Piezoelectric biosensors for real-time monitoring of hybridization and detection of hepatitis C virus

被引:58
作者
Skládal, P
Riccardi, CD
Yamanaka, H
da Costa, PI
机构
[1] Univ Estadual Paulista, Inst Chem, Dept Analyt Chem, BR-14801900 Araraquara, SP, Brazil
[2] Masaryk Univ, Fac Sci, Dept Biochem, CS-61137 Brno, Czech Republic
[3] Univ Estadual Paulista, Fac Pharmaceut Sci, BR-14801902 Araraquara, SP, Brazil
基金
巴西圣保罗研究基金会;
关键词
piezoelectric biosensor; hepatitis C virus; RT-PCR;
D O I
10.1016/j.jviromet.2004.01.005
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
The piezoelectric quartz crystal resonators modified with oligonucleotide probes were used for detection of hepatitis C virus (HCV) in serum. The gold electrodes on either rough or smooth surface crystals were modified with a self-assembled monolayer of cystamine. After activation with glutaraldehyde, either avidin or streptavidin were immobilized and used for attachment of biotinylated DNA probes (four different sequences). Piezoelectric biosensors were used in a flow-through setup for direct monitoring of DNA resulting from the reverse transcriptase-linked polymerase chain reaction (RT-PCR) amplification of the original viral RNA. The samples of patients with hepatitis C were analyzed and the results were compared with the standard RT-PCR procedure (Amplicor test kit of Roche, microwell format with spectrophotometric evaluation). The piezoelectric hybridization assay was completed in 10 min and the same sensing surface was suitable for repeated use. (C) 2004 Elsevier B.V. All rights reserved.
引用
收藏
页码:145 / 151
页数:7
相关论文
共 27 条
[21]   Kinetic studies of affinity interactions:: Comparison of piezoelectric and resonant mirror-based biosensors [J].
Skládal, P ;
Horácek, J .
ANALYTICAL LETTERS, 1999, 32 (08) :1519-1529
[22]   PLATINUM ANTICANCER DRUG-BINDING TO DNA DETECTED BY THICKNESS-SHEAR-MODE ACOUSTIC-WAVE SENSOR [J].
SU, HB ;
WILLIAMS, P ;
THOMPSON, M .
ANALYTICAL CHEMISTRY, 1995, 67 (05) :1010-1013
[23]   RECENT DEVELOPMENTS IN PIEZOELECTRIC IMMUNOSENSORS [J].
SULEIMAN, AA ;
GUILBAULT, GG .
ANALYST, 1994, 119 (11) :2279-2282
[24]   A DNA piezoelectric biosensor assay coupled with a polymerase chain reaction for bacterial toxicity determination in environmental samples [J].
Tombelli, S ;
Mascini, M ;
Sacco, C ;
Turner, APF .
ANALYTICA CHIMICA ACTA, 2000, 418 (01) :1-9
[25]   DETECTION OF HEPATITIS-C VIRUS-RNA BY A COMBINED REVERSE TRANSCRIPTION POLYMERASE CHAIN-REACTION ASSAY [J].
YOUNG, KKY ;
RESNICK, RM ;
MYERS, TW .
JOURNAL OF CLINICAL MICROBIOLOGY, 1993, 31 (04) :882-886
[26]   Human recombinant single-chain antibody fragments, specific for the hypervariable region 1 of hepatitis C virus, from immune phage-display libraries [J].
Zhai, W ;
Davies, J ;
Shang, DZ ;
Chan, SW ;
Allain, JP .
JOURNAL OF VIRAL HEPATITIS, 1999, 6 (02) :115-124
[27]   Detection of hepatitis B virus by piezoelectric biosensor [J].
Zhou, XD ;
Liu, LJ ;
Hu, M ;
Wang, LL ;
Hu, JM .
JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 2002, 27 (1-2) :341-345