Self blood glucose monitoring in type 2 diabetes. A financial impact analysis based on UK primary care

被引:18
作者
Belsey, J. D. [1 ]
Pittard, J. B.
Rao, S. [2 ]
Urdahl, H. [3 ]
Jameson, K. [3 ]
Dixon, T. [1 ]
机构
[1] JB Med Ltd, Sudbury CO10 0PB, Suffolk, England
[2] Soar Beyond Ltd, St Albans, Herts, England
[3] Merck Sharp & Dohme Ltd, Outcomes Res, Hoddendon, Herts, England
关键词
INTENSIVE TREATMENT; METABOLIC-CONTROL; INSULIN; HEMOGLOBIN; MANAGEMENT; MELLITUS; HYPOGLYCEMIA; ASSOCIATION; HIERARCHY; THERAPY;
D O I
10.1111/j.1742-1241.2008.01992.x
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
UK consensus guidelines recommend limited use of self-monitoring of blood glucose (SMBG) in patients with type 2 diabetes using diet and exercise, metformin and/or a glitazone. This analysis quantifies the usage of and costs associated with SMBG in type 2 diabetes according to treatment regimen. Prevalence data for diabetes were assessed using UK Quality and Outcomes Framework returns for 2006/2007. Data on current SMBG prescribing expenditure were extracted from UK Prescription Pricing Agency Data for 2007. Prescribing data were extracted from the records of 40,651 patients with diabetes on the IMS Disease Analyzer (MediPlus) database. These were combined to arrive at mean usage and expenditure data per patient, broken down by treatment type. The analysis assumes that it is appropriate to use patients' treatment regimen alone to compare the frequency of SMBG in clinical practice with the frequency recommended in treatment guidelines; it does not take into account other valid reasons for SMBG. Mean national expenditure on SMBG was 73.64 pound per patient per year. Estimated mean weekly test strip usage by treatment was 2.5 (diet), 2.6 (glitazone monotherapy), 3.1 (metformin monotherapy) and 3.5 (sulphonylurea monotherapy). Combination oral therapy ranged from 3.3 to 4.1. Mean annual expenditure in patients with an identified treatment type was 62.06 pound per patient, ranging from 9.83 pound for diet-treated patients to 37.87 pound for those on triple therapy, with insulin-treated patients incurring costs 3-5 times higher. Based on the assumptions that the treatment regimen is the sole factor in determining the appropriate level of SMBG frequency, this study demonstrates that the use of SMBG exceeds current guidelines in certain treatment groups. The study estimates that the potential savings of up to 17 pound million could be made each year if guidelines were followed more closely. There is a need for further research into SMBG use in patients with type 2 diabetes.
引用
收藏
页码:439 / 448
页数:10
相关论文
共 50 条
[31]  
O'Kane MJ, 2008, BMJ-BRIT MED J, V336, P1174, DOI 10.1136/bmj.39534.571644.BE
[32]  
Owens D., 2004, Diabetes and Primary Care, V6, P8
[33]  
OWENS D, 2005, DIABETES PRIM CARE, V7, P9
[34]   Self monitoring of blood glucose in type 2 diabetes: longitudinal qualitative study of patients' perspectives [J].
Peel, Elizabeth ;
Douglas, Margaret ;
Lawton, Julia .
BMJ-BRITISH MEDICAL JOURNAL, 2007, 335 (7618) :493-496A
[35]  
REYNOLDS RM, 2004, BMJ-BRIT MED J, V329, P755
[36]  
*ROYAL COLL PHYSL, 2004, TYP 1 DIAB ADULTS NA
[37]   FEASIBILITY AND EFFECTS OF A DIABETES TYPE-II PROTOCOL WITH BLOOD-GLUCOSE SELF-MONITORING IN GENERAL-PRACTICE [J].
RUTTEN, G ;
VANEIJK, J ;
DENOBEL, E ;
BEEK, M ;
VANDERVELDEN, H .
FAMILY PRACTICE, 1990, 7 (04) :273-278
[38]   Self-monitoring of blood glucose as part of a multi-component therapy among non-insulin requiring type 2 diabetes patients: a meta-analysis (1966-2004) [J].
Sarol, JN ;
Nicodemus, NA ;
Tan, KM ;
Grava, MB .
CURRENT MEDICAL RESEARCH AND OPINION, 2005, 21 (02) :173-183
[39]   Assessing glycemia in diabetes using self-monitoring blood glucose and hemoglobin A1c [J].
Saudek, CD ;
Derr, RL ;
Kalyani, RR .
JAMA-JOURNAL OF THE AMERICAN MEDICAL ASSOCIATION, 2006, 295 (14) :1688-1697
[40]   Meal-related structured self-monitoring of blood glucose - Effect on diabetes control in non-insulin-treated type 2 diabetic patients [J].
Schwedes, U ;
Siebolds, M ;
Mertes, G .
DIABETES CARE, 2002, 25 (11) :1928-1932