A reagentless amperometric sensor highly sensitive to H2O2 has been prepared by incorporating fumed silica, horseradish peroxidase (HRP) and Meldola Blue into carbon paste. The efficient mediating ability to shift electrons between HRP and the carbon paste electrode via Meldola Blue was investigated by cyclic voltammetric and amperometric measurements. Reproducibility, response time, detection limit, selectivity and effects of applied potential, temperature and pH on the response of the sensor are reported. The high sensitivity of the sensor with a detection limit of 0.1 mu mol/l arose from the high efficiency of the bioelectrocatalytic reduction of hydrogen peroxide via HRP and Meldola Blue. The dependence of the Michaelis-Menten constant on the applied potential and the mediator concentration has been investigated and the results are presented.
引用
收藏
页码:297 / 301
页数:5
相关论文
共 26 条
[1]   TTF-MODIFIED BIOSENSORS FOR HYDROGEN-PEROXIDE [J].
BIFULCO, L ;
CAMMAROTO, C ;
NEWMAN, JD ;
TURNER, APF .
ANALYTICAL LETTERS, 1994, 27 (08) :1443-1452
[2]   BIOAMPEROMETRIC SENSORS FOR PHENOL BASED ON CARBON PASTE ELECTRODES [J].
BONAKDAR, M ;
VILCHEZ, JL ;
MOTTOLA, HA .
JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 1989, 266 (01) :47-55
[3]   AMPEROMETRIC DETERMINATION OF DOPAMINE ON AN ENZYMATICALLY MODIFIED CARBON-PASTE ELECTRODE [J].
FORZANI, ES ;
RIVAS, GA ;
SOLIS, VM .
JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 1995, 382 (1-2) :33-40
[4]   A METHOD FOR ESTIMATION OF HYDROGEN-PEROXIDE BASED ON MEDIATED ELECTRON-TRANSFER REACTIONS OF PEROXIDASES AT ELECTRODES [J].
FREW, JE ;
HARMER, MA ;
HILL, HAO ;
LIBOR, SI .
JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 1986, 201 (01) :1-10
[5]   AMPEROMETRIC SENSORS FOR PEROXIDE, CHOLINE, AND ACETYLCHOLINE BASED ON ELECTRON-TRANSFER BETWEEN HORSERADISH-PEROXIDASE AND A REDOX POLYMER [J].
GARGUILO, MG ;
HUYNH, N ;
PROCTOR, A ;
MICHAEL, AC .
ANALYTICAL CHEMISTRY, 1993, 65 (05) :523-528
[6]   DIRECT ELECTROCHEMISTRY OF PROTEINS AND ENZYMES [J].
GUO, LH ;
HILL, HAO .
ADVANCES IN INORGANIC CHEMISTRY, 1991, 36 :341-375
[7]   ACCURACY OF DETERMINATION OF HYDROGEN PEROXIDE BY CERATE OXIDIMETRY [J].
HURDIS, EC ;
ROMEYN, H .
ANALYTICAL CHEMISTRY, 1954, 26 (02) :320-325
[8]   ROTATING-RING-DISK ENZYME ELECTRODE FOR BIOCATALYSIS KINETIC-STUDIES AND CHARACTERIZATION OF THE IMMOBILIZED ENZYME LAYER [J].
KAMIN, RA ;
WILSON, GS .
ANALYTICAL CHEMISTRY, 1980, 52 (08) :1198-1205
[9]   NOVEL MEMBRANELESS AMPEROMETRIC PEROXIDE BIOSENSOR BASED ON A TETRATHIAFULVALENE-P-TETRACYANOQUINODIMETHANE ELECTRODE [J].
KORELL, U ;
SPICHIGER, UE .
ANALYTICAL CHEMISTRY, 1994, 66 (04) :510-515
[10]   MEDIATORLESS PEROXIDASE ELECTRODE AND PREPARATION OF BIENZYME SENSORS [J].
KULYS, J ;
SCHMID, RD .
BIOELECTROCHEMISTRY AND BIOENERGETICS, 1990, 24 (03) :305-311