Scanning beyond anatomic limits of the thorax in chest CT: Findings, radiation dose, and automatic tube current modulation

被引:58
作者
Campbell, J
Kalra, MK
Rizzo, S
Maher, MM
Shepard, JA
机构
[1] Massachusetts Gen Hosp, Dept Radiol, Boston, MA 02114 USA
[2] Natl Univ Ireland Univ Coll Cork, Dept Radiol, Cork, Ireland
关键词
D O I
10.2214/AJR.04.1512
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
OBJECTIVE. Our objective was to determine additional radiation dose associated with scanning beyond the anatomic limits of the thorax in chest CT protocol and to assess the effect of z-axis modulation on the additional radiation dose associated with the scanning protocol. MATERIALS AND METHODS. "Extra" images for routine chest CT were defined as those above lung apices (supraapical) and those caudal to the lowermost portion of lung parenchyma (infrapulmonary), including images obtained beyond the adrenal glands (infraadrenal). One hundred and forty-eight consecutive chest CT examinations (70 men, 78 women; age range, 15-90 years) performed September 13-25, 2003, were reviewed to determine the number of supraapical, infrapulmonary, and infraadrenal extra images. All examinations were performed using z-axis modulation (n = 70) or fixed tube current (it = 78). The CT dose index volume and dose-length product (DLP) values for the extra images were calculated. Two radiologists reviewed these extra images for pathologic findings. Student's t test was used to perform the statistical analysis. RESULTS. One hundred forty-four (97%) examinations had supraapical extra images and 145 (98%) had infrapulmonary extra images. A total of 31 additional findings were observed in extra images. Most clinically important findings were identified in patients with a history of malignancy. With z-axis modulation, the mean DLP for supraapical and infrapulmonary extra images was 39.98 mGy-cm and 132.59 mGy-cm, respectively. With fixed tube current, the mean DLP for supraapical and infrapulmonary extra images was 30.31 mGy-cm and 95.91 mGy-cm, respectively. CONCLUSION. A substantial number of extra images are acquired during chest CT that do not add clinically important information in patients with nonmalignant indications. The use of Z-axis modulation increased radiation dose for the extra images.
引用
收藏
页码:1525 / 1530
页数:6
相关论文
共 15 条
[1]  
ALLARD P, 1990, CANCER, V66, P457, DOI 10.1002/1097-0142(19900801)66:3<457::AID-CNCR2820660310>3.0.CO
[2]  
2-R
[3]  
*GEN EL MED SYST, 2003, LIGHTSP 4 X TECHN RE
[4]   Dose reduction in CT examination of children by an attenuation-based on-line modulation of tube current (CARE Dose) [J].
Greess, H ;
Nömayr, A ;
Wolf, H ;
Baum, U ;
Lell, M ;
Böwing, B ;
Kalender, W ;
Bautz, WA .
EUROPEAN RADIOLOGY, 2002, 12 (06) :1571-1576
[5]   Dose reduction in computed tomography by attenuation-based on-line modulation of tube current: evaluation of six anatomical regions [J].
Greess, H ;
Wolf, H ;
Baum, U ;
Lell, M ;
Pirkl, M ;
Kalender, W ;
Bautz, WA .
EUROPEAN RADIOLOGY, 2000, 10 (02) :391-394
[6]  
ICRP, 2000, ICRP Publication 87, Annals of the ICRP, V30, P7
[7]   Techniques and applications of automatic tube current modulation for CT [J].
Kalra, MK ;
Maher, MM ;
Toth, TL ;
Schmidt, B ;
Westerman, BL ;
Morgan, HT ;
Saini, S .
RADIOLOGY, 2004, 233 (03) :649-657
[8]   Strategies for CT radiation dose optimization [J].
Kalra, MK ;
Maher, MM ;
Toth, TL ;
Hamberg, LM ;
Blake, MA ;
Shephard, JA ;
Saini, S .
RADIOLOGY, 2004, 230 (03) :619-628
[9]   Can noise reduction filters improve low-radiation-dose chest CT images? Pilot study [J].
Kalra, MK ;
Wittram, C ;
Maher, MM ;
Sharma, A ;
Avinash, GB ;
Karau, K ;
Toth, TL ;
Halpern, E ;
Saini, S ;
Shepard, JA .
RADIOLOGY, 2003, 228 (01) :257-264
[10]   Clinical comparison of standard-dose and 50% reduced-dose abdominal CT: Effect on image quality [J].
Kalra, MK ;
Prasad, S ;
Saini, S ;
Blake, MA ;
Varghese, J ;
Halpern, EF ;
Thrall, JH .
AMERICAN JOURNAL OF ROENTGENOLOGY, 2002, 179 (05) :1101-1106