The increasing penetration of renewable sources with power-electronic interfaces in power systems is raising technical problems and the overall efficiency of photovoltaic systems can decrease dramatically. In this context, the optimal layout for the photovoltaic system is required. The most adequate strategy to connect the renewable system to the electrical power grid or to supply the end users must be adopted. The present paper proposes a design layout of a PV plant using a DC bus system to improve the overall energy conversion efficiency. An analysis of steady-state system stability, voltage drop and DC cable conduction losses is conducted. The leakage currents to the ground are investigated through simulations. Experimental results are shown focused on the analysis of optimal layout of photovoltaic systems under particular operating conditions.
引用
收藏
页码:3736 / 3752
页数:17
相关论文
共 26 条
[1]   Power electronics as efficient interface in dispersed power generation systems [J].
Blaabjerg, F ;
Chen, Z ;
Kjaer, SB .
IEEE TRANSACTIONS ON POWER ELECTRONICS, 2004, 19 (05) :1184-1194
[2]   Overview of control and grid synchronization for distributed power generation systems [J].
Blaabjerg, Frede ;
Teodorescu, Remus ;
Liserre, Marco ;
Timbus, Adrian V. .
IEEE TRANSACTIONS ON INDUSTRIAL ELECTRONICS, 2006, 53 (05) :1398-1409
[3]  
Brenna M., 2009, P IEEE BUCH POWERTEC, P1
[4]   LIGHTNING AND SURGE PROTECTION OF SUBSTATIONS [J].
CARPENTER, RB ;
AUER, RL .
IEEE TRANSACTIONS ON INDUSTRY APPLICATIONS, 1995, 31 (01) :162-170
[5]   Accurate and Less-Disturbing Active Antiislanding Method Based on PLL for Grid-Connected Converters [J].
Ciobotaru, Mihai ;
Agelidis, Vassilios G. ;
Teodorescu, Remus ;
Blaabjerg, Frede .
IEEE TRANSACTIONS ON POWER ELECTRONICS, 2010, 25 (06) :1576-1584
[6]   Performance Analysis of a Single-Axis Tracking PV System [J].
Dolara, Alberto ;
Grimaccia, Francesco ;
Leva, Sonia ;
Mussetta, Marco ;
Faranda, Roberto ;
Gualdoni, Moris .
IEEE JOURNAL OF PHOTOVOLTAICS, 2012, 2 (04) :524-531
[7]   An adaptive control for UPS to compensate unbalance and harmonic distortion using a combined capacitor/load current sensing [J].
Escobar, G. ;
Mattavelli, P. ;
Stankovic, A. M. ;
Valdez, Andres A. ;
Leyva-Ramos, Jesus .
IEEE TRANSACTIONS ON INDUSTRIAL ELECTRONICS, 2007, 54 (02) :839-847
[8]  
Faranda R, 2008, IEEE POW ENER SOC GE, P2218
[9]   A Generic Open-Loop Algorithm for Three-Phase Grid Voltage/Current Synchronization With Particular Reference to Phase, Frequency, and Amplitude Estimation [J].
Freijedo, Francisco D. ;
Doval-Gandoy, Jesus ;
Lopez, Oscar ;
Acha, Enrique .
IEEE TRANSACTIONS ON POWER ELECTRONICS, 2009, 24 (1-2) :94-107
[10]   A review of single-phase grid-connected inverters for photovoltaic modules [J].
Kjaer, SB ;
Pedersen, JK ;
Blaabjerg, F .
IEEE TRANSACTIONS ON INDUSTRY APPLICATIONS, 2005, 41 (05) :1292-1306