Effect of patient weight and scanning duration on contrast enhancement during pulmonary multidetector CT angiography

被引:84
作者
Bae, Kyongtae T.
Tao, Cheng
Gurel, Safiye
Hong, Cheng
Zhu, Fang
Gebke, Todd A.
Milite, Margherita
Hildebolt, Charles F.
机构
[1] Univ Pittsburgh, Sch Med, Dept Radiol, Pittsburgh, PA 15213 USA
[2] Washington Univ, Mallinckrodt Inst Radiol, Sch Med, St Louis, MO 63130 USA
[3] Abant Izzet Baysal Univ, Sch Med, Dept Radiol, Golkoy Bolu, Turkey
[4] Siemens Med Syst Inc, Iselin, NJ USA
关键词
D O I
10.1148/radiol.2422052132
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: To retrospectively evaluate the amount of contrast medium required with 16- and 64-section computed tomography (CT) for a given patient weight to achieve desirable contrast enhancement during pulmonary CT angiography. Materials and Methods: Institutional review board approval was obtained, and informed consent was not required for this HIPAA-compliant study. Eighty-five patients (35 men, 50 women; range, 22 - 87 years) who had undergone 16- section (n = 48) or 64-section (n = 37) CT for the detection of pulmonary embolism were retrospectively evaluated. Contrast medium containing 350 mg of iodine per milliliter was injected at a rate of 4 mL/sec. The injected volume corresponded to the injection rate multiplied by the sum of the scanning delay plus the scanning duration, up to 125 mL. The scanning delay was determined with bolus tracking. Contrast enhancement was measured in the main pulmonary artery and the aorta. For each patient, the injected contrast medium volume per body weight index was calculated. Linear regression analysis was performed, and the Wilcoxon signed rank test was used to assess differences between 16- and 64-section CT. Results: A range of patient weights (45.3-153.0 kg) and contrast medium volumes (76 - 125 mL) were noted. The regression formula indicated that 1.2 mL per kilogram body weight of contrast medium was required to achieve 250 HU. The median scanning duration was shorter for 64-section CT than for 16- section CT (5.7 seconds vs 9.5 seconds, P < .001).Consequently, 64-section CT required 17.6% less contrast medium than did 16- section CT (85.4 mL vs 103.6 mL, P < .001). Median contrast enhancement in the pulmonary artery was 8.9% lower with 64-section CT than with 16- section CT (257.7 HU vs 282.9 HU, P = .11). Conclusion: To achieve consistent contrast enhancement during pulmonary CT angiography, the amount of contrast medium can be adjusted to the patient's body weight.
引用
收藏
页码:582 / 589
页数:8
相关论文
共 26 条
[1]   Test-bolus versus bolus-tracking techniques for CT angiographic timing [J].
Bae, KT .
RADIOLOGY, 2005, 236 (01) :369-370
[2]   Peak contrast enhancement in CT and MR angiography: When does it occur and why? Pharmacokinetic study in a porcine model [J].
Bae, KT .
RADIOLOGY, 2003, 227 (03) :809-816
[3]   Aortic and hepatic contrast medium enhancement at CT part II. Effect of reduced cardiac output in a porcine model [J].
Bae, KT ;
Heiken, JP ;
Brink, JA .
RADIOLOGY, 1998, 207 (03) :657-662
[4]   Aortic and hepatic peak enhancement at CT: Effect of contrast medium injection rate - Pharmacokinetic analysis and experimental porcine model [J].
Bae, KT ;
Heiken, JP ;
Brink, JA .
RADIOLOGY, 1998, 206 (02) :455-464
[5]  
Bae KT, 2003, APPL RADIOL, V32, P12, DOI [10.1007/88-470-0413-6_2, DOI 10.1007/88-470-0413-6_2]
[6]   COMPARISON OF CONTRAST-MEDIA INJECTION RATES AND VOLUMES FOR HEPATIC DYNAMIC INCREMENTED COMPUTED-TOMOGRAPHY [J].
BERLAND, LL ;
LEE, JY .
INVESTIGATIVE RADIOLOGY, 1988, 23 (12) :918-922
[7]   Assessment of a bolus-traching technique in helical renal CT to optimize nephrographic phase imaging [J].
Birnbaum, BA ;
Jacobs, JE ;
Langlotz, CP ;
Ramchandani, P .
RADIOLOGY, 1999, 211 (01) :87-94
[8]   Intravenous contrast material administration at 16-detector row helical CT coronary angiography: Test bolus versus bolus-tracking technique [J].
Cademartiri, F ;
Nieman, K ;
van der Lugt, A ;
Raaijmakers, RH ;
Mollet, N ;
Pattynama, PMT ;
de Feyter, PJ ;
Krestin, GP .
RADIOLOGY, 2004, 233 (03) :817-823
[9]   HEPATIC CT ENHANCEMENT .1. ALTERATIONS IN THE VOLUME OF CONTRAST MATERIAL WITHIN THE SAME PATIENTS [J].
CHAMBERS, TP ;
BARON, RL ;
LUSH, RM .
RADIOLOGY, 1994, 193 (02) :513-517
[10]   HEPATIC CT CONTRAST ENHANCEMENT - EFFECT OF DOSE, DURATION OF INFUSION, AND TIME ELAPSED FOLLOWING INFUSION [J].
DEAN, PB ;
VIOLANTE, MR ;
MAHONEY, JA .
INVESTIGATIVE RADIOLOGY, 1980, 15 (02) :158-161