A glucose biosensor based on modified-enzyme incorporated within electropolymerised poly(3,4-ethylenedioxythiophene) (PEDT) films

被引:74
作者
Piro, B
Dang, LA
Pham, MC
Fabiano, S
Tran-Minh, C
机构
[1] Univ Paris 07, Inst Topol & Dynam Syst, CNRS, URA 34, F-75005 Paris, France
[2] Ecole Natl Super Mines, Ctr SPIN, F-42023 St Etienne Du Rouvray 2, France
关键词
biosensors; covalent immobilisation; conducting polymers; glucose; electrochemical quartz microbalance;
D O I
10.1016/S0022-0728(01)00595-2
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
We have constructed and characterised a glucose sensor using glucose oxidase (GOD) covalently attached to carboxylic acid polyethyleneglycol (PEG), called (PEG-GOD). This modified enzyme was entrapped afterwards within poly(3,4-ethylenedioxythiophene) (PEDT) films electrogenerated on glassy carbon (GC) electrodes. The composite (PEG-GOD/PEDT) film is more porous than the film without enzyme (PEDT + PEG). Data from electrochemical quartz microbalance (ECQM) and pH-stat experiments indicate a good relative activity of the modified enzyme, ca. 12-15%. Amperometric measurements, using ferrocenemethanol as the redox mediator, confirms that the modified enzyme is catalytically active. The effect of film thickness was also investigated. The sensitivities were quite similar for modified-GOD electrodes (ca. 3 mA cm (-2) M (-1)) and unmodified-GOD electrodes (ca. 2.7 mA cm -(2) M (-1)) but a better stability was obtained with modified PEG-GOD electrodes. (C) 2001 Elsevier Science B.V. All rights reserved.
引用
收藏
页码:101 / 109
页数:9
相关论文
共 41 条
[1]   IMMOBILIZATION OF GLUCOSE-OXIDASE IN THIN POLYPYRROLE FILMS - INFLUENCE OF POLYMERIZATION CONDITIONS AND FILM THICKNESS ON THE ACTIVITY AND STABILITY OF THE IMMOBILIZED ENZYME [J].
ALMEIDA, NF ;
BECKMAN, EJ ;
ATAAI, MM .
BIOTECHNOLOGY AND BIOENGINEERING, 1993, 42 (09) :1037-1045
[2]   A scanning force microscopy study of poly(phenol) films containing immobilized glucose oxidase [J].
Arrigan, DWM ;
Bartlett, PN .
BIOSENSORS & BIOELECTRONICS, 1998, 13 (3-4) :293-304
[3]   ELECTROCHEMICAL IMMOBILIZATION OF ENZYMES .1. THEORY [J].
BARTLETT, PN ;
WHITAKER, RG .
JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 1987, 224 (1-2) :27-35
[4]   ELECTROCHEMICAL IMMOBILIZATION OF ENZYMES .3. IMMOBILIZATION OF GLUCOSE-OXIDASE IN THIN-FILMS OF ELECTROCHEMICALLY POLYMERIZED PHENOLS [J].
BARTLETT, PN ;
TEBBUTT, P ;
TYRRELL, CH .
ANALYTICAL CHEMISTRY, 1992, 64 (02) :138-142
[5]   ELECTROCHEMICAL IMMOBILIZATION OF ENZYMES .2. GLUCOSE-OXIDASE IMMOBILIZED IN POLY-N-METHYLPYRROLE [J].
BARTLETT, PN ;
WHITAKER, RG .
JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 1987, 224 (1-2) :37-48
[6]   ELECTROCHEMICAL IMMOBILIZATION OF ENZYMES .5. MICROELECTRODES FOR THE DETECTION OF GLUCOSE BASED ON GLUCOSE-OXIDASE IMMOBILIZED IN A POLY(PHENOL) FILM [J].
BARTLETT, PN ;
CARUANA, DJ .
ANALYST, 1992, 117 (08) :1287-1292
[7]  
BARTLETT PN, 1993, J ELECTROANAL CHEM, V362, P1
[8]   ELECTROCHEMISTRY OF THE POLYPYRROLE GLUCOSE-OXIDASE ELECTRODE [J].
BELANGER, D ;
NADREAU, J ;
FORTIER, G .
JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 1989, 274 (1-2) :143-155
[9]   ELECTROCHEMICAL IMMOBILIZATION OF GLUCOSE-OXIDASE IN POLY(AMPHIPHILIC PYRROLE) FILMS AND ITS APPLICATION TO THE PREPARATION OF AN AMPEROMETRIC GLUCOSE SENSOR [J].
COCHEGUERENTE, L ;
DERONZIER, A ;
MAILLEY, P ;
MOUTET, JC .
ANALYTICA CHIMICA ACTA, 1994, 289 (02) :143-153
[10]   Poly(pyrrole-biotin): a new polymer for biomolecule grafting on electrode surfaces [J].
Cosnier, S ;
Lepellec, A .
ELECTROCHIMICA ACTA, 1999, 44 (11) :1833-1836