Elimination of electrocardiogram contamination from electromyogram signals: An evaluation of currently used removal techniques

被引:289
作者
Drake, JDM [1 ]
Callaghan, JP [1 ]
机构
[1] Univ Waterloo, Fac Appl Hlth Sci, Dept Kinesiol, Waterloo, ON N2L 3G1, Canada
基金
加拿大自然科学与工程研究理事会; 加拿大健康研究院; 加拿大创新基金会;
关键词
ECG contamination; EMG; high pass filter; subtraction template; gating;
D O I
10.1016/j.jelekin.2005.07.003
中图分类号
Q189 [神经科学];
学科分类号
071006 ;
摘要
Trunk electromyographic signals (EMG) are often contaminated with heart muscle electrical activity (ECG) due to the proximity of the collection sites to the heart and the volume conduction characteristics of the ECG through the torso. Few studies have quantified ECG removal techniques relative to all uncontaminated EMG signal (gold standard or criterion measure), or made direct comparisons between different methods for it given set of data. Understanding the impacts of both untreated contaminated EMG and ECG elimination techniques oil the amplitude and frequency parameters is vital given the widespread use of EMG. The purpose of this study was to evaluate four groups of current and commonly used techniques for the removal of ECG contamination from EMG signals. ECG recordings at two intensity levels (rest and 50% maximum predicted heart rate) were superimposed on I I uncontaminated biceps brachii EMG signals (rest, 7 isometric and 3 isoinertial levels). The 23 removal methods used were high pass digital filtering (finite impulse response (FIR) using a Hamming window, and fourth-order Butterworth (BW) filter) at five cutoff frequencies (20, 30, 40, 50, and 60 Hz), template techniques (template Subtraction and an amplitude gating template). combinations of the subtraction template and high pass digital filtering, and a frequency subtraction/signal reconstruction method. For muscle activation levels between 10% and 25% of maximum voluntary contraction. the template subtraction and BW filter with a 30 Hz cutoff were the two best methods for maximal ECG removal with minimal EMG distortion. The BW filter with a 30 Hz cutoff provided the optimal balance between ease of implementation, time investment, and performance across all contractions and heart rate levels for the EMG levels evaluated in this study. (C) 2005 Elsevier Ltd. All rights reserved.
引用
收藏
页码:175 / 187
页数:13
相关论文
共 34 条
[1]   ADAPTIVE CANCELLATION TECHNIQUE IN PROCESSING MYOELECTRIC ACTIVITY OF RESPIRATORY MUSCLES [J].
AKKIRAJU, P ;
REDDY, DC .
IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 1992, 39 (06) :652-655
[2]   FILTERING BY ADAPTIVE SAMPLING (FAS) [J].
AMINIAN, K ;
RUFFIEUX, C ;
ROBERT, P .
MEDICAL & BIOLOGICAL ENGINEERING & COMPUTING, 1988, 26 (06) :658-662
[3]  
Araujo R C, 2000, Electromyogr Clin Neurophysiol, V40, P225
[4]   Methods to reduce the variability of EMG power spectrum estimates [J].
Baratta, RV ;
Solomonow, M ;
Zhou, BH ;
Zhu, M .
JOURNAL OF ELECTROMYOGRAPHY AND KINESIOLOGY, 1998, 8 (05) :279-285
[5]   Description and validation of a technique for the removal of ECG contamination from diaphragmatic EMG signal [J].
Bartolo, A ;
Dzwonczyk, RR ;
Roberts, C ;
Goldman, E .
MEDICAL & BIOLOGICAL ENGINEERING & COMPUTING, 1996, 34 (01) :76-81
[6]   Analysis of diaphragm EMG signals: Comparison of gating vs subtraction for removal of ECG contamination [J].
Bartolo, A ;
Roberts, C ;
Dzwonczyk, RR ;
Goldman, E .
JOURNAL OF APPLIED PHYSIOLOGY, 1996, 80 (06) :1898-1902
[7]   A comparison of ECG cancellation techniques applied to the surface recording of somatosensory evoked potentials [J].
Black, JS ;
Lovely, DF .
MEDICAL ENGINEERING & PHYSICS, 1997, 19 (03) :279-285
[8]   SUBTRACTION OF ELECTROCARDIOGRAPHIC SIGNAL FROM RESPIRATORY ELECTROMYOGRAM [J].
BLOCH, R .
JOURNAL OF APPLIED PHYSIOLOGY, 1983, 55 (02) :619-623
[9]   Examination of the myoelectric activity of back muscles during random vibration -: methodical approach and first results [J].
Blüthner, R ;
Seidel, H ;
Hinz, B .
CLINICAL BIOMECHANICS, 2001, 16 :S25-S30
[10]   Frequency response of spine extensors during rapid isometric contractions: effects of muscle length and tension [J].
Brereton, LC ;
McGill, SM .
JOURNAL OF ELECTROMYOGRAPHY AND KINESIOLOGY, 1998, 8 (04) :227-232