BioMEMS - Advancing the frontiers of medicine

被引:33
作者
James, Teena [1 ,2 ]
Mannoor, Manu Sebastian [1 ,2 ]
Ivanov, Dentcho V. [1 ,2 ]
机构
[1] New Jersey Inst Technol, Microelect Res Ctr, Newark, NJ 07102 USA
[2] New Jersey Inst Technol, Dept Biomed Engn, Newark, NJ 07102 USA
关键词
BioMEMS; microtechnology; medical applications;
D O I
10.3390/s8096077
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Biological and medical application of micro-electro-mechanical-systems (MEMS) is currently seen as an area of high potential impact. Integration of biology and microtechnology has resulted in the development of a number of platforms for improving biomedical and pharmaceutical technologies. This review provides a general overview of the applications and the opportunities presented by MEMS in medicine by classifying these platforms according to their applications in the medical field.
引用
收藏
页码:6077 / 6107
页数:31
相关论文
共 209 条
[1]   Bioadhesive microdevices with multiple reservoirs: a new platform for oral drug delivery [J].
Ahmed, A ;
Bonner, C ;
Desai, TA .
JOURNAL OF CONTROLLED RELEASE, 2002, 81 (03) :291-306
[2]   A MICROMACHINED SILICON SIEVE ELECTRODE FOR NERVE REGENERATION APPLICATIONS [J].
AKIN, T ;
NAJAFI, K ;
SMOKE, RH ;
BRADLEY, RM .
IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 1994, 41 (04) :305-313
[3]  
Arai F, 2001, ELECTROPHORESIS, V22, P283, DOI 10.1002/1522-2683(200101)22:2<283::AID-ELPS283>3.0.CO
[4]  
2-C
[5]   Sensitive estimation of total cholesterol in blood using Au nanowires based micro-fluidic platform [J].
Aravamudhan, Shyam ;
Kumar, Arun ;
Mohapatra, Shyam ;
Bhansali, Shekhar .
BIOSENSORS & BIOELECTRONICS, 2007, 22 (9-10) :2289-2294
[6]   Upscaling and automation of electrophysiology: Toward high throughput screening in ion channel drug discovery [J].
Asmild, M ;
Oswald, N ;
Krzywkowski, KM ;
Friis, S ;
Jacobsen, RB ;
Reuter, D ;
Taboryski, R ;
Kutchinsky, J ;
Vestergaard, RK ;
Schroder, RL ;
Sorensen, CB ;
Bech, M ;
Korsgaard, MPG ;
Willumsen, NJ .
RECEPTORS & CHANNELS, 2003, 9 (01) :49-58
[7]   IN-VIVO COMPARISON BETWEEN 2-TIP PRESSURE TRANSDUCER SYSTEMS [J].
AUBERT, AE ;
VROLIX, M ;
DEGEEST, H ;
VANDEWERF, F .
INTERNATIONAL JOURNAL OF CLINICAL MONITORING AND COMPUTING, 1995, 12 (02) :77-83
[8]   Electronic microarray analysis of 16S rDNA amplicons for bacterial detection [J].
Barlaan, EA ;
Sugimori, M ;
Furukawa, S ;
Takeuchi, K .
JOURNAL OF BIOTECHNOLOGY, 2005, 115 (01) :11-21
[9]  
BARON N, 2008, MICROSYST TECHNOL, P1
[10]  
BARTON AC, 2008, BIOSENS BIO IN PRESS