研究基金会;
关键词
piezoelectric biosensor; hepatitis C virus; RT-PCR;
D O I
10.1016/j.jviromet.2004.01.005
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
The piezoelectric quartz crystal resonators modified with oligonucleotide probes were used for detection of hepatitis C virus (HCV) in serum. The gold electrodes on either rough or smooth surface crystals were modified with a self-assembled monolayer of cystamine. After activation with glutaraldehyde, either avidin or streptavidin were immobilized and used for attachment of biotinylated DNA probes (four different sequences). Piezoelectric biosensors were used in a flow-through setup for direct monitoring of DNA resulting from the reverse transcriptase-linked polymerase chain reaction (RT-PCR) amplification of the original viral RNA. The samples of patients with hepatitis C were analyzed and the results were compared with the standard RT-PCR procedure (Amplicor test kit of Roche, microwell format with spectrophotometric evaluation). The piezoelectric hybridization assay was completed in 10 min and the same sensing surface was suitable for repeated use. (C) 2004 Elsevier B.V. All rights reserved.
引用
收藏
页码:145 / 151
页数:7
相关论文
共 27 条
[11]   The application of the bioelectric recognition assay for the detection of human and plant viruses: definition of operational parameters [J].
Kintzios, S ;
Pistola, E ;
Konstas, J ;
Bem, F ;
Matakiadis, T ;
Alexandropoulos, N ;
Biselis, I ;
Levin, R .
BIOSENSORS & BIOELECTRONICS, 2001, 16 (7-8) :467-480
[12]   A PIEZOELECTRIC IMMUNOSENSOR FOR HEPATITIS VIRUSES [J].
KONIG, B ;
GRATZEL, M .
ANALYTICA CHIMICA ACTA, 1995, 309 (1-3) :19-25
[13]   Development of a cell-based assay for monitoring specific hepatitis C virus NS3/4A protease activity in mammalian cells [J].
Lee, JC ;
Shih, YF ;
Hsu, SP ;
Chang, TY ;
Chen, LH ;
Hsu, JTA .
ANALYTICAL BIOCHEMISTRY, 2003, 316 (02) :162-170
[14]   Quartz crystal microbalance (QCM) affinity biosensor for genetically modified organisms (GMOs) detection [J].
Mannelli, I ;
Minunni, M ;
Tombelli, S ;
Mascini, M .
BIOSENSORS & BIOELECTRONICS, 2003, 18 (2-3) :129-140
[15]   Detection of β-thalassemia by a DNA piezoelectric biosensor coupled with polymerase chain reaction [J].
Minunni, M ;
Tombelli, S ;
Scielzi, R ;
Mannelli, I ;
Mascini, M ;
Gaudiano, C .
ANALYTICA CHIMICA ACTA, 2003, 481 (01) :55-64
[16]  
MITSUI T, 1992, HEPATOLOGY, V16, P1109, DOI 10.1002/hep.1840160502
[17]  
O'Meara D, 1998, J CLIN MICROBIOL, V36, P2454
[18]   Capture of single-stranded DNA assisted by oligonucleotide modules [J].
O'Meara, D ;
Nilsson, P ;
Nygren, PÅ ;
Uhlén, M ;
Lundeberg, J .
ANALYTICAL BIOCHEMISTRY, 1998, 255 (02) :195-203
[19]   Uses of biosensor technology in the development of probes for viral diagnosis [J].
RichaletSecordel, PM ;
Poisson, F ;
VanRegenmortel, MHV .
CLINICAL AND DIAGNOSTIC VIROLOGY, 1996, 5 (2-3) :111-119
[20]   VERWENDUNG VON SCHWINGQUARZEN ZUR WAGUNG DUNNER SCHICHTEN UND ZUR MIKROWAGUNG [J].
SAUERBREY, G .
ZEITSCHRIFT FUR PHYSIK, 1959, 155 (02) :206-222