Soft X-ray imaging using CR-39 plastics with AFM readout

被引:23
作者
Amemiya, K
Takahashi, H
Nakazawa, M
Shimizu, H
Majima, T
Nakagawa, Y
Yasuda, N
Yamamoto, M
Kageji, T
Nakaichi, M
Hasegawa, T
Kobayashi, T
Sakurai, Y
Ogura, K
机构
[1] Univ Tokyo, Dept Quantum Engn & Syst Sci, Bunkyo Ku, Tokyo 1138656, Japan
[2] Univ Tokyo, Ctr Engn, Tokyo 1138656, Japan
[3] Kagawa Univ, Dept Reliabil Based Informat Syst Engn, Kagawa, Japan
[4] Natl Inst Adv Ind Sci & Technol, Photon Res Inst, Ibaraki, Japan
[5] Natl Kagawa Childrens Hosp, Dept Neurosurg, Kagawa, Japan
[6] Natl Inst Radiol Sci, Res Ctr Radiat Safety, Chiba 260, Japan
[7] Univ Tokushima, Dept Neurol Surg, Tokushima 770, Japan
[8] Yamaguchi Univ, Dept Vet Sci, Yamaguchi, Japan
[9] Kyoto Univ, Inst Res Reactor, Kyoto, Japan
[10] Nihon Univ, Coll Ind Technol, Chiba, Japan
基金
日本学术振兴会;
关键词
atomic force microscope; solid state track detector; CR-39; contact X-ray microscopy; autoradiography; boron neutron; capture therapy;
D O I
10.1016/S0168-583X(01)01142-9
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
Soft X-ray microscopy using CR-39 plastic track detectors was demonstrated with an atomic force microscope (AFM) readout for the first time. A transmission X-ray image of the biological cells was recorded on the CR-39 surface, and revealed as relief after etching process. The resolution of the X-ray imaging is expected to be 100 nm or less, therefore imaging of biological cells is possible at an intracellular structure level. Using this technique, the high resolution image of both biological cells and charged particle tracks can be obtained simultaneously on a CR-39 with the AFM, In boron neutron capture therapy, this new technique provides the information on the distribution of boron compounds and radiation dose by charged particles mapping inside a cell. (C) 2002 Elsevier Science B.V. All rights reserved.
引用
收藏
页码:361 / 366
页数:6
相关论文
共 12 条
[1]   Ultra-high resolution radiography using CR-39 solid state track detectors and atomic force microscopy [J].
Amemiya, K ;
Takahashi, H ;
Nakazawa, M ;
Yasuda, N ;
Yamamoto, M ;
Nakagawa, Y ;
Kageji, T ;
Nakaichi, M ;
Ogura, K .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION B-BEAM INTERACTIONS WITH MATERIALS AND ATOMS, 1999, 159 (1-2) :75-80
[2]  
AMEMIYA K, 2000, IONIZING RAD, V26, P79
[3]   ATOMIC-FORCE MICROSCOPE STUDY OF ETCHED TRACKS OF LOW-ENERGY HEAVY-IONS IN MICA [J].
COLEMAN, RV ;
XUE, Q ;
GONG, Y ;
PRICE, PB .
SURFACE SCIENCE, 1993, 297 (03) :359-370
[4]   CLINICAL-RESULTS OF LONG-SURVIVING BRAIN-TUMOR PATIENTS WHO UNDERWENT BORON NEUTRON-CAPTURE THERAPY [J].
HATANAKA, H ;
NAKAGAWA, Y .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 1994, 28 (05) :1061-1066
[5]  
Henke B. L., 1982, Atomic Data and Nuclear Data Tables, V27, P1, DOI 10.1016/0092-640X(82)90002-X
[6]  
SHIMIZU H, 1996, XRAY MICROSCOPY SPEC, P157
[7]   A NOVEL-APPROACH TO THE MICRODOSIMETRY OF NEUTRON-CAPTURE THERAPY .1. HIGH-RESOLUTION QUANTITATIVE AUTORADIOGRAPHY APPLIED TO MICRODOSIMETRY IN NEUTRON-CAPTURE THERAPY [J].
SOLARES, GR ;
ZAMENHOF, RG .
RADIATION RESEARCH, 1995, 144 (01) :50-58
[8]   High resolution imaging for charged particles using CR-39 and atomic force microscopy [J].
Takahashi, H ;
Amemiya, K ;
Kaizuka, Y ;
Nakazawa, M ;
Yasuda, N ;
Yamamoto, M ;
Sakai, T ;
Kamiya, T ;
Okada, S .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1999, 422 (1-3) :751-755
[9]   3-DIMENSIONAL READOUT OF FLASH X-RAY IMAGES OF LIVING SPERM IN WATER BY ATOMIC-FORCE MICROSCOPY [J].
TOMIE, T ;
SHIMIZU, H ;
MAJIMA, T ;
YAMADA, M ;
KANAYAMA, T ;
KONDO, H ;
YANO, M ;
ONO, M .
SCIENCE, 1991, 252 (5006) :691-693
[10]   Atomic force microscopic analyses of heavy ion tracks in CR-39 [J].
Yamamoto, M ;
Yasuda, N ;
Kurano, M ;
Kanai, T ;
Furukawa, A ;
Ishigure, N ;
Ogura, K .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION B-BEAM INTERACTIONS WITH MATERIALS AND ATOMS, 1999, 152 (2-3) :349-356