Determination of antisense phosphorothioate oligonucleotides and catabolites in biological fluids and tissue extracts using anion-exchange high-performance liquid chromatography and capillary gel electrophoresis

被引:50
作者
Chen, SH [1 ]
Qian, MX [1 ]
Brennan, JM [1 ]
Gallo, JM [1 ]
机构
[1] FOX CHASE CANC CTR,DEPT MED ONCOL,PHILADELPHIA,PA 19111
来源
JOURNAL OF CHROMATOGRAPHY B | 1997年 / 692卷 / 01期
关键词
phosphorothioates; oligodeoxynucleotides;
D O I
10.1016/S0378-4347(96)00499-9
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Chemically modified phosphorothioate oligodeoxynucleotides (ODNs) have become critical tools for research in the fields of gene expression and experimental therapeutics. Bioanalytical assays were developed that utilized fast anion-exchange high-performance liquid chromatography (HPLC) and capillary gel electrophoresis (CGE) for the determination of 20-mer ODNs in biological fluids (plasma and urine) and tissues. A 20 mer ODN in the antisense orientation directed against DNA methyltransferase (denoted as MT-AS) was studied as the model ODN. The anion-exchange HPLC method employed a short column packed with non-porous polymer support and a ternary gradient elution with 2 M lithium bromide containing 30% formamide. Analysis of the MT-AS is accomplished within 5 min with a detection limit of approximately 3 ng on-column at 267 nm. For plasma and urine, samples were diluted with Nonidet P-40 in 0.9% NaCl and directly injected onto the column, resulting in 100% recovery. For tissue homogenates, a protein kinase K digestion and phenol-chloroform extraction were used, with an average recovery of about 50%. Since the HPLC assay cannot provide one-base separation, biological samples were also processed by an anion-exchange solid-phase extraction and a CGE method to characterize MT-AS and its catabolites of 15-20-mer, species most relevant to biological activity. One base separation, under an electric field of 400 V/cm at room temperature, was achieved for a mixture of 15-20-mer with about 50 pg injected. Assay validation studies revealed that the combined HPLC-CGE methods are accurate, reproducible and specific for the determination of MT-AS and its catabolites in biological fluids and tissue homogenates, and can be used for the pharmacokinetic characterization of MT-AS.
引用
收藏
页码:43 / 51
页数:9
相关论文
共 16 条
[1]   PHARMACOKINETICS, BIODISTRIBUTION, AND STABILITY OF OLIGODEOXYNUCLEOTIDE PHOSPHOROTHIOATES IN MICE [J].
AGRAWAL, S ;
TEMSAMANI, J ;
TANG, JY .
PROCEEDINGS OF THE NATIONAL ACADEMY OF SCIENCES OF THE UNITED STATES OF AMERICA, 1991, 88 (17) :7595-7599
[2]   SEPARATION OF SYNTHETIC PHOSPHOROTHIOATE OLIGODEOXYNUCLEOTIDES FROM THEIR OXYGENATED (PHOSPHODIESTER) DEFECT SPECIES BY STRONG-ANION-EXCHANGE HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY [J].
BERGOT, BJ ;
EGAN, W .
JOURNAL OF CHROMATOGRAPHY, 1992, 599 (1-2) :35-42
[3]   HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHIC ANALYSIS OF PHOSPHOROTHIOATE ANALOGS OF OLIGODEOXYNUCLEOTIDES IN BIOLOGICAL-FLUIDS [J].
BIGELOW, JC ;
CHRIN, LR ;
MATHEWS, LA ;
MCCORMACK, JJ .
JOURNAL OF CHROMATOGRAPHY-BIOMEDICAL APPLICATIONS, 1990, 533 :133-140
[4]   QUANTITATIVE-ANALYSIS OF PHOSPHOROTHIOATE OLIGONUCLEOTIDES IN BIOLOGICAL-FLUIDS USING FAST ANION-EXCHANGE CHROMATOGRAPHY [J].
BOURQUE, AJ ;
COHEN, AS .
JOURNAL OF CHROMATOGRAPHY-BIOMEDICAL APPLICATIONS, 1993, 617 (01) :43-49
[5]   QUANTITATIVE-ANALYSIS OF PHOSPHOROTHIOATE OLIGONUCLEOTIDES IN BIOLOGICAL-FLUIDS USING DIRECT-INJECTION FAST ANION-EXCHANGE CHROMATOGRAPHY AND CAPILLARY GEL-ELECTROPHORESIS [J].
BOURQUE, AJ ;
COHEN, AS .
JOURNAL OF CHROMATOGRAPHY B-BIOMEDICAL APPLICATIONS, 1994, 662 (02) :343-349
[6]  
COHEN AS, 1993, J CHROMATOGR, V638, P293
[7]  
Crooke S. T., 1995, THERAPEUTIC APPL OLI
[8]   HIGH-SPEED SEPARATIONS OF DNA SEQUENCING REACTIONS BY CAPILLARY ELECTROPHORESIS [J].
DROSSMAN, H ;
LUCKEY, JA ;
KOSTICHKA, AJ ;
DCUNHA, J ;
SMITH, LM .
ANALYTICAL CHEMISTRY, 1990, 62 (09) :900-903
[9]  
Hawley P, 1992, Antisense Res Dev, V2, P119
[10]  
HUANG X, 1988, ANAL CHEM, V60, P377