Comparison of central corneal thickness measurements by rotating Scheimpflug camera, ultrasonic pachymetry, and scanning-slit corneal topography

被引:143
作者
Amano, S
Honda, N
Amano, Y
Yamagami, S
Miyai, T
Samejima, T
Ogata, M
Miyata, K
机构
[1] Univ Tokyo, Sch Med, Dept Ophthalmol, Tokyo 113, Japan
[2] Miyata Eye Hosp, Meiwakai Med Fdn, Miyazaki, Japan
关键词
D O I
10.1016/j.ophtha.2006.01.063
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Purpose: To compare central corneal thickness measurements and their reproducibility when taken by a rotating Scheimpflug camera, ultrasonic pachymetry, and scanning-slit corneal topography/pachymetry. Design: Experimental study. Participants: Seventy-four eyes of 64 subjects without ocular abnormalities other than cataract. Methods: Corneal thickness measurements were compared among the 3 methods in 54 eyes of 54 subjects. Two sets of measurements were repeated by a single examiner for each pachymetry in another 10 eyes of 5 subjects, and the intraexaminer repeatability was assessed as the absolute difference of the first and second measurements. Two experienced examiners took one measurement for each pachymetry in another 10 eyes of 5 subjects, and the interexaminer reproducibility was assessed as the absolute difference of the 2 measurements of the first and second examiners. Main Outcome Measures: Central corneal thickness measurements by the 3 methods, absolute difference of the first and second measurements by a single examiner, absolute difference of the 2 measurements by 2 examiners, and relative amount of variation. Results: The average measurements of central corneal thickness by a rotating Scheimpflug camera, scanning-slit topography, and ultrasonic pachymetry were 538 +/- 31.3 mu m, 541 +/- 40.7 mu m, and 545 +/- 31.3 mu m, respectively. There were no statistically significant differences in the measurement results among the 3 methods (P = 0.569, repeated-measures analysis of variance). There was a significant linear correlation between the rotating Scheimpflug camera and ultrasonic pachymetry (r = 0.908, P < 0.0001), rotating Scheimpflug camera and scanning-slit topography (r = 0.930, P < 0.0001), and ultrasonic pachymetry and scanning-slit topography (r = 0.887, P < 0.0001). Ultrasonic pachymetry had the smallest intraexaminer variability, and scanning-slit topography had the largest intraexaminer variability among the 3 methods. There were similar variations in interexaminer reproducibility among the 3 methods. Conclusions: Mean corneal thicknesses were comparable among rotating Scheimpflug camera, ultrasonic pachymetry, and scanning-slit topography with the acoustic equivalent correction factor. The measurements of the 3 instruments had significant linear correlations with one another, and all methods had highly satisfactory measurement repeatability.
引用
收藏
页码:937 / 941
页数:5
相关论文
共 14 条
[1]   STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT [J].
BLAND, JM ;
ALTMAN, DG .
LANCET, 1986, 1 (8476) :307-310
[2]  
Bovelle R, 1999, ARCH OPHTHALMOL-CHIC, V117, P868
[3]   Comparison of corneal thickness measurements using ultrasound and Orbscan slit-scanning topography in normal and post-LASIK eyes [J].
Chakrabarti, HS ;
Craig, JP ;
Brahma, A ;
Malik, TY ;
McGhee, CNJ .
JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2001, 27 (11) :1823-1828
[4]   Comparison of corneal pachymetry using ultrasound and Orbscan II [J].
Fakhry, MA ;
Artola, A ;
Belda, JL ;
Ayala, MJ ;
Alió, JL .
JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2002, 28 (02) :248-252
[5]   Corneal pachymetry in normal and keratoconic eyes: Orbscan II versus ultrasound [J].
Gherghel, D ;
Hosking, SL ;
Mantry, S ;
Banerjee, S ;
Naroo, SA ;
Shah, S .
JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2004, 30 (06) :1272-1277
[6]   Accuracy of Orbscan pachymetry measurements and DHG ultrasound pachymetry in primary laser in situ keratomileusis and LASIK enhancement procedures [J].
Iskander, NG ;
Penno, EA ;
Peters, NT ;
Gimbel, HV ;
Ferensowicz, M .
JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2001, 27 (05) :681-685
[7]   Comparison of corneal thickness measurements using Orbscan II, non-contact specular microscopy, and ultrasonic pachymetry in eyes after laser in situ keratomileusis [J].
Kawana, K ;
Tokunaga, T ;
Miyata, K ;
Okamoto, F ;
Kiuchi, T ;
Oshika, T .
BRITISH JOURNAL OF OPHTHALMOLOGY, 2004, 88 (04) :466-468
[8]   The repeatability of corneal thickness measures [J].
Marsich, MM ;
Bullimore, MA .
CORNEA, 2000, 19 (06) :792-795
[9]   Intraobserver and interobserver reproducibility in the evaluation of ultrasonic pachymetry measurements of central corneal thickness [J].
Miglior, S ;
Albe, E ;
Guareschi, M ;
Mandelli, G ;
Gomarasca, S ;
Orzalesi, N .
BRITISH JOURNAL OF OPHTHALMOLOGY, 2004, 88 (02) :174-177
[10]   Scanning-slit and specular microscopic pachymetry in comparison with ultrasonic determination of corneal thickness [J].
Modis, L ;
Langenbucher, A ;
Seitz, B .
CORNEA, 2001, 20 (07) :711-714