The microdroplet test: experimental and finite element analysis of the dependance of failure mode on droplet shape

被引:29
作者
Hodzic, A [1 ]
Kalyanasundaram, S [1 ]
Lowe, A [1 ]
Stachurski, ZH [1 ]
机构
[1] Australian Natl Univ, Fac Engn & Informat Technol, Dept Engn, Canberra, ACT 0200, Australia
关键词
microdroplet; finite element analysis; composite interface; crack propagation; silane coupling agent;
D O I
10.1163/156855498X00379
中图分类号
TB33 [复合材料];
学科分类号
摘要
The microdroplet technique is usually designed as a fibre embedded in a drop of resin and subsequently pulled out while the drop is being supported by two knife edges, resulting in either debonding of the droplets from the fibres, or breakage of the fibres before debonding can occur. In this study, the microdroplet technique was performed using a platinum ring with a 40 mu m hole instead of the usual two knife edges, giving an axisymmetric geometry, load and stress distribution. Glass/phenolic and glass/polyester composite systems were tested experimentally and subsequent finite element modelling studies were performed to assess the variation of droplet size, and contact angle between the droplet and fibre, It was found that contact angle is of major influence in the proposed failure model. This study characterizes the influence of the contact angle between the droplet and the fibre on the subsequent stress distribution in the microdroplet specimen.
引用
收藏
页码:375 / 389
页数:15
相关论文
共 15 条
[1]   ANALYSIS OF THE SINGLE-FIBER PULL-OUT TEST BY MEANS OF RAMAN-SPECTROSCOPY .2. MICROMECHANICS OF DEFORMATION FOR AN ARAMID/EPOXY SYSTEM [J].
BANNISTER, DJ ;
ANDREWS, MC ;
CERVENKA, AJ ;
YOUNG, RJ .
COMPOSITES SCIENCE AND TECHNOLOGY, 1995, 53 (04) :411-421
[2]   THE EFFECT OF MICROVISE GAP WIDTH ON MICROBOND PULL-OUT TEST-RESULTS [J].
CHOU, CT ;
GAUR, U ;
MILLER, B .
COMPOSITES SCIENCE AND TECHNOLOGY, 1994, 51 (01) :111-116
[3]  
DRZAL LT, 1991, ENG MATERIALS HDB, V3, P391
[4]   THE THROMBOGENICITY OF PROTHROMBIN COMPLEX CONCENTRATES AND FACTOR-IX CONCENTRATES IN-VIVO [J].
HAMPTON, KK .
HAEMOPHILIA, 1995, 1 :26-27
[5]   SIMULATING THE MICROBOND TECHNIQUE WITH MACRODROPLETS [J].
HANN, LP ;
HIRT, DE .
COMPOSITES SCIENCE AND TECHNOLOGY, 1995, 54 (04) :423-430
[6]   Improvements to the microdroplet single fibre composite test [J].
Mak, M ;
Lowe, A ;
Jar, B ;
Stachurski, Z ;
Fitzgerald, J .
JOURNAL OF MATERIALS SCIENCE LETTERS, 1998, 17 (08) :645-647
[7]  
MAK MA, SUMMER SCH RES REP 1
[8]   Interfacial crack propagation arising in single-fiber pull-out tests [J].
Marotzke, C ;
Qiao, L .
COMPOSITES SCIENCE AND TECHNOLOGY, 1997, 57 (08) :887-897
[9]   ANALYSIS OF THE SINGLE-FIBER PULL-OUT TEST BY THE USE OF RAMAN-SPECTROSCOPY .1. PULL-OUT OF ARAMID FIBERS FROM AN EPOXY-RESIN [J].
PATRIKIS, AK ;
ANDREWS, MC ;
YOUNG, RJ .
COMPOSITES SCIENCE AND TECHNOLOGY, 1994, 52 (03) :387-396
[10]   Why interface testing by single-fibre methods can be misleading [J].
Piggott, MR .
COMPOSITES SCIENCE AND TECHNOLOGY, 1997, 57 (08) :965-974