Intracardiac echocardiography in the interventional catheterization laboratory: Preliminary experience with a novel, phased-array transducer

被引:17
作者
Bruce, CJ [1 ]
Nishimura, RA [1 ]
Rihal, CS [1 ]
Hagler, DJ [1 ]
Higano, ST [1 ]
Seward, JB [1 ]
Holmes, DR [1 ]
机构
[1] Mayo Clin & Mayo Fdn, Div Cardiovasc Dis & Internal Med, Rochester, MN 55905 USA
关键词
D O I
10.1016/S0002-9149(01)02316-5
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
To date, intracardiac ultrasonographic guidance of interventional procedures has been limited.(1,2) The major limitation has been the poor depth of penetration of the transducers. Either catheters have had transducers with lower frequency (and thus enhanced depth penetration) that require mounting on catheters with large-bore caliber or the catheters have had smaller, higher frequency transducers that make visualization of left-sided structures impossible with the imaging catheter in the right side of the heart. Also, except for the phased-array catheter of our study, available catheters cannot provide hemodynamic assessment because they lack Doppler capabilities. Recently, a phased-array intracardiac echocardiographic catheter was introduced that has a range of frequencies (5.5 to 10 MHz) and full Doppler capability (pulsed,continuous-wave, color flow, and tissue Doppler).(3,4) Thus, this new generation imaging catheter may overcome the limitations of other available intracardiac catheters. We present preliminary results of the utility of this novel intracardiac echocardiographic catheter during interventional procedures in the cardiac catheterization laboratory.
引用
收藏
页码:635 / +
页数:7
相关论文
共 14 条
[1]   Intracardiac Doppler hemodynamics and flow: New vector, phased-array ultrasound-tipped catheter [J].
Bruce, CJ ;
Packer, DL ;
Seward, JB .
AMERICAN JOURNAL OF CARDIOLOGY, 1999, 83 (10) :1509-+
[2]   INTRACARDIAC ECHOCARDIOGRAPHY DURING RADIOFREQUENCY CATHETER ABLATION OF CARDIAC-ARRHYTHMIAS IN HUMANS [J].
CHU, E ;
KALMAN, JM ;
KWASMAN, MA ;
JUE, JCY ;
FITZGERALD, PJ ;
EPSTEIN, LM ;
SCHILLER, NB ;
YOCK, PG ;
LESH, MD .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1994, 24 (05) :1351-1357
[3]   Transcatheter closure of atrial septal defects without fluoroscopy - Feasibility of a new method [J].
Ewert, P ;
Berger, F ;
Daehnert, I ;
van Wees, J ;
Gittermann, M ;
Abdul-Khaliq, H ;
Lange, PE .
CIRCULATION, 2000, 101 (08) :847-849
[4]   Usefulness of intracardiac echocardiography in complex transseptal catheterization during percutaneous transvenous mitral commissurotomy [J].
Hung, JS ;
Fu, M ;
Yeh, KH ;
Wu, CJ ;
Wong, P .
MAYO CLINIC PROCEEDINGS, 1996, 71 (02) :134-140
[5]  
Hurrell DG, 1998, MAYO CLIN PROC, V73, P126
[6]   Use of intracardiac echocardiography in interventional electrophysiology [J].
Kalman, JM ;
Olgin, JE ;
Karch, MR ;
Lesh, MD .
PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 1997, 20 (09) :2248-2262
[7]  
Miyamoto N, 1995, J Cardiol, V25, P29
[8]  
PANDIAN NG, 1992, AM J CARDIOL, V69, P6
[9]   Lower frequency (5 MHz) intracardiac echocardiography in a large swine model: Imaging views and research applications [J].
Ren, JF ;
Schwartzman, D ;
Michele, JJ ;
Li, KS ;
Hoffmann, J ;
Brode, SE ;
Lighty, GW ;
Dillon, SM ;
Chaudhry, FA .
ULTRASOUND IN MEDICINE AND BIOLOGY, 1997, 23 (06) :871-877
[10]   INTRACARDIAC ECHOCARDIOGRAPHY DURING SIMULATED AORTIC AND MITRAL BALLOON VALVULOPLASTY - INVIVO EXPERIMENTAL STUDIES [J].
SCHWARTZ, SL ;
PANDIAN, NG ;
KUMAR, R ;
KATZ, SE ;
KUSAY, BS ;
ARONOVITZ, M ;
KONSTAM, MA ;
SALEM, DN .
AMERICAN HEART JOURNAL, 1992, 123 (03) :665-674