Accuracy and reliability of noninvasive continuous finger blood pressure measurement in critically ill patients

被引:33
作者
Hirschl, MM [1 ]
Binder, M [1 ]
Herkner, H [1 ]
Bur, A [1 ]
Brunner, M [1 ]
Seidler, D [1 ]
Stuhlinger, HG [1 ]
Laggner, AN [1 ]
机构
[1] UNIV VIENNA,DEPT DERMATOL,VIENNA,AUSTRIA
关键词
arterial pressure; noninvasive monitoring; blood pressure measurement; critical illness; emergency measurement;
D O I
10.1097/00003246-199610000-00014
中图分类号
R4 [临床医学];
学科分类号
1002 ; 100602 ;
摘要
Objective: To evaluate the accuracy and reliability of noninvasive continuous finger blood pressure measurement in critically ill patients. Design: Prospective data collection. Setting: Emergency department in a 2,000-bed hospital. Patients: Thirty-nine patients admitted to the emergency department requiring invasive arterial blood pressure monitoring were enrolled to the study protocol. Interventions: Continuous noninvasive blood pressure measurement was performed on the middle phalanx of the second and third finger, using a test instrument which provides continuous arterial waveform display with the use of a finger cuff. Invasive mean arterial blood pressure measurement was done by cannula tion of the radial artery and direct transduction of the systemic arterial pressure waveform. Measurements and Main Results: Three thousand one hundred eighteen pairs of simultaneous finger cuff and intra-arterial blood pressure measurements were collected in 1-min intervals from 39 patients over a total of 51.8 hrs. The overall discrepancy between both measurements was 0.10 mm Hg. The standard deviation of the differences was +/-5.02 mm Hg. The mean bias in patients treated with catecholamines was 0.01 mm Hg and was not different from the bias observed in patients without catecholamines (mean bias: 0.23 mm Hg; p > .22). Whereas 95% of all comparisons between finger cuff and intra arterial measurement had a discrepancy less than or equal to+/-10 mm Hg, 4.7% had a discrepancy between +/-10.1 to 15 mm Hg and 0.3% exhibited a discrepancy >+/-15 mm Hg. In 29 (74%) patients, the duration of errors >10 mm Hg was less than or equal to 1 min. In seven (18%) patients, the duration of errors >10 mm Hg was between 2 to 3 mins and in three (8%) patients, the errors lasted for >3 mins. Conclusions: Our data provide a guide to the accuracy and reliability of noninvasive finger blood pressure measurements in critically ill patients. Although most test instrument measurements were reliable, in 8% of all patients large discrepancies (>10 mm Hg) between both measurements with a duration of >3 mins were noted. Concerning the considerable risk for arterial cannulation, our preliminary data demonstrate that the test instrument (PORTAPRES(R) TNO Biomedical Instrumentation Research Unit; The Netherlands) is an advance in noninvasive monitoring of critically ill patients and may be useful in most emergency clinical settings.
引用
收藏
页码:1684 / 1689
页数:6
相关论文
共 25 条
  • [1] [Anonymous], 1990, BLOOD PRESSURE MEASU
  • [2] Armitage P, 1987, Statistical methods in medical research, V2nd
  • [3] STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT
    BLAND, JM
    ALTMAN, DG
    [J]. LANCET, 1986, 1 (8476) : 307 - 310
  • [4] OSLER NODES, PSEUDOANEURYSM FORMATION, AND SEPSIS COMPLICATING PERCUTANEOUS RADIAL ARTERY CANNULATION
    COHEN, A
    REYES, R
    KIRK, M
    FULKS, RM
    [J]. CRITICAL CARE MEDICINE, 1984, 12 (12) : 1078 - 1079
  • [5] ARTERIAL-OCCLUSION AFTER CANNULATION
    EVANS, PJD
    KERR, JH
    [J]. BRITISH MEDICAL JOURNAL, 1975, 3 (5977) : 197 - 199
  • [6] DIRECT BLOOD-PRESSURE MEASUREMENT - DYNAMIC-RESPONSE REQUIREMENTS
    GARDNER, RM
    [J]. ANESTHESIOLOGY, 1981, 54 (03) : 227 - 236
  • [7] THE ACCURACY OF FINAPRES NONINVASIVE MEAN ARTERIAL-PRESSURE MEASUREMENTS IN ANESTHETIZED PATIENTS
    GIBBS, NM
    LARACH, DR
    DERR, JA
    [J]. ANESTHESIOLOGY, 1991, 74 (04) : 647 - 652
  • [8] IMHOLZ BPM, 1992, J HYPERTENS, V10, P979
  • [9] NONINVASIVE CONTINUOUS FINGER BLOOD-PRESSURE MEASUREMENT DURING ORTHOSTATIC STRESS COMPARED TO INTRAARTERIAL PRESSURE
    IMHOLZ, BPM
    SETTELS, JJ
    VANDERMEIRACKER, AH
    WESSELING, KH
    WIELING, W
    [J]. CARDIOVASCULAR RESEARCH, 1990, 24 (03) : 214 - 221
  • [10] FEASIBILITY OF AMBULATORY, CONTINUOUS 24-HOUR FINGER ARTERIAL-PRESSURE RECORDING
    IMHOLZ, BPM
    LANGEWOUTERS, GJ
    VANMONTFRANS, GA
    PARATI, G
    VANGOUDOEVER, J
    WESSELING, KH
    WIELING, W
    MANCIA, G
    [J]. HYPERTENSION, 1993, 21 (01) : 65 - 73