Results with eight and a half years average follow-up on two hundred and eight e-Motion FP® knee prostheses, fitted using computer navigation for knee osteoarthritis in patients with over ten degrees genu varum

被引:14
作者
Saragaglia, Dominique [1 ]
Sigwalt, Loic [1 ]
Gaillot, Julia [1 ]
Morin, Vincent [1 ]
Rubens-Duval, Brice [1 ]
Pailhe, Regis [1 ]
机构
[1] Grenoble South Teaching Hosp, Dept Orthopaed Surg & Sport Traumatol, F-38130 Echirolles, France
关键词
Knee; Osteoarthritis; Severe genu varum; Total knee arthroplasty; Computer-assisted; Navigation; ARTHROPLASTY; RELEASE; DEFORMITY; LIGAMENT; REPLACEMENTS;
D O I
10.1007/s00264-017-3618-8
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
100224 [整形外科学];
摘要
Purpose The aim of this study was to analyse the clinical and radiographic results of 208 e-Motion (R) posterior cruciate-retaining, mobile bearing prostheses (BBraun-Aesculap, Tuttlingen, Germany) fitted using computer navigation, for knee osteoarthritis with a genu varum greater than 10 degrees. Methods One hundred ninety-two patients were operated on with 208 e-Motion (R) prostheses fitted, between January 2006 and December 2011, using the OrthoPilot (R) computer navigation system. Average pre-operative IKS score was 70 +/- 27 points (6-143) with a function score of 38 +/- 20.5 (0-90) and a knee score of 32.5 +/- 13 (0-63). Average flexion was 116.5 degrees +/- 13 degrees (65-140 degrees). Average pre-operative HKA angle was 166 degrees +/- 3 degrees (154-169 degrees). Results 2Results are available for 134 patients, with a total of 150 knees operated on (38 lost to follow-up and 20 deceased). Average follow-up was 104.5 months (60-116 months). On last follow-up, the average IKS was 180 +/- 22 points (95-200) with 86.5 +/- 16 points (25-100) for the function score and 93.5 +/- 8 points (55-100) for the knee score. Knee flexion was 116 degrees +/- 10.5 degrees (80-135 degrees) and average HKA angle was 179 degrees +/- 2 degrees (175-184 degrees). The pre-operative objective was achieved in 90.5% of knees. Conclusion The e-Motion (R) mobile bearing posterior cruciate-retaining prosthesis, fitted using computer navigation, offers excellent results after an average of 8.5 years follow-up. These results are at least equivalent, even superior, to those of the posterior-stabilised prostheses usually used for this type of deformity.
引用
收藏
页码:799 / 804
页数:6
相关论文
共 30 条
[21]
Saragaglia D, 2005, ORTHOPEDICS, V28, pS1269
[22]
Saragaglia D, 2006, ORTHOPEDICS, V29, pS137
[23]
Computer assisted total knee arthroplasty : Grenoble 12 years experience [J].
Saragaglia, Dominique .
E-MEMOIRES DE L ACADEMIE NATIONALE DE CHIRURGIE, 2009, 8 (01) :53-58
[24]
Navigation-assisted less invasive total knee arthroplasty compared with conventional total knee arthroplasty - A randomized prospective trial [J].
Seon, Jong Keun ;
Song, Eun Kyoo .
JOURNAL OF ARTHROPLASTY, 2006, 21 (06) :777-782
[25]
Why are total knee arthroplasties failing today? [J].
Sharkey, PF ;
Hozack, WJ ;
Rothman, RH ;
Shastri, S ;
Jacoby, SM .
CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 2002, (404) :7-13
[26]
Comparison of Complete Distal Release of the Medial Collateral Ligament and Medial Epicondylar Osteotomy during Ligament Balancing in Varus Knee Total Knee Arthroplasty [J].
Sim, Jae Ang ;
Lee, Yong Seuk ;
Kwak, Ji Hoon ;
Yang, Sang Hoon ;
Kim, Kwang Hui ;
Lee, Beom Koo .
CLINICS IN ORTHOPEDIC SURGERY, 2013, 5 (04) :287-291
[27]
Stiehl J.B., 2004, NAVIG ROBOT TOTAL JT, V22, P226
[28]
TEENY SM, 1991, CLIN ORTHOP RELAT R, P19
[29]
Soft tissue balancing in varus total knee arthroplasty: an algorithmic approach [J].
Verdonk, Peter C. M. ;
Pernin, Jerome ;
Pinaroli, Alban ;
Selmi, Tarik Ait Si ;
Neyret, Philippe .
KNEE SURGERY SPORTS TRAUMATOLOGY ARTHROSCOPY, 2009, 17 (06) :660-666
[30]
WHITESIDE LA, 1995, ORTHOPEDICS, V18, P117, DOI 10.3928/0147-7447-19950201-09