摘要
Aim To compare the cleaning effectiveness and shaping ability of Mtwo, K3, and RaCe nickel-titanium rotary instruments during the preparation of curved root canals in extracted human teeth. Methodology A total of 60 root canals of mandibular and maxillary molars with curvatures ranging between 25 degrees and 35 degrees were divided into three groups of 20 canals. Based on radiographs taken prior to instrumentation with the initial instrument inserted into the canal, the groups were balanced with respect to the angle and the radius of canal curvature. Canals were prepared using a low-torque control motor. Using pre- and post-instrumentation radiographs, straightening of the canal curvatures was determined with a computer image analysis program. The amount of debris and smear layer was quantified on the basis of a numerical evaluation scale. The data established for scoring the debris and the smear layer was separately recorded and analysed statistically using the Kruskal-Wallis test. Results During preparation no instrument separated. Completely clean root canals were never observed. For debris removal Mtwo instruments achieved significantly better results (P < 0.001) than K3 and RaCe instruments. The results for remaining smear layer were similar and not significantly different (P > 0.05). Mtwo instruments maintained the original canal curvature significantly better (P < 0.05) than the other instruments. Instrumentation with Mtwo files was significantly faster than with K3 or RaCe instruments (P < 0.05). Conclusions Under the conditions of this study, Mtwo instruments resulted in good cleaning and maintained the original curvature significantly better than K3 or RaCe files.
引用
收藏
页码:203 / 212
页数:10
相关论文
共 30 条
[1]  
*AM ASS END, 1998, GLOSS CONT TERM END
[2]   K3 endo, ProTaper, and ProFile systems: Breakage and distortion, in severely curved roots of molars [J].
Ankrum, MT ;
Hartwell, GR ;
Truitt, JE .
JOURNAL OF ENDODONTICS, 2004, 30 (04) :234-237
[3]  
[Anonymous], 1994, Int Endod J, V27, P115
[4]   Shaping ability of ProFile and K3 rotary Ni-Ti instruments when used in a variable tip sequence in simulated curved root canals [J].
Ayar, LR ;
Love, RM .
INTERNATIONAL ENDODONTIC JOURNAL, 2004, 37 (09) :593-601
[5]  
Bolanos O R, 1980, J Endod, V6, P815, DOI 10.1016/S0099-2399(80)80034-3
[6]   SEM evaluation of canal wall dentine following use of Mtwo and ProTaper NiTi rotary instruments [J].
Foschi, F ;
Nucci, C ;
Montebugnoli, L ;
Marchionni, S ;
Breschi, L ;
Malagnino, VA ;
Prati, C .
INTERNATIONAL ENDODONTIC JOURNAL, 2004, 37 (12) :832-839
[7]   A scanning electron microscopic study of debris and smear layer remaining following use of GT rotary instruments [J].
Gambarini, G ;
Laszkiewicz, J .
INTERNATIONAL ENDODONTIC JOURNAL, 2002, 35 (05) :422-427
[8]   Shaping and cleaning the root canal system: A scanning electron microscopic evaluation of a new instrumentation and irrigation technique [J].
Gambarini, G .
JOURNAL OF ENDODONTICS, 1999, 25 (12) :800-803
[9]   Evaluation of glyde file prep in combination with sodium hypochlorite as a root canal irrigant [J].
Grandini, S ;
Balleri, P ;
Ferrari, M .
JOURNAL OF ENDODONTICS, 2002, 28 (04) :300-303
[10]   Evaluation of smear layer removal by EDTAC and sodium hypochlorite with ultrasonic agitation [J].
Guerisoli, DMZ ;
Marchesan, MA ;
Walmsley, AD ;
Lumley, PJ ;
Pecora, JD .
INTERNATIONAL ENDODONTIC JOURNAL, 2002, 35 (05) :418-421