Contrast-enhanced CT with saline flush technique using two automated injectors: How much contrast medium does it save?

被引:39
作者
Irie, T [1 ]
Kajitani, M [1 ]
Yamaguchi, M [1 ]
Itai, Y [1 ]
机构
[1] Univ Tsukuba, Inst Clin Med, Dept Radiol, Tsukuba, Ibaraki 305, Japan
关键词
computed tomography; contrast enhancement;
D O I
10.1097/00004728-200203000-00022
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: The purpose of this work was to investigate the volume of contrast medium saved by the saline flush technique. Method: Thoracic helical CT was performed by injecting 75 ml of contrast material (loversol 320) only (n = 25; Group A) or 75 ml of contrast medium pushed with 6 ml (n = 25; Group B), 12 ml (n = 25 Group C), 25 ml (n = 25, Group D), or 50 ml (n = 25; Group E) of saline at a rate of 2 ml/s. The aortic CT numbers were measured from 30 to 55 s after the beginning of injection. We compared the time to peak aortic enhancement (TPAE) among Groups A-E. Results: The TPAEs of the Groups A-E were 42.6, 45.2, 48.6, 48,4, and 48.3 s. respectively, and there was a statistically significant difference among them (p < 0.0001, analysis of variance). Post hoc test revealed statistically significant differences in TPAE between Groups A and B, C, D, and E and between Groups B and C, D, and E but no differences among Groups C, D, and E. Conclusion: The saline flush technique prolongs TPAE by 6 s and saves 12 ml of contrast medium.
引用
收藏
页码:287 / 291
页数:5
相关论文
共 7 条
[1]   Aortic and hepatic contrast medium enhancement at CT part I. Prediction with a computer model [J].
Bae, KT ;
Heiken, JP ;
Brink, JA .
RADIOLOGY, 1998, 207 (03) :647-655
[2]   Hepatic arterial-phase dynamic gadolinium-enhanced MR imaging: Optimization with a test examination and a power injector [J].
Earls, JP ;
Rofsky, NM ;
DeCorato, DR ;
Krinsky, GA ;
Weinreb, JC .
RADIOLOGY, 1997, 202 (01) :268-273
[3]   Reduction of contrast material dose and artifacts by a saline flush using a double power injector in helical CT of the thorax [J].
Haage, P ;
Schmitz-Rode, T ;
Hübner, D ;
Piroth, W ;
Günther, RW .
AMERICAN JOURNAL OF ROENTGENOLOGY, 2000, 174 (04) :1049-1053
[4]   Optimization of contrast timing for breath-hold three-dimensional MR angiography [J].
Hany, TF ;
McKinnon, GC ;
Leung, DA ;
Pfammatter, T ;
Debatin, JF .
JMRI-JOURNAL OF MAGNETIC RESONANCE IMAGING, 1997, 7 (03) :551-556
[5]   Thoracic spiral CT: Delivery of contrast material pushed with injectable saline solution in a power injector [J].
Hopper, KD ;
Mosher, TJ ;
Kasales, CJ ;
TenHave, TR ;
Tully, DA ;
Weaver, JS .
RADIOLOGY, 1997, 205 (01) :269-271
[6]   Contrast-enhanced abdominal MR angiography: Optimization of imaging delay time by automating the detection of contrast material arrival in the aorta [J].
Prince, MR ;
Chenevert, TL ;
Foo, TKF ;
Londy, FJ ;
Ward, JS ;
Maki, JH .
RADIOLOGY, 1997, 203 (01) :109-114
[7]   AN EXPERIMENTAL EVALUATION OF CENTRAL VS PERIPHERAL INJECTION FOR INTRAVENOUS DIGITAL SUBTRACTION ANGIOGRAPHY (IV-DSA) [J].
RUBIN, DL ;
BURBANK, FH ;
BRADLEY, BR ;
BRODY, WR .
INVESTIGATIVE RADIOLOGY, 1984, 19 (01) :30-35