Interfacing capillary gel microfluidic chips with infrared laser desorption mass spectrometry

被引:24
作者
Xu, YC [1 ]
Little, MW [1 ]
Murray, KK [1 ]
机构
[1] Louisiana State Univ, Dept Chem, Baton Rouge, LA 70803 USA
基金
美国国家科学基金会;
关键词
D O I
10.1016/j.jasms.2005.12.003
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
We report on the fabrication and performance of a gel microfluidic chip interfaced to laser desorption/ionization (LDI) mass spectrometry with a time-of-flight mass analyzer. The chip was fabricated from poly(methylmethacrylate) with a poly(dimethyl siloxane) cover. Sodium dodecyl sulfate-polyacrylamide gel electrophoresis was performed in the channel of the microfluidic chip. After electrophoresis, the cover was removed and either the PDMS chip or the PMMA cover was mounted in a modified MALDI ion source for analysis. Ions were formed by irradiating the channel with 2.95 mu m radiation from a pulsed optical parametric oscillator (OPO), which is coincident with IR absorption by N-H and O-H stretch of the gel components. No matrix was added. The microfluidic chip design allowed a decrease in the volume of material required for analysis over conventional gel slabs, thus enabling improvement in the detection limit to a pmol level, a three orders of magnitude improvement over previous studies in which desorption was achieved from an excised section of a conventional gel.
引用
收藏
页码:469 / 474
页数:6
相关论文
共 42 条
[1]   Infrared laser desorption and ionization of polypeptides from a polyacrylamide gel [J].
Baltz-Knorr, M ;
Ermer, DR ;
Schriver, KE ;
Haglund, RF .
JOURNAL OF MASS SPECTROMETRY, 2002, 37 (03) :254-258
[2]   A MALDI-chip integrated system with a monitoring window [J].
Brivio, M ;
Tas, NR ;
Goedbloed, MH ;
Gardeniers, HJGE ;
Verboom, W ;
van den Berg, A ;
Reinhoudt, DN .
LAB ON A CHIP, 2005, 5 (04) :378-381
[3]   Integrated microfluidic system enabling (bio)chemical reactions with on-line MALDI-TOF mass spectrometry [J].
Brivio, M ;
Fokkens, RH ;
Verboom, W ;
Reinhoudt, DN ;
Tas, NR ;
Goedbloed, M ;
van den Berg, A .
ANALYTICAL CHEMISTRY, 2002, 74 (16) :3972-3976
[4]   One step microelectroelution concentration method for efficient coupling of sodium dodecylsulfate gel electrophoresis and matrix-assisted laser desorption time-of-flight mass spectrometry for protein analysis [J].
Clarke, NJ ;
Li, F ;
Tomlinson, AJ ;
Naylor, S .
JOURNAL OF THE AMERICAN SOCIETY FOR MASS SPECTROMETRY, 1998, 9 (01) :88-91
[5]   RAPID MASS-SPECTROMETRIC PEPTIDE SEQUENCING AND MASS MATCHING FOR CHARACTERIZATION OF HUMAN-MELANOMA PROTEINS ISOLATED BY 2-DIMENSIONAL PAGE [J].
CLAUSER, KR ;
HALL, SC ;
SMITH, DM ;
WEBB, JW ;
ANDREWS, LE ;
TRAN, HM ;
EPSTEIN, LB ;
BURLINGAME, AL .
PROCEEDINGS OF THE NATIONAL ACADEMY OF SCIENCES OF THE UNITED STATES OF AMERICA, 1995, 92 (11) :5072-5076
[6]  
Doherty EAS, 2002, ELECTROPHORESIS, V23, P2766, DOI 10.1002/1522-2683(200208)23:16<2766::AID-ELPS2766>3.0.CO
[7]  
2-S
[8]   Analysis of gangliosides directly from thin-layer chromatography plates by infrared matrix-assisted laser desorption/ionization orthogonal time-of-flight mass spectrometry with a glycerol matrix [J].
Dreisewerd, K ;
Müthing, J ;
Rohlfing, A ;
Meisen, I ;
Vukelic, Z ;
Peter-Katalinic, J ;
Hillenkamp, F ;
Berkenkamp, S .
ANALYTICAL CHEMISTRY, 2005, 77 (13) :4098-4107
[9]   ELECTROSPRAY IONIZATION FOR MASS-SPECTROMETRY OF LARGE BIOMOLECULES [J].
FENN, JB ;
MANN, M ;
MENG, CK ;
WONG, SF ;
WHITEHOUSE, CM .
SCIENCE, 1989, 246 (4926) :64-71
[10]   Micromachining in plastics using X-ray lithography for the fabrication of micro-electrophoresis devices [J].
Ford, SM ;
Davies, J ;
Kar, B ;
Qi, SD ;
McWhorter, S ;
Soper, SA ;
Malek, CK .
JOURNAL OF BIOMECHANICAL ENGINEERING-TRANSACTIONS OF THE ASME, 1999, 121 (01) :13-21