Visibility of microcalcifications in computed and screen-film mammography

被引:47
作者
Cowen, AR
Launders, JH
Jadav, M
Brettle, DS
机构
[1] UNIV LEEDS, GEN INFIRM, RES SCH MED, FAXIL, LEEDS LS1 3EX, W YORKSHIRE, ENGLAND
[2] CHRISTIE HOSP NHS TRUST, N WESTERN MED PHYS DEPT, MANCHESTER M20 4BX, LANCS, ENGLAND
关键词
D O I
10.1088/0031-9155/42/8/005
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Due to the clinically and technically demanding nature of breast x-ray imaging, mammography still remains one of the few essentially film-based radiological imaging techniques in modern medical imaging. There are a range of possible benefits available if a practical and economical direct digital imaging technique can be introduced to routine clinical practice. There has been much debate regarding the minimum specification required for direct digital acquisition. One such direct digital system available is computed radiography (CR), which has a modest specification when compared with modern screen-Aim mammography (SFM) systems. This paper details two psychophysical studies in which the detection of simulated microcalcifications with CR has been directly compared to that with SFM. The first study found that under scatter-free conditions the minimum detectable size of microcalcification was approximately 130 mu m for both SFM and CR. The second study found that SFM had a 4.6% higher probability of observers being able to correctly identify the shape of 350 mu m diameter test details; there was no significant difference for either larger or smaller test details. From the results of these studies it has been demonstrated that the modest specification of CR, in terms of limiting resolution, does not translate into a dramatic difference in the perception of details at the limit of detectability. When judging the imaging performance of a system it is more important to compare the signal-to-noise ratio transfer spectrum characteristics, rather than simply the modulation transfer function.
引用
收藏
页码:1533 / 1548
页数:16
相关论文
共 47 条
[1]   NEW METHODS FOR IMAGING THE BREAST - TECHNIQUES, FINDINGS, AND POTENTIAL [J].
ADLER, DD ;
WAHL, RL .
AMERICAN JOURNAL OF ROENTGENOLOGY, 1995, 164 (01) :19-30
[2]   A CLINICAL COMPARISON BETWEEN CONVENTIONAL AND DIGITAL MAMMOGRAPHY UTILIZING COMPUTED RADIOGRAPHY [J].
BRETTLE, DS ;
WARD, SC ;
PARKIN, GJS ;
COWEN, AR ;
SUMSION, HJ .
BRITISH JOURNAL OF RADIOLOGY, 1994, 67 (797) :464-468
[3]   DUAL-ENERGY DIGITAL MAMMOGRAPHY UTILIZING STIMULATED PHOSPHOR COMPUTED RADIOGRAPHY [J].
BRETTLE, DS ;
COWEN, AR .
PHYSICS IN MEDICINE AND BIOLOGY, 1994, 39 (11) :1989-2004
[4]  
BRETTLE DS, 1994, INT CONGR SER, V1069, P163
[5]   DIGITAL MAMMOGRAPHY - ROC STUDIES OF THE EFFECTS OF PIXEL SIZE AND UNSHARP-MASK FILTERING ON THE DETECTION OF SUBTLE MICROCALCIFICATIONS [J].
CHAN, HP ;
VYBORNY, CJ ;
MACMAHON, H ;
METZ, CE ;
DOI, K ;
SICKLES, EA .
INVESTIGATIVE RADIOLOGY, 1987, 22 (07) :581-589
[6]   DIGITIZATION REQUIREMENTS IN MAMMOGRAPHY - EFFECTS ON COMPUTER-AIDED DETECTION OF MICROCALCIFICATIONS [J].
CHAN, HP ;
NIKLASON, LT ;
IKEDA, DM ;
LAM, KL ;
ADLER, DD .
MEDICAL PHYSICS, 1994, 21 (07) :1203-1211
[7]  
COLEMAN NJ, 1996, COMMUNICATION
[8]   COMPARISON OF THE LOW-CONTRAST DETECTABILITY OF A SCREEN-FILM SYSTEM AND 3RD-GENERATION COMPUTED RADIOGRAPHY [J].
COOK, LT ;
INSANA, MF ;
MCFADDEN, MA ;
HALL, TJ ;
COX, GG .
MEDICAL PHYSICS, 1994, 21 (05) :691-695
[9]   A PRELIMINARY INVESTIGATION OF THE IMAGING PERFORMANCE OF PHOTOSTIMULABLE PHOSPHOR COMPUTED RADIOGRAPHY USING A NEW DESIGN OF MAMMOGRAPHIC QUALITY-CONTROL TEST OBJECT [J].
COWEN, AR ;
BRETTLE, DS ;
COLEMAN, NJ ;
PARKIN, GJS .
BRITISH JOURNAL OF RADIOLOGY, 1992, 65 (774) :528-535
[10]  
COWEN AR, 1994, IMAGING, V6, P77