Novel Ion Traps Using Planar Resistive Electrodes: Implications for Miniaturized Mass Analyzers

被引:44
作者
Austin, Daniel E. [1 ]
Peng, Ying [1 ]
Hansen, Brett J. [2 ]
Miller, Ivan W. [1 ]
Rockwood, Alan L. [3 ,4 ]
Hawkins, Aaron R. [2 ]
Tolley, Samuel E. [5 ]
机构
[1] Brigham Young Univ, Dept Chem & Biochem, Provo, UT 84602 USA
[2] Brigham Young Univ, Dept Elect & Comp Engn, Provo, UT 84602 USA
[3] Univ Utah, Sch Med, Dept Pathol, Salt Lake City, UT USA
[4] ARUP Labs, Salt Lake City, UT USA
[5] Tor Technol Inc, Amer Fork, UT USA
关键词
D O I
10.1016/j.jasms.2008.03.019
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
In radiofrequency ion traps, electric fields are produced by applying time-varying potentials between machined metal electrodes. The electrode shape constitutes a boundary condition and defines the field shape. This paper presents a new approach to making ion traps in which the electrodes consist of two ceramic discs, the facing Surfaces of which are lithographically imprinted with sets of concentric metal rings and overlaid with a resistive material. A radial potential function can be applied to the resistive material such that the potential between the plates is quadrupolar, and ions are trapped between the plates. The electric field is independent of geometry and can be optimized electronically. The trap can produce any trapping field geometry, including both a toroidal trapping geometry and the traditional Paul-trap field. Dimensionally smaller ion trajectories, as would be produced in a miniaturized ion trap, can be achieved by increasing the potential gradient on the resistive material and operating the trap at higher frequency, rather than by making any physical changes to the trap or the electrodes. Obstacles to miniaturization of ion traps, such as fabrication tolerances, Surface smoothness, electrode alignment, limited access for ionization or ion injection, and small trapping volume are addressed using this design. (J Am Soc Mass Spectrom 2008, 19, 1435-1441) (C) 2008 American Society for Mass Spectrometry
引用
收藏
页码:1435 / 1441
页数:7
相关论文
共 36 条
[1]   Halo ion trap mass spectrometer [J].
Austin, Daniel E. ;
Wang, Miao ;
Tolley, Samuel E. ;
Maas, Jeffrey D. ;
Hawkins, Aaron R. ;
Rockwood, Alan L. ;
Tolley, H. Dennis ;
Lee, Edgar D. ;
Lee, Milton L. .
ANALYTICAL CHEMISTRY, 2007, 79 (07) :2927-2932
[2]   Simulations of ion trapping in a micrometer-sized cylindrical ion trap [J].
Austin, DE ;
Cruz, D ;
Blain, MG .
JOURNAL OF THE AMERICAN SOCIETY FOR MASS SPECTROMETRY, 2006, 17 (03) :430-441
[3]   Cylindrical ion trap array with mass selection by variation in trap dimensions [J].
Badman, ER ;
Cooks, RG .
ANALYTICAL CHEMISTRY, 2000, 72 (20) :5079-5086
[4]  
Badman ER, 2000, J MASS SPECTROM, V35, P659, DOI 10.1002/1096-9888(200006)35:6<659::AID-JMS5>3.0.CO
[5]  
2-V
[6]   A parallel miniature cylindrical ion trap array [J].
Badman, ER ;
Cooks, RG .
ANALYTICAL CHEMISTRY, 2000, 72 (14) :3291-3297
[7]   Towards the hand-held mass spectrometer: design considerations, simulation, and fabrication of micrometer-scaled cylindrical ion traps [J].
Blain, MG ;
Riter, LS ;
Cruz, D ;
Austin, DE ;
Wu, GX ;
Plass, WR ;
Cooks, RG .
INTERNATIONAL JOURNAL OF MASS SPECTROMETRY, 2004, 236 (1-3) :91-104
[8]  
BLANC JCY, 2003, PROTEOMICS, V3, P859
[9]   Fabrication and testing of a miniature cylindrical ion trap mass spectrometer constructed from low temperature co-fired ceramics [J].
Chaudhary, A ;
van Amerom, FHW ;
Short, RT ;
Bhansali, S .
INTERNATIONAL JOURNAL OF MASS SPECTROMETRY, 2006, 251 (01) :32-39
[10]   Design, microfabrication, and analysis of micrometer-sized cylindrical ion trap arrays [J].
Cruz, D. ;
Chang, J. P. ;
Fico, M. ;
Guymon, A. J. ;
Austin, D. E. ;
Blain, M. G. .
REVIEW OF SCIENTIFIC INSTRUMENTS, 2007, 78 (01)