Conductimetric immunosensor based on poly( 3,4-ethylenedioxythiophene)

被引:50
作者
Kanungo, M [1 ]
Srivastava, DN [1 ]
Kumar, A [1 ]
Contractor, AQ [1 ]
机构
[1] Indian Inst Technol, Dept Chem, Bombay 400076, Mumbai, India
关键词
D O I
10.1039/b111728a
中图分类号
O6 [化学];
学科分类号
0703 ;
摘要
A conductimetric reagentless immunosensor using the biospecific binding pair of goat antirabbit IgG and rabbit IgG has been designed and fabricated using poly (3,4-ethylenedioxythiophene) as the immobilization matrix-cumtransducer.
引用
收藏
页码:680 / 681
页数:2
相关论文
共 14 条
[11]   A glucose biosensor based on modified-enzyme incorporated within electropolymerised poly(3,4-ethylenedioxythiophene) (PEDT) films [J].
Piro, B ;
Dang, LA ;
Pham, MC ;
Fabiano, S ;
Tran-Minh, C .
JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 2001, 512 (1-2) :101-109
[12]   Polyaniline label-based conductometric sensor for IgG detection [J].
Sergeyeva, TA ;
Lavrik, NV ;
Piletsky, SA ;
Rachkov, AE ;
Elskaya, AV .
SENSORS AND ACTUATORS B-CHEMICAL, 1996, 34 (1-3) :283-288
[13]   A study of polyaniline microtubules: Toward superior transducing abilities [J].
Sukeerthi, S ;
Contractor, AQ .
CHEMISTRY OF MATERIALS, 1998, 10 (09) :2412-2418
[14]  
YAMAMOTO H, 1995, J ELECTROANAL CHEM, V297, P163