Factors influencing timing resolution in a commercial LSO PET camera

被引:51
作者
Moses, WW [1 ]
Ullisch, M
机构
[1] Lawrence Berkeley Natl Lab, Berkeley, CA 94720 USA
[2] Univ Hamburg, Hamburg, Germany
基金
美国国家卫生研究院;
关键词
LSO; PET; time-of-flight; timing resolution;
D O I
10.1109/TNS.2005.862980
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
The CPS Accel is a commercial PET camera based on a block detector with 64 LSO scintillator crystals (each 6.75 x 6.75 x 25 mm) read out with 4 photomultiplier tubes. The excellent timing resolution of LSO suggests that this camera might be used for time-of-flight (TOF) PET, thereby reducing the statistical noise significantly. Although the Accel achieves 3 ns coincidence resolution (a factor of two better than BGO-based PET cameras), its timing resolution is nearly an order of magnitude worse than that demonstrated with individual LSO crystals. This paper quantifies the effect on the timing of each component in the Accel timing chain to identify which components most limit the camera's timing resolution. The components in the timing chain are: the scintillator crystal, the photomultiplier tube (PMT), the constant fraction discriminator (CFD), and the time to digital converter (TDC). To measure the contribution of each component, we construct a single crystal test system with high-performance versions of these components. This system achieves 221 ps FWHM coincidence timing resolution, which is used as a baseline measurement. One of the high-performance components is replaced by a production component, the coincidence timing resolution is re-measured, and the difference between measurements is the contribution of that (production) component. We find that the contributions of the TDC, CFD, PMT, and scintillator are 2000 ps, 1354 ps, 422 ps, and 326 ps FWHM, respectively, and that the overall timing resolution scales like the square root of the amount of scintillation light detected by the PMT. Based on these measurements we predict that the limit for the coincidence timing resolution in a practical, commercial, LSO-based PET camera is 528 ps FWHM.
引用
收藏
页码:78 / 85
页数:8
相关论文
共 40 条
[31]  
SURTI S, 2004, P IEEE NUCL SCI S RO, pM10
[32]  
SURTI S, 2003, P IEEE NUCL SCI S ME, pM3
[33]   A custom mixed-signal CMOS integrated circuit for high performance PET tomograph front-end applications [J].
Swann, BK ;
Rochelle, JM ;
Binkley, DM ;
Puckett, BS ;
Blalock, BJ ;
Terry, SC ;
Moyers, JC ;
Young, JW ;
Casey, ME ;
Musrock, MS ;
Breeding, JE .
IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2003, 50 (04) :909-914
[34]  
Ter-Pogossian M M, 1982, IEEE Trans Med Imaging, V1, P179, DOI 10.1109/TMI.1982.4307570
[35]   THE SUPER PET 3000-E - A PET SCANNER DESIGNED FOR HIGH COUNT RATE CARDIAC APPLICATIONS [J].
TERPOGOSSIAN, MM ;
FICKE, DC ;
BEECHER, DE ;
HOFFMANN, GR ;
BERGMANN, SR .
JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 1994, 18 (04) :661-669
[36]  
TERPOGOSSIAN MM, 1982, P WORKSH TIM FLIGHT, P37
[37]   A method for determination of the timing stability of PET scanners [J].
Thompson, CJ ;
Goertzen, AL .
IEEE TRANSACTIONS ON MEDICAL IMAGING, 2005, 24 (08) :1053-1057
[38]   The ECAT HRRT: Performance and first clinical application of the new high resolution research tomograph [J].
Wienhard, K ;
Schmand, M ;
Casey, ME ;
Baker, K ;
Bao, J ;
Eriksson, L ;
Jones, WF ;
Knoess, C ;
Lenox, M ;
Lercher, M ;
Luk, P ;
Michel, C ;
Reed, JH ;
Richerzhagen, N ;
Treffert, J ;
Vollmar, S ;
Young, JW ;
Heiss, WD ;
Nutt, R .
IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2002, 49 (01) :104-110
[39]  
WONG WH, 1983, J NUCL MED, V24, P52
[40]   FPGA based front-end electronics for a high resolution PET scanner [J].
Young, JW ;
Moyers, JC ;
Lenox, M .
IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2000, 47 (04) :1676-1680