Molecular Magnetic Resonance Imaging of Deep Vein Thrombosis Using a Fibrin-Targeted Contrast Agent A Feasibility Study

被引:27
作者
Katoh, Marcus [1 ,2 ]
Haage, Patrick [3 ]
Wiethoff, Andrea J. [4 ]
Guenther, Rolf W.
Buecker, Arno [1 ]
Tacke, Josef [5 ]
Spuentrup, Elmar [2 ]
机构
[1] Univ Hosp Saarland, Dept Diagnost & Intervent Radiol, D-66424 Homburg, Germany
[2] RWTH Aachen Univ Hosp, Dept Diagnost Radiol, Aachen, Germany
[3] HELIOS Klin, Dept Diagnost & Intervent Radiol, Wuppertal, Germany
[4] EPLX Pharmaceut, Lexington, MA USA
[5] Klinikum Passau, Dept Diagnost Radiol, Passau, Germany
关键词
molecular MRI; fibrin-specific contrast agent; deep vein thrombosis; interventional radiology; AMPLATZ THROMBECTOMY DEVICE; MECHANICAL THROMBECTOMY; SWINE MODEL; IN-VITRO; CORONARY-THROMBOSIS; PULMONARY-EMBOLISM; ULTRASOUND; THROMBOLYSIS; EXPERIENCE; EP-2104R;
D O I
10.1097/RLI.0b013e318195886d
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: To evaluate the value of a fibrin-specific MR contrast agent (EP-2104R; EPIX Pharmaceuticals) for detection of deep vein thrombosis (DVT) and monitoring of percutaneous intervention for treatment. Materials and Methods: In 6 domestic swine, DVT was induced in an iliac/femoral vein using an occlusion-balloon catheter and subsequent injection of thrombin. The occluded vessels were recanalized by mechanical thrombectomy using a Fogarty catheter and an Arrow rotating thrombectomy device. Magnetic resonance imaging of the pelvis and lung was repeated 4 times (before and after DVT induction, after contrast agent administration, and after intervention) using a 1.5-T whole-body XMR system (ACS-NT, Philips Medical Systems, Best, NL). The visualization of the thrombi and contrast-to-noise ratio (CNR) was assessed. Results: EP-21048 allowed selective visualization of thrombi with accurate determination of the extent of DVT with high contrast (CNR: 65.3 +/- 17.2). After intervention, dislodged thrombus fragments were selectively visualized in the lung (CNR: 27.9 +/- 9.3). Conclusions: Molecular magnetic resonance imaging using fibrin-specific MR contrast agent EP-21048 allowed for selective visualization of DVT and monitoring of percutaneous intervention.
引用
收藏
页码:146 / 150
页数:5
相关论文
共 26 条
[1]  
Belcaro G, 1999, ANGIOLOGY, V50, P707
[2]   Noninvasive in vivo clot dissolution without a thrombolytic drug - Recanalization of thrombosed iliofemoral arteries by transcutaneous ultrasound combined with intravenous infusion of microbubbles [J].
Birnbaum, Y ;
Luo, H ;
Nagai, T ;
Fishbein, MC ;
Peterson, TM ;
Li, SP ;
Kricsfeld, D ;
Porter, TR ;
Siegel, RJ .
CIRCULATION, 1998, 97 (02) :130-134
[3]   In vivo magnetic resonance imaging of coronary thrombosis using a fibrin-binding molecular magnetic resonance contrast agent [J].
Botnar, RM ;
Buecker, A ;
Wiethoff, AJ ;
Parsons, EC ;
Katoh, M ;
Katsimaglis, G ;
Weisskoff, RM ;
Lauffer, RB ;
Graham, PB ;
Gunther, RW ;
Manning, WJ ;
Spuentrup, E .
CIRCULATION, 2004, 110 (11) :1463-1466
[4]   In vivo molecular imaging of acute and subacute thrombosis using a fibrin-binding magnetic resonance imaging contrast agent [J].
Botnar, RM ;
Perez, AS ;
Witte, S ;
Wiethoff, AJ ;
Laredo, J ;
Hamilton, J ;
Quist, W ;
Parsons, EC ;
Vaidya, A ;
Kolodziej, A ;
Barrett, JA ;
Graham, PB ;
Weisskoff, RM ;
Manning, WJ ;
Johnstone, MT .
CIRCULATION, 2004, 109 (16) :2023-2029
[5]   CLINICAL RISKS OF THROMBOLYTIC THERAPY [J].
CALIFF, RM ;
FORTIN, DF ;
TENAGLIA, AN ;
SANE, DC .
AMERICAN JOURNAL OF CARDIOLOGY, 1992, 69 (02) :A12-A20
[6]   Declotting of embolized temporary vena cava filter by ultrasound and the Angiojet -: Comparative experimental in vitro studies [J].
Dick, A ;
Neuerburg, J ;
Schmitz-Rode, T ;
Alliger, H ;
Günther, R .
INVESTIGATIVE RADIOLOGY, 1998, 33 (02) :91-97
[7]   Comparison of the mechanical thrombectomy efficacy of the Amplatz thrombectomy device and the Cragg thrombolytic brush in vitro [J].
Grimm, J ;
Müller-Hülsbeck, S ;
Heller, M .
INVESTIGATIVE RADIOLOGY, 2001, 36 (04) :204-209
[8]   Prototype percutaneous thrombolytic device:: Preclinical testing in subacute inferior vena caval thrombosis in a pig model [J].
Haage, P ;
Tacke, J ;
Bovelander, J ;
Wildberger, JE ;
Klosterhalfen, B ;
Vorwerk, D ;
Günther, RW .
RADIOLOGY, 2001, 220 (01) :135-141
[9]   A porcine deep vein thrombosis model for magnetic resonance-guided monitoring of different thrombectomy procedures [J].
Katoh, Marcus ;
Haage, Patrick ;
Spuentrup, Elmar ;
Guenther, Rolf W. ;
Tacke, Josef .
INVESTIGATIVE RADIOLOGY, 2007, 42 (11) :727-731
[10]   The effects of incomplete breath-holding on 3D MR image quality [J].
Maki, JH ;
Chenevert, TL ;
Prince, MR .
JMRI-JOURNAL OF MAGNETIC RESONANCE IMAGING, 1997, 7 (06) :1132-1139