Differences in whole body measurements by DXA-scanning using two Lunar DPX-L machines

被引:18
作者
Lantz, H [1 ]
Samuelson, G
Bratteby, LE
Mallmin, H
Sjöström, L
机构
[1] Sahlgrens Univ Hosp, Dept Med, S-41345 Gothenburg, Sweden
[2] Univ Uppsala Hosp, Dept Med Sci Clin Physiol, Uppsala, Sweden
[3] Univ Uppsala Hosp, Dept Surg Sci Orthopaed, Uppsala, Sweden
关键词
DXA; body fat; lean tissue mass; bone mineral content; between instrument comparisons;
D O I
10.1038/sj.ijo.0800905
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
OBJECTIVE: To compare bone mineral and body composition results of two dual-energy X-ray absorptiometry (DXA) instruments from the same manufacturer. SETTINGS: The Medical departments of Sahlgrenska University Hospital, Goteborg and University Hospital, Uppsala, Sweden. DESIGN: Unique aluminium spine phantoms (Phant A and B) delivered with each DXA machine (DXA-A and DXA-B) were cross-checked on the other machine by using the 'AP spine mode'. Eight adolescents were examined on both instruments within 5 h to ascertain total body variables by using standard, as well as extended, modes of analysis. All these double-examinations were undertaken on two occasions, before and after exchange of a detector on the DXA-B, SUBJECTS: Four males and four females aged 15.4-19.2y with normal body weights, were examined on both occasions. On each occasion, the first examination was performed in Goteborg on four individuals and in Uppsala on four individuals. RESULTS: On the first occasion the phantom measurements resulted in much lower bone mineral density (BMD) values on the DXA-B than on the DXA-A. Later it was detected that a so-called R-value and the corresponding '%-fat' value were out of range on the DXA-B. After exchange of detector, the difference in phantom BMD-values between the two machines had diminished. On the first occasion in vivo BMD values were lowest on the DXA-B (P < 0.01), while on the second occasion they were significantly lower on the DXA-A (P < 0.05). Soft tissue differences were greater after detector exchange and as compared to DXA-A, DXA-B underestimated body fat by 3.5 kg (13.2 vs 9.7 kg, Pt 0.001) and overestimated lean tissue mass by 3.8 kg (47.1 vs 50.9 kg, P < 0.001) on the second occasion. CONCLUSIONS: The differences in results between two apparently identical Lunar DPX-L machines were not acceptable. In multicenter studies, it may be necessary to standardise results of participating machines into results of one machine by means of regression equations obtained by examining subsamples of individuals on one master machine and other participating instruments.
引用
收藏
页码:764 / 770
页数:7
相关论文
共 17 条
[1]   STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT [J].
BLAND, JM ;
ALTMAN, DG .
LANCET, 1986, 1 (8476) :307-310
[2]  
Dahlberg G., 1948, STAT METHODS MED BIO, P122
[3]  
DEQUEKER J, 1993, TECHNOL HEALTH CARE, V1, P127, DOI 10.3233/THC-1993-1202
[4]  
Economos CD, 1996, J BONE MINER RES, V11, P275
[5]   A multi-center comparison of dual energy X-ray absorptiometers: In vivo and in vitro soft tissue measurement [J].
Economos, CD ;
Nelson, ME ;
Fiatarone, MA ;
Dallal, GE ;
Heymsfield, SB ;
Wang, J ;
Yasumara, S ;
Ma, R ;
Vaswani, AN ;
RussellAulet, M ;
Pierson, RN .
EUROPEAN JOURNAL OF CLINICAL NUTRITION, 1997, 51 (05) :312-317
[6]   Cross-calibration of body-composition techniques against dual-energy X-ray absorptiometry in young children [J].
Goran, MI ;
Driscoll, P ;
Johnson, R ;
Nagy, TR ;
Hunter, G .
AMERICAN JOURNAL OF CLINICAL NUTRITION, 1996, 63 (03) :299-305
[7]   Body composition analysis by dual energy X-ray absorptiometry in female diabetics differ between manufacturers [J].
Kistorp, CN ;
Svendsen, OL .
EUROPEAN JOURNAL OF CLINICAL NUTRITION, 1997, 51 (07) :449-454
[8]  
Kullenberg RJ, 1996, ACTA RADIOL, V37, P134
[9]   Whole-body bone mineral measurements in 15-year-old Swedish adolescents [J].
Lötborn, M ;
Bratteby, LE ;
Samuelson, G ;
Ljunghall, S ;
Sjöström, L .
OSTEOPOROSIS INTERNATIONAL, 1999, 9 (02) :106-114
[10]  
*MIN, 1992, REF MAN REL 9