Development of a rapid response biosensor for detection of Salmonella typhimurium

被引:62
作者
Seo, KH
Brackett, RE [1 ]
Hartman, NF
Campbell, DP
机构
[1] Univ Georgia, Ctr Food Safety & Qual Enhancement, Expt Stn, Griffin, GA 30223 USA
[2] Georgia Inst Technol, Environm & Mat Lab, Atlanta, GA 30087 USA
关键词
D O I
10.4315/0362-028X-62.5.431
中图分类号
Q81 [生物工程学(生物技术)]; Q93 [微生物学];
学科分类号
071005 ; 0836 ; 090102 ; 100705 ;
摘要
An integrated optic interferometer for detecting foodborne pathogens was developed. The interferometer is a planar waveguide with two thin antibody-coated channels of immunochemically selective agents that interact with antigen molecules. One channel is coated with antibody to Salmonella as a sample, and the other is coated with human immunoglobulin G as a reference channel by using reductive amination. Salmonella was introduced onto the sensing channels through the flow cell on the channels. Phase shift (pi) generated by refractive index variation, as determined by interfering the perturbed sample channel with an unperturbed reference channel and observing the fringe shift, was used for detection. Salmonella Typhimurium (heat-treated or boiled) was detected by binding to antibody against Salmonella common structural antigen immobilized on a silane-derived sensor surface at concentrations in the range of 1 x 10(5) to 1 x 10(7) CFU/ml. Salmonella (1 x 10(7) CFU/ml) mixed with Escherichia coli (1 x 10(7) CFU/ml) were readily detected without any decrease in sensitivity by the direct assay. Application of a sandwich assay with a second antibody or a gold-conjugated antibody increased the detection limit to 1 x 10(5) CFU/ml within a 10-min reaction time. Various methods for the immobilization of the capture antibody to the biosensor channels were compared. The greatest binding response was observed in a direct reductive amination method with a long reaction period and increased the detection limit of direct binding of Salmonella antigen to 1 x 10(4) CFU/ml. The biosensor was able to detect Salmonella Typhimurium in chicken carcass wash fluid originally inoculated at a level of 20 CFU/ml after 12 h of nonselective enrichment. The planar optic biosensor shows promise as a fast, sensitive, reliable, and economical means of detecting food pathogens in the future.
引用
收藏
页码:431 / 437
页数:7
相关论文
共 18 条
[1]  
AKERSTROM B, 1986, J BIOL CHEM, V261, P240
[2]   EXPERIMENTAL ENZYME-LINKED AMPEROMETRIC IMMUNOSENSORS FOR THE DETECTION OF SALMONELLAS IN FOODS [J].
BROOKS, JL ;
MIRHABIBOLLAHI, B ;
KROLL, RG .
JOURNAL OF APPLIED BACTERIOLOGY, 1992, 73 (03) :189-196
[3]   SAMPLING OF BROILER CARCASSES FOR SALMONELLA WITH LOW VOLUME WATER RINSE [J].
COX, NA ;
THOMSON, JE ;
BAILEY, JS .
POULTRY SCIENCE, 1981, 60 (04) :768-770
[4]  
DOYLE MP, 1993, NUTR REV, V51, P346
[5]   Enzyme-linked immunomagnetic electrochemical detection of Salmonella typhimurium [J].
Gehring, AG ;
Crawford, CG ;
Mazenko, RS ;
VanHouten, LJ ;
Brewster, JD .
JOURNAL OF IMMUNOLOGICAL METHODS, 1996, 195 (1-2) :15-25
[6]  
HERMANSON GT, 1992, IMMOBILIZED AFFINITY, P51
[7]   A NOVEL LIPOSOME-BASED ELECTROCHEMICAL BIOSENSOR FOR THE DETECTION OF HEMOLYTIC MICROORGANISMS [J].
KIM, HJ ;
BENNETTO, HP ;
HALABLAB, MA .
BIOTECHNOLOGY TECHNIQUES, 1995, 9 (06) :389-394
[8]   PREPARATION OF IMMOBILIZED ENZYME WITH HIGH-ACTIVITY USING AFFINITY TAG BASED ON PROTEIN-A AND PROTEIN-G [J].
KONDO, A ;
TESHIMA, T .
BIOTECHNOLOGY AND BIOENGINEERING, 1995, 46 (05) :421-428
[9]   A quartz crystal microbalance displacement assay for Listeria monocytogenes [J].
Minunni, M ;
Mascini, M ;
Carter, RM ;
Jacobs, MB ;
Lubrano, GJ ;
Guilbault, GG .
ANALYTICA CHIMICA ACTA, 1996, 325 (03) :169-174
[10]   DEVELOPMENT OF A PIEZOELECTRIC IMMUNOSENSOR FOR THE DETECTION OF SALMONELLA-TYPHIMURIUM [J].
PRUSAKSOCHACZEWSKI, E ;
LUONG, JHT ;
GUILBAULT, GG .
ENZYME AND MICROBIAL TECHNOLOGY, 1990, 12 (03) :173-177