Retrievable IVC square stent filter:: Experimental study

被引:16
作者
Pavcnik, D [1 ]
Uchida, BT [1 ]
Keller, FS [1 ]
Corless, CL [1 ]
Rösch, J [1 ]
机构
[1] Oregon Hlth Sci Univ, Dotter Intervent Inst, Portland, OR 97201 USA
关键词
embolism; pulmonary; inferior vena cava; filters; interventional procedures; experimental; in vitro studies; in vivo studies;
D O I
10.1007/s002709900374
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Purpose: In vitro and in vivo evaluation of a new retrievable, home-made, inferior vena cava (IVC) Square stent filter (SSF) with two trapping levels. Methods: In vitro, the SSF was compared in a flow model with the stainless steel Greenfield filter (SGF) for emboli-trapping efficiency by serially passing 300 emboli of 3 and 6 mm in diameter and 15-30 mm in length in each type of filter. Nine swine were used for the in vivo testing of the SSF for deployment and retrievability, emboli-trapping efficiency, stability, and self-centering ability and two were used (total of II swine) for testing repositioning and retrievability of the SSF at 2 weeks and for gross and histologic IVC changes at 2 months. Results: In vitro, the SSF and SGF had similar efficiency in trapping large emboli but the SSF had significantly better efficiency than the SGF for trapping all sizes of emboli (91.7% vs 81%), medium size emboli (93% vs 80%), and small emboli (86% vs 69%). Efficiency decreased in both filters from the first to the fifth embolus in each series but was still significantly better for the SSF. With the SSF, 89% of emboli were caught at the primary and 11% at the secondary filtration level. In the nine animals used for acute studies, the SSF was easily placed in all 27 attempts, assumed a central position 26 times, and was easily retrieved in 21 of 22 attempts. One tilted filter needed additional manipulation for retrieval. During emboli injection in five swine, the SSF had 97.2% emboli-napping efficiency and demonstrated good stability. In the two animals used for longer-term evaluation, the filters were easily retrieved 2 weeks after implantation. Histologic evaluation at 2 months showed neointimal proliferation around the SSF wires in contact with the IVC wall, which was otherwise normal. Conclusion: The SSF is a promising filter. It is easy to place and retrieve, is stable after placement, and has high efficiency for trapping emboli. Promising results justify further experimental and eventual clinical studies with a commercially manufactured SSF.
引用
收藏
页码:239 / 245
页数:7
相关论文
共 25 条
  • [1] The Tempofilter((R)): A multicenter study of a new temporary caval filter implantable for up to six weeks
    Bovyn, G
    Gory, P
    Reynaud, P
    Ricco, JB
    [J]. ANNALS OF VASCULAR SURGERY, 1997, 11 (05) : 520 - 528
  • [2] Temporary use of a Bird's Nest filter during iliocaval thrombolysis
    Cope, C
    Baum, RA
    Duszak, RA
    [J]. RADIOLOGY, 1996, 198 (03) : 765 - 767
  • [3] EXPERIENCE WITH THE AMPLATZ RETRIEVABLE VENA-CAVAL FILTER - WORK IN PROGRESS
    DARCY, MD
    CARDELLA, JF
    HUNTER, DW
    SMITH, TP
    CASTANEDAZUNIGA, WR
    LUND, G
    AMPLATZ, K
    [J]. RADIOLOGY, 1986, 161 (03) : 611 - 614
  • [4] In vivo evaluation of a retrievable vena cava filter - The Dibie-Musset filter: Experimental results
    Dibie, A
    Musset, D
    Heissler, M
    Fournet, JC
    Palau, R
    Laborde, F
    [J]. CARDIOVASCULAR AND INTERVENTIONAL RADIOLOGY, 1998, 21 (02) : 151 - 157
  • [5] PERCUTANEOUS INFERIOR VENA-CAVAL FILTERS
    DORFMAN, GS
    [J]. RADIOLOGY, 1990, 174 (03) : 987 - 992
  • [6] EXPERIENCE WITH THE AMPLATZ RETRIEVABLE VENA-CAVA FILTER
    EPSTEIN, DH
    DARCY, MD
    HUNTER, DW
    COLEMAN, CC
    TADAVARTHY, SM
    MURRAY, PD
    CASTANEDAZUNIGA, WR
    AMPLATZ, K
    [J]. RADIOLOGY, 1989, 172 (01) : 105 - 110
  • [7] INFERIOR VENA-CAVAL FILTERS - ANALYSIS OF 5 CURRENTLY AVAILABLE DEVICES
    GRASSI, CJ
    [J]. AMERICAN JOURNAL OF ROENTGENOLOGY, 1991, 156 (04) : 813 - 821
  • [8] GREEN J, 1994, MINER ELECTROL METAB, V20, P5
  • [9] In vitro function of an adjustable temporary venous spring filter: Comparison with the temporary RF02 filter and the permanent greenfield vena cava filter
    Hosaka, J
    Roy, S
    Kvernebo, K
    Enge, I
    Laerum, F
    [J]. ACADEMIC RADIOLOGY, 1998, 5 (09) : 620 - 625
  • [10] Hunter D W, 1987, Cardiovasc Intervent Radiol, V10, P32, DOI 10.1007/BF02583304