Accuracy of proximal caries depth measurements:: Comparison between limited cone beam computed tomography, storage phosphor and film radiography

被引:52
作者
Akdeniz, B. Guniz [1 ]
Grondahl, Hans-Goran
Magnusson, Bengt
机构
[1] Ege Univ, Sch Dent, Dishekimligi Fak Oral Diagnoz & Rad AD, Dept Oral Diag & Radiol, TR-35100 Izmir, Turkey
[2] Univ Gothenburg, Sahlgrenska Acad, Fac Odontol, Dept Oral & Maxillofacial Radiol, Gothenburg, Sweden
[3] Univ Gothenburg, Sahlgrenska Acad, Dept Oral Pathol, Gothenburg, Sweden
关键词
cone beam X-ray CT; digital radiography;
D O I
10.1159/000092226
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
The aim of this study was to compare the accuracy of limited cone beam computed tomography (LCBCT), an image plate system and F-speed film in assessing the depth of proximal carious lesions. Radiographs of a dry mandible with sound and carious teeth were obtained with all three methods. In 41 molar and premolar proximal surfaces, 2 observers independently measured lesion depth on the images from the three modalities. The correlation of measurements was assessed with Pearson's correlation analysis. Results from imaging modalities and histological sectioning (gold standard) were compared using Bland-Altman plots. Overall comparison of the depth measurements from the imaging modalities and the gold standard was done using repeated-measures ANOVA. Pairwise comparisons of systems were done by the Bonferroni t test. The correlation between the measurements of the two observers was 0.977 for film, 0.997 for image plate system and 0.998 for LCBCT. Bland-Altman plots revealed that LCBCT agreed very closely with the gold standard while the agreement between the latter and the image plate - or film - images was moderate. The mean difference and 95% limits of agreement between LCBCT and the gold standard were smaller than those between either image plate or F-speed film and the gold standard. The LCBCT method appears as a promising tool for detection and monitoring of proximal carious lesions.
引用
收藏
页码:202 / 207
页数:6
相关论文
共 18 条
[1]   Influence of the number of basis images and projection array on caries detection using tuned aperture computed tomography (TACT) [J].
Abreu, M ;
Tyndall, DA ;
Ludlow, JB ;
Nortjé, CJ .
DENTOMAXILLOFACIAL RADIOLOGY, 2002, 31 (01) :24-31
[2]   Effect of angular disparity of basis images and projection geometry on caries detection using tuned-aperture computed tomography [J].
Abreu, M ;
Tyndall, DA ;
Ludlow, JB .
ORAL SURGERY ORAL MEDICINE ORAL PATHOLOGY ORAL RADIOLOGY AND ENDODONTICS, 2001, 92 (03) :353-360
[3]   Development of a compact computed tomographic apparatus for dental use [J].
Arai, Y ;
Tammisalo, E ;
Iwai, K ;
Hashimoto, K ;
Shinoda, K .
DENTOMAXILLOFACIAL RADIOLOGY, 1999, 28 (04) :245-248
[4]  
Arai Y., 2000, DENT RADIOL, V40, P145
[5]   STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT [J].
BLAND, JM ;
ALTMAN, DG .
LANCET, 1986, 1 (8476) :307-310
[6]   The effect of alterations in horizontal X-ray beam angulation and bucco-lingual cavity width on the radiographic depth of approximal cavities [J].
Chadwick, BL ;
Dummer, PMH ;
Van der Stelt, PF .
JOURNAL OF ORAL REHABILITATION, 1999, 26 (04) :292-301
[7]  
Danforth Robert A, 2003, J Calif Dent Assoc, V31, P817
[8]   CLINICAL AND RADIOGRAPHIC ASSESSMENT OF APPROXIMAL CARIOUS LESIONS [J].
ESPELID, I ;
TVEIT, AB .
ACTA ODONTOLOGICA SCANDINAVICA, 1986, 44 (01) :31-37
[9]   THE USE OF A COMPUTER-BASED IMAGE-ANALYSIS PROGRAM FOR THE DIAGNOSIS OF APPROXIMAL CARIES FROM BITEWING RADIOGRAPHS [J].
HEAVEN, TJ ;
WEEMS, RA ;
FIRESTONE, AR .
CARIES RESEARCH, 1994, 28 (01) :55-58
[10]  
IWAI K, 2000, DENT RADIOL, V40, P251