摘要
OBJECTIVE. The objective of our study was to validate the feasibility of the synergistic use of cardiac MR and CT data sets for ventricular motility analysis and to correlate measurement variability with underlying heart rate. SUBJECTS AND METHODS. Twenty patients underwent concurrent ECG-gated MDCT and MRI for evaluation of ventricular motility, expressed as ventricular wall thickening and motion. Initially, individual measurement repetition series were analyzed by determining intraobserver variability and detecting intraobserver bias related to heart rates. Subsequently, absolute measurement differences of CT or MR data were statistically evaluated. Finally, absolute measurement differences were correlated with underlying heart rates by curve estimation regression. RESULTS. Analysis of measurement reproducibility proved that data variability was dependent on only the anatomic localization of the analyzed ventricular segment, not on the imaging technique used or underlying heart rate, in normofrequent patients. Comparing MR and CT image data sets, no statistically significant differences were identified when ventricular motility was evaluated based on data sets of either imaging technique in normofrequent patients. Tachycardic frequencies, above 100 beats per minute, led to exponential error propagation due to insufficient temporal resolution of the current CT technology. CONCLUSION. This study proved that cardiac motility assessment based on ECG-gated CT and MR data sets resulted in comparable ventricular function results for normofrequent patients; however, the high spatial resolution of cardiac MDCT cannot compensate for the lack of temporal resolution in patients with tachycardia, thus emphasizing the necessity of reporting ventricular motility analysis results in combination with heart rate to allow consideration of this possible cause for measurement variation.
引用
收藏
页码:S379 / S386
页数:8
相关论文
共 32 条
[1]   METHODS AND THEORY OF RELIABILITY [J].
BARTKO, JJ ;
CARPENTER, WT .
JOURNAL OF NERVOUS AND MENTAL DISEASE, 1976, 163 (05) :307-317
[2]   Functional cardiac CT and MR - Effects of heart rate and software applications on measurement validity [J].
Boll, DT ;
Gilkeson, RC ;
Merkle, EM ;
Fleiter, TR ;
Duerk, JL ;
Lewin, JS .
JOURNAL OF THORACIC IMAGING, 2005, 20 (01) :10-16
[3]   Standardized myocardial segmentation and nomenclature for tomographic imaging of the heart - A statement for healthcare professionals from the Cardiac Imaging Committee of the Council on Clinical Cardiology of the American Heart Association [J].
Cerqueira, MD ;
Weissman, NJ ;
Dilsizian, V ;
Jacobs, AK ;
Kaul, S ;
Laskey, WK ;
Pennell, DJ ;
Rumberger, JA ;
Ryan, T ;
Verani, MS .
CIRCULATION, 2002, 105 (04) :539-542
[4]  
Didier Dominique, 2003, Magn Reson Imaging Clin N Am, V11, P115, DOI 10.1016/S1064-9689(02)00024-7
[5]   Multi-slice CT (MSCT) in cardiac function imaging: Threshold-value-supported 3D volume reconstructions to determine the left ventricular ejection fraction in comparison to MRI [J].
Ehrhard, K ;
Oberholzer, K ;
Gast, K ;
Mildenberger, P ;
Kreitner, KF ;
Thelen, M .
ROFO-FORTSCHRITTE AUF DEM GEBIET DER RONTGENSTRAHLEN UND DER BILDGEBENDEN VERFAHREN, 2002, 174 (12) :1566-1569
[6]   New technical developments in multislice CT, part 2: Sub-millimeter 16-slice scanning and increased gantry rotation speed for cardiac Imaging [J].
Flohr, T ;
Bruder, H ;
Stierstorfer, K ;
Simon, J ;
Schaller, S ;
Ohnesorge, B .
ROFO-FORTSCHRITTE AUF DEM GEBIET DER RONTGENSTRAHLEN UND DER BILDGEBENDEN VERFAHREN, 2002, 174 (08) :1022-1027
[7]   Regional right ventricular endocardial motion in normal hearts and in hearts with left ventricular aneurysm: a three dimensional study [J].
Guez, DH ;
Sideman, S ;
Beyar, R .
INTERNATIONAL JOURNAL OF CARDIAC IMAGING, 1997, 13 (04) :281-291
[8]   Evaluation of left ventricular dysfunction using multiphasic reconstructions of coronary multi-slice computed tomography data in patients with chronic ischemic heart disease: validation against cine magnetic resonance imaging [J].
Halliburton, SS ;
Petersilka, M ;
Schvartzman, PR ;
Obuchowski, N ;
White, RD .
INTERNATIONAL JOURNAL OF CARDIOVASCULAR IMAGING, 2003, 19 (01) :73-83
[9]   Coronary artery calcium: Accuracy and reproducibility of measurements with multi-detector row CT - Assessment of effects of different thresholds and quantification methods [J].
Hong, C ;
Bae, KT ;
Pilgram, TK .
RADIOLOGY, 2003, 227 (03) :795-801
[10]   Using ECG-gated multicletector CT to evaluate global left ventricular myocardial function in patients with coronary artery disease [J].
Juergens, KU ;
Grude, M ;
Fallenberg, EM ;
Opitz, C ;
Wichter, T ;
Heindel, W ;
Fischbach, R .
AMERICAN JOURNAL OF ROENTGENOLOGY, 2002, 179 (06) :1545-1550