Non-invasive cardiac output measure end in low and very low birth weight infants: a method comparison

被引:45
作者
Grollmuss, Oswin [1 ]
Gonzalez, Patricia [2 ]
机构
[1] Univ Paris XI Sud, INSERM 999, Ctr Chirurg Marie Lannelongue, 133 Ave Resistance, F-92350 Orsay, France
[2] Univ Paris V Descartes, Inst Puericulture & Perinatal, Clamart, France
关键词
low birth weight infants; very low birth weight infants; neonatal intensive care unit; pediatric cardiac intensive care unit; stroke volume; cardiac output; electrical velocimetry; transthoracic echocardiograph;
D O I
10.3389/fped.2014.00016
中图分类号
R72 [儿科学];
学科分类号
100202 [儿科学];
摘要
Background: Cardiac output (CO) measurement in low (LBW) and very low (VLBW) birth weight infants is difficult. Hitherto, sporadical transthoracic echocardiography (TTE) is the only non-invasive measurement method. Electrical velocimetry (EV) has been evaluated as an alternative in normal weight newborns. Objectives: The study was designed to evaluate if EV could be interchangeable with TTE even in LBW and VLBW infants. Methods: In 28 (17 LBW, 11 VLBW) pre-mature newborns, n = 228 simultaneous TTE (trans-aortic Doppler), and EV measurements (134 LBW, 94 VLBW) of stroke volume (SV) and heart rate (HR) were performed, thereof calculating body weight indexed SV (=SV*) and CO (=CO*) for all patients and the subgroups. Method comparison was performed by Bland Altman plot, method precision expressed by calculation of the coefficient of variation (CV). Results: Mean CO* in all patients was 256.4 +/- 44.8 (TTE) and 265.3 +/- 48.8 (EV) ml/kg/min. Bias and precision were clinically acceptable, limits of agreement within the 30% criterion for method interchangeability (17). According to their different anatomic dimensions and pathophysiology, there were significant differences of SV(*), HR, and CO* for LBW and VLBW infants as well for inotropic treatment and ventilation mode. Conclusion: Extending recent publications on EV/TTE comparison in newborns, this study suggests that EV is also applicable in LWBNLBW infants as a safe and easy to handle method for continuous CO monitoring in the NICU and PCICU.
引用
收藏
页数:5
相关论文
共 19 条
[1]
Stroke volume equation for impedance cardiography [J].
Bernstein, DP ;
Lemmens, HJM .
MEDICAL & BIOLOGICAL ENGINEERING & COMPUTING, 2005, 43 (04) :443-450
[2]
STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT [J].
BLAND, JM ;
ALTMAN, DG .
LANCET, 1986, 1 (8476) :307-310
[3]
A meta-analysis of studies using bias and precision statistics to compare cardiac output measurement techniques [J].
Critchley, LAH ;
Critchley, JAJH .
JOURNAL OF CLINICAL MONITORING AND COMPUTING, 1999, 15 (02) :85-91
[4]
Electrical velocimetry as a tool for measuring cardiac output in small infants after heart surgery [J].
Grollmuss, Oswin ;
Demontoux, Serge ;
Capderou, Andre ;
Serraf, Alain ;
Belli, Emre .
INTENSIVE CARE MEDICINE, 2012, 38 (06) :1032-1039
[5]
REPRODUCIBILITY OF MEASUREMENTS OF CARDIAC-OUTPUT IN NEWBORN-INFANTS BY DOPPLER ULTRASOUND [J].
HUDSON, I ;
HOUSTON, A ;
AITCHISON, T ;
HOLLAND, B ;
TURNER, T .
ARCHIVES OF DISEASE IN CHILDHOOD-FETAL AND NEONATAL EDITION, 1990, 65 (01) :15-19
[6]
KUBICEK WG, 1966, AEROSPACE MED, V37, P1208
[7]
Near infrared spectroscopy in children at high risk of low perfusion [J].
Mittnacht, Alexander J. C. .
CURRENT OPINION IN ANESTHESIOLOGY, 2010, 23 (03) :342-347
[8]
Continuous non-invasive cardiac output measurements in the neonate by electrical velocimetry: a comparison with echocardiography [J].
Noori, Shahab ;
Drabu, Benazir ;
Soleymani, Sadaf ;
Seri, Istvan .
ARCHIVES OF DISEASE IN CHILDHOOD-FETAL AND NEONATAL EDITION, 2012, 97 (05) :F340-F343
[9]
Electrical velocimetry for measuring cardiac output in children with congenital heart disease [J].
Norozi, K. ;
Beck, C. ;
Osthaus, W. A. ;
Wille, I. ;
Wessel, A. ;
Bertram, H. .
BRITISH JOURNAL OF ANAESTHESIA, 2008, 100 (01) :88-94
[10]
A standard protocol for blood pressure measurement in the newborn [J].
Nwankwo, MU ;
Lorenz, JM ;
Gardiner, JC .
PEDIATRICS, 1997, 99 (06) :art. no.-e10