A capillary electrophoresis chip with hydrodynamic sample injection for measurements from a continuous sample flow

被引:17
作者
Büttgenbach, S [1 ]
Wilke, R [1 ]
机构
[1] Tech Univ Braunschweig, Inst Microtechnol, D-38106 Braunschweig, Germany
关键词
microchip capillary electrophoresis; on-line monitoring; poly(dimethylsiloxane); hydrodynamic sample injection; ELECTROCHEMICAL DETECTION; MICROCHIP; INTERFACE; SYSTEMS;
D O I
10.1007/s00216-005-3346-6
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
A microchip-based capillary electrophoresis device supported by a microfluidic network made of poly(dimethylsiloxane), used for measuring target analytes from a continuous sample flow, is presented. The microsystem was fabricated by means of replica molding in combination with standard microfabrication technologies, resulting in microfluidic components and an electrochemical detector. A new hydrodynamic sample injection procedure is introduced, and the maximum number of consecutive measurements that can be made with a poly(dimethylsiloxane) capillary electrophoresis chip with amperometric detection is investigated with respect to reproducibility. The device features a high degree of functional integration, so the benefits associated with miniaturized analysis systems apply to it.
引用
收藏
页码:733 / 737
页数:5
相关论文
共 20 条
[1]  
Attiya S, 2001, ELECTROPHORESIS, V22, P318, DOI 10.1002/1522-2683(200101)22:2<318::AID-ELPS318>3.0.CO
[2]  
2-G
[3]   Micro total analysis systems. 2. Analytical standard operations and applications [J].
Auroux, PA ;
Iossifidis, D ;
Reyes, DR ;
Manz, A .
ANALYTICAL CHEMISTRY, 2002, 74 (12) :2637-2652
[4]  
Bruin GJM, 2000, ELECTROPHORESIS, V21, P3931, DOI 10.1002/1522-2683(200012)21:18<3931::AID-ELPS3931>3.0.CO
[5]  
2-M
[6]   Electrophoretic separation schemes in ultrathin channels with capillary sample introduction [J].
Bullard, KM ;
Gavin, PF ;
Ewing, AG .
TRAC-TRENDS IN ANALYTICAL CHEMISTRY, 1998, 17 (07) :401-410
[7]   A high-throughput continuous sample introduction interface for microfluidic chip-based capillary electrophoresis systems [J].
Fang, Q ;
Xu, GM ;
Fang, ZL .
ANALYTICAL CHEMISTRY, 2002, 74 (06) :1223-1231
[8]   Effect of analyte adsorption on the electroosmotic flow in microfluidic channels [J].
Ghosal, S .
ANALYTICAL CHEMISTRY, 2002, 74 (04) :771-775
[9]   Poly(dimethylsiloxane) microchip capillary electrophoresis with electrochemical detection for rapid measurement of acetaminophen and its hydrolysate [J].
He, FY ;
Liu, AL ;
Xia, XH .
ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2004, 379 (7-8) :1062-1067
[10]   Red diode laser induced fluorescence detection with a confocal microscope on a microchip for capillary electrophoresis [J].
Jiang, GF ;
Attiya, S ;
Ocvirk, G ;
Lee, WE ;
Harrison, DJ .
BIOSENSORS & BIOELECTRONICS, 2000, 14 (10-11) :861-869