Direct and LC analysis of five benzodiazepines in human urine plasma using an ADS restricted access extraction column

被引:56
作者
Mullett, WM [1 ]
Pawliszyn, J [1 ]
机构
[1] Univ Waterloo, Dept Chem, Waterloo, ON N2L 3G1, Canada
关键词
benzodiazepine analysis; ADS extraction precolumn; direct injection; reverse-phase chromatography; serum; urine;
D O I
10.1016/S0731-7085(01)00461-7
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
An alkyl-diol-silica (ADS) precolumn was used for the direct and on-line extraction of several benzodiazepines from serum and urine. The protein component of the biological sample was flushed through the ADS column, while simultaneously extracting the benzodiazepine compounds in the pores of the ADS stationary phase, The role of hydrophobic interactions in the extraction mechanism was confirmed. Column switching was employed to elute the extracted analytes from the ADS column into a high-performance liquid chromatography reverse-phase C18 column for the isocratic separation and UV detection of the benzodiazepines. Sample preconcentration via large volume injections was possible, improving the limits of detection. The calculated clonazepam, oxazepam, temazepam, nordazepam and diazepam detection limits were 38.8, 24.2, 31.7, 31.3, 45.0 ng/ml in serum, respectively, and 48.4, 24.5, 31.7, 33.1, 52.9 ng/ml for urine, respectively. The method was linear over the range of 50-10000 ng/ml in both matrices with an average linear coefficient (R-2) value of 0.9918. The injection repeatability and intra-assay precision of the method were evaluated over ten injections, resulting in a percent relative standard deviation < 5%. The ADS extraction column was robust, providing many direct injections of biological fluids for the extraction and subsequent determination of benzodiazepines. (C) 2001 Elsevier Science B.V. All rights reserved.
引用
收藏
页码:899 / 908
页数:10
相关论文
共 34 条
[21]  
Majors RE, 1996, LC GC-MAG SEP SCI, V14, P554
[22]  
*MERCK KGAA, 1999, LICHR ADS APPL GUID
[23]  
Mislanová C, 2000, J CHROMATOGR B, V739, P151
[24]  
MORI A, 1993, ACTA CRIM JAPON, V59, P200
[25]   Benzodiazepine findings in blood and urine by gas chromatography and immunoassay [J].
Rasanen, I ;
Neuvonen, M ;
Ojanperä, I ;
Vuori, E .
FORENSIC SCIENCE INTERNATIONAL, 2000, 112 (2-3) :191-200
[26]  
Reubsaet KJ, 1998, J PHARMACEUT BIOMED, V18, P667
[27]   DETERMINATION OF DIAZEPAM AND NORDAZEPAM IN MILK AND PLASMA IN THE PRESENCE OF OXAZEPAM AND TEMAZEPAM [J].
STEBLER, T ;
GUENTERT, TW .
JOURNAL OF CHROMATOGRAPHY-BIOMEDICAL APPLICATIONS, 1991, 564 (01) :330-337
[28]  
SZEPESI G, 1992, USE REVERSE PHASE HP, P67
[29]   DEATH CAUSED BY TRIAZOLAM AND ETHANOL INTOXICATION [J].
UEMURA, K ;
KOMURA, S .
AMERICAN JOURNAL OF FORENSIC MEDICINE AND PATHOLOGY, 1995, 16 (01) :66-68
[30]   Coupling device for desorption of drugs from solid-phase extraction-pipette tips and on-line gas chromatographic analysis [J].
van Hout, MWJ ;
de Zeeuw, RA ;
de Jong, GJ .
JOURNAL OF CHROMATOGRAPHY A, 1999, 858 (01) :117-122