Submillimeter three-dimensional coronary MR angiography with real-time navigator correction: Comparison of navigator locations

被引:182
作者
Stuber, M
Botnar, RM
Danias, PG
Kissinger, KV
Manning, WJ
机构
[1] Beth Israel Deaconess Med Ctr, Div Cardiovasc, Boston, MA 02215 USA
[2] Harvard Univ, Sch Med, Boston, MA 02215 USA
[3] Philips Med Syst, Best, Netherlands
关键词
coronary vessels; MR; heart; magnetic resonance (MR); motion correction; magnetic resonance (MR) vascular studies;
D O I
10.1148/radiology.212.2.r99au50579
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Three-dimensional free-breathing coronary magnetic resonance angiography was performed in eight healthy volunteers with use of real-time navigator technology. Images acquired with the navigator localized at the right hemidiaphragm and at the left ventricle were objectively compared. The diaphragmatic navigator was found to be superior for vessel delineation of middle to distal portions of the coronary arteries.
引用
收藏
页码:579 / 587
页数:9
相关论文
共 47 条
[1]   CORONARY-ARTERY IMAGING AT 0.5 T USING SEGMENTED 3D ECHO-PLANAR IMAGING [J].
BORNERT, P ;
JENSEN, D .
MAGNETIC RESONANCE IN MEDICINE, 1995, 34 (06) :779-785
[2]  
BOTNAR RM, 1998, P 6 M INT SOC MAGN R, P23
[3]   CORONARY ANGIOGRAPHY WITH MAGNETIZATION-PREPARED T-2 CONTRAST [J].
BRITTAIN, JH ;
HU, BS ;
WRIGHT, GA ;
MEYER, CH ;
MACOVSKI, A ;
NISHIMURA, DG .
MAGNETIC RESONANCE IN MEDICINE, 1995, 33 (05) :689-696
[4]   Three-dimensional flow-independent peripheral angiography [J].
Brittain, JH ;
Olcott, EW ;
Szuba, A ;
Gold, GE ;
Wright, GA ;
Irarrazaval, P ;
Nishimura, DG .
MAGNETIC RESONANCE IN MEDICINE, 1997, 38 (03) :343-354
[5]   FAST MR CARDIAC PROFILING WITH 2-DIMENSIONAL SELECTIVE PULSES [J].
CLINE, HE ;
HARDY, CJ ;
PEARLMAN, JD .
MAGNETIC RESONANCE IN MEDICINE, 1991, 17 (02) :390-401
[6]   Prospective navigator correction of image position for coronary MR angiography [J].
Danias, PG ;
McConnell, MV ;
Khasgiwala, VC ;
Chuang, ML ;
Edelman, RR ;
Manning, WJ .
RADIOLOGY, 1997, 203 (03) :733-736
[7]  
DANIAS PG, 1998, P 6 M INT SOC MAGN R, P721
[8]   FAST ALGORITHMS FOR LOW-LEVEL VISION [J].
DERICHE, R .
IEEE TRANSACTIONS ON PATTERN ANALYSIS AND MACHINE INTELLIGENCE, 1990, 12 (01) :78-87
[9]   CORONARY-ARTERY IMAGING IN MULTIPLE 1-SEC BREATH HOLDS [J].
DOYLE, M ;
SCHEIDEGGER, MB ;
DEGRAAF, RG ;
VERMEULEN, J ;
POHOST, GM .
MAGNETIC RESONANCE IMAGING, 1993, 11 (01) :3-6
[10]   CORONARY-ARTERIES - BREATH-HOLD MR ANGIOGRAPHY [J].
EDELMAN, RR ;
MANNING, WJ ;
BURSTEIN, D ;
PAULIN, S .
RADIOLOGY, 1991, 181 (03) :641-643