High-Resolution Ion Cyclotron Mobility Spectrometry

被引:120
作者
Merenbloom, Samuel I. [1 ]
Glaskin, Rebecca S. [1 ]
Henson, Zachary B. [1 ]
Clemmer, David E. [1 ]
机构
[1] Indiana Univ, Dept Chem, Bloomington, IN 47405 USA
基金
美国国家卫生研究院;
关键词
FLIGHT MASS-SPECTROMETRY; GAS-PHASE CONFORMATIONS; ELECTROSPRAY-IONIZATION; STRUCTURAL INFORMATION; PLASMA CHROMATOGRAPHY; IMS-IMS; BIOMOLECULES; CLUSTERS; PEPTIDE; FUNNEL;
D O I
10.1021/ac801880a
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A novel ion mobility spectrometry instrument incorporating a cyclotron geometry drift tube is presented. The drift tube consists of eight regions, four curved drift tubes and four ion funnels. Packets of ions are propagated around the drift tube by changing the drift field at a frequency that is resonant with the ion's drift time through each region. The approach trims each packet of ions as it leaves and enters each new region. An electrostatic gate allows ions to be kept in the drift tube for numerous cycles, increasing the ability to resolve specified ions. We demonstrate the approach by isolating the [M + 2H](2+) or [M + 3H](3+) charge state of substance P as well as individual trisaccharide isomers from a mixture of melezitose and raffinose. Resolving powers in excess of 300 are obtainable with this approach.
引用
收藏
页码:1482 / 1487
页数:6
相关论文
共 45 条
[11]   A tandem ion trap/ion mobility spectrometer [J].
Creaser, CS ;
Benyezzar, M ;
Griffiths, JR ;
Stygall, JW .
ANALYTICAL CHEMISTRY, 2000, 72 (13) :2724-2729
[12]  
DAHL DA, SIMION VERSION 7 0
[13]   High-resolution ion mobility measurements [J].
Dugourd, P ;
Hudgins, RR ;
Clemmer, DE ;
Jarrold, MF .
REVIEW OF SCIENTIFIC INSTRUMENTS, 1997, 68 (02) :1122-1129
[14]   ELECTROSPRAY IONIZATION FOR MASS-SPECTROMETRY OF LARGE BIOMOLECULES [J].
FENN, JB ;
MANN, M ;
MENG, CK ;
WONG, SF ;
WHITEHOUSE, CM .
SCIENCE, 1989, 246 (4926) :64-71
[15]   Coupling high-pressure MALDI with ion mobility/orthogonal time-of flight mass spectrometry [J].
Gillig, KJ ;
Ruotolo, B ;
Stone, EG ;
Russell, DH ;
Fuhrer, K ;
Gonin, M ;
Schultz, AJ .
ANALYTICAL CHEMISTRY, 2000, 72 (17) :3965-3971
[16]   ESI/ion trap/ion mobility/time-of-flight mass spectrometry for rapid and sensitive analysis of biomolecular mixtures [J].
Henderson, SC ;
Valentine, SJ ;
Counterman, AE ;
Clemmer, DE .
ANALYTICAL CHEMISTRY, 1999, 71 (02) :291-301
[17]   Three-dimensional ion mobility TOFMS analysis of electrosprayed biomolecules [J].
Hoaglund, CS ;
Valentine, SJ ;
Sporleder, CR ;
Reilly, JP ;
Clemmer, DE .
ANALYTICAL CHEMISTRY, 1998, 70 (11) :2236-2242
[18]   Anhydrous protein ions [J].
Hoaglund-Hyzer, CS ;
Counterman, AE ;
Clemmer, DE .
CHEMICAL REVIEWS, 1999, 99 (10) :3037-3079
[19]   Helix formation in unsolvated alanine-based peptides: Helical monomers and helical dimers [J].
Hudgins, RR ;
Jarrold, MF .
JOURNAL OF THE AMERICAN CHEMICAL SOCIETY, 1999, 121 (14) :3494-3501
[20]   High resolution ion mobility measurements for gas phase proteins: correlation between solution phase and gas phase conformations [J].
Hudgins, RR ;
Woenckhaus, J ;
Jarrold, MF .
INTERNATIONAL JOURNAL OF MASS SPECTROMETRY, 1997, 165 :497-507