The effect of injection rate on time-resolved contrast-enhanced peripheral MRA

被引:49
作者
Carroll, TJ [1 ]
Korosec, FR [1 ]
Swan, JS [1 ]
Hany, TF [1 ]
Grist, TM [1 ]
Mistretta, CA [1 ]
机构
[1] Univ Wisconsin, Dept Phys Med, Madison, WI 53706 USA
关键词
contrast-enhanced; contrast injection; artifact; MR angiography; time-resolved;
D O I
10.1002/jmri.1200
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
In contrast-enhanced (CE) magnetic resonance (MR) angiography (MRA), lower injection rates of a fixed contrast agent dose provide longer contrast agent bolus at the expense of lower intravascular signal. This study evaluated the effect of different injection rates in imaging of the vasculature of the lower extremities with time-resolved, CE MRA. In three volunteers, injection rates of 0.5, 1.5 and 3.0 mL/second were administered in a randomized order and imaged in two separate sessions. Contrast agent bolus dynamics measured in volunteers were used in computer simulations to confirm variations in contrast agent concentration as a source of vessel ringing and blurring artifacts. To validate the effect of injection rate in pathologic vessels, 37 patients with peripheral vascular disease were imaged with a time-resolved technique using an injection rate of 0.5 mL/second or 1.5 mL/second and retrospectively divided into two groups. In volunteers, higher injection rates caused a stronger modulation of k-space and resulted in increased ringing artifacts in time-resolved CE MRA. These results were reproduced with computer simulations. In the qualitative patient study, significantly less vessel blurring was observed using a lower injection-rate, without a significant loss of vessel contrast. J. Magn. Reson. Imaging 2001;14:401-410. (C) 2001 Wiley-Liss, Inc.
引用
收藏
页码:401 / 410
页数:10
相关论文
共 22 条
[11]  
Look D. C., 1970, Review of Scientific Instruments, V41, P250, DOI 10.1063/1.1684482
[12]  
Maki J H, 1996, Top Magn Reson Imaging, V8, P322
[13]   The effects of time varying intravascular signal intensity and k-space acquisition order on three-dimensional MR angiography image quality [J].
Maki, JH ;
Prince, MR ;
Londy, FJ ;
Chenevert, TL .
JMRI-JOURNAL OF MAGNETIC RESONANCE IMAGING, 1996, 6 (04) :642-651
[14]   Stepping-table gadolinium-enhanced digital subtraction MR angiography of the aorta and lower extremity arteries: Preliminary experience [J].
Meaney, JFM ;
Ridgway, JP ;
Chakraverty, S ;
Robertson, I ;
Kessel, D ;
Radjenovic, A ;
Kouwenhoven, M ;
Kassner, A ;
Smith, MA .
RADIOLOGY, 1999, 211 (01) :59-67
[15]   DYNAMIC GADOLINIUM-ENHANCED 3-DIMENSIONAL ABDOMINAL MR ARTERIOGRAPHY [J].
PRINCE, MR ;
YUCEL, EK ;
KAUFMAN, JA ;
HARRISON, DC ;
GELLER, SC .
JMRI-JOURNAL OF MAGNETIC RESONANCE IMAGING, 1993, 3 (06) :877-881
[16]   MR angiography in the evaluation of atherosclerotic peripheral vascular disease [J].
Rofsky, NM ;
Adelman, MA .
RADIOLOGY, 2000, 214 (02) :325-338
[17]   Pelvic and lower extremity arterial imaging: Diagnostic performance of three-dimensional contrast-enhanced MR angiography [J].
Ruehm, SG ;
Hany, TF ;
Pfammatter, T ;
Schneider, E ;
Ladd, M ;
Debatin, JF .
AMERICAN JOURNAL OF ROENTGENOLOGY, 2000, 174 (04) :1127-1135
[18]   Aortoiliac and lower extremity arteries: Comparison of three-dimensional dynamic contrast-enhanced subtraction MR angiography and conventional angiography [J].
Sueyoshi, E ;
Sakamoto, I ;
Matsuoka, Y ;
Ogawa, Y ;
Hayashi, H ;
Hashmi, R ;
Hayashi, K .
RADIOLOGY, 1999, 210 (03) :683-688
[19]  
Svensson J, 1999, J MAGN RESON IMAGING, V10, P919, DOI 10.1002/(SICI)1522-2586(199912)10:6<919::AID-JMRI3>3.3.CO
[20]  
2-N